20R0721 ROD AS Caterpillar parts
Rating:
Alternative (cross code) number:
CA20R0721
20R-0721
20R0721
CA20R0721
20R-0721
20R0721
Weight: 462 pounds 209 kg.
Information:
Table 8
"BOTTOM OUT LIFT CYLS"
" THEN PRESS [OK]"    
If the screen displays "RESULTS OK", proceed to Step 19. If the calibration has failed, proceed to Step 18.
Table 9
"RESULTS OK"
   
If the calibration passes, the screen displays "CALIBRATION COMPLETED OK". Proceed to Step 19.
Table 10
"CALIBRATION"
"COMPLETED OK"    
If the calibration has failed, the screen displays "CALIBRATION FAILED". Press the "OK" key for the reason of the failure.
Table 11
"CALIBRATION FAILED"
"PRESS [OK] FOR REASON"    
If the screen displays "LIFT LINKAGE SNSR ERR", the problem is with the sensor circuit. The lift linkage position sensor has one of the following conditions. no signal, wrong frequency, out of calibration and wiring problem. The problem must be repaired before the calibration can be completed. The display will advance. Then, press the "OK" key in order to acknowledge the error.
Table 12
"LIFT LINK SNSR ERR"
"CHECK SNSR/CAL/WIRING"    
Table 13
"PRESS [OK]"
"TO ACKNOWLEDGE"    
When the display shows "SENSOR ABOVE RANGE", the calibration indicates that the percent of duty cycle is above the specification. The lift linkage may not be moved to the correct range. The display will advance. Then, press the "OK" key in order to acknowledge the error.
Table 14
"SENSOR ABOVE RANGE"
"(65.0) XXX.X (92.0)"    
Table 15
"PRESS [OK]"
"TO ACKNOWLEDGE"    
When the display shows "SENSOR BELOW RANGE", the calibration indicates that the percent of duty cycle is below the specification. The lift linkage may not be moved to the correct range. The display will advance. Then, press the "OK" key in order to acknowledge the error.
Table 16
"SENSOR BELOW RANGE"
"(65.0) XXX.X% (92.0)"    
Table 17
"PRESS [OK]"
"TO ACKNOWLEDGE"    
If the calibration has failed, the screen will display "CALIBRATION FAILED". Press the "OK" key for the reason of the failure.
Table 18
"CALIBRATION FAILED"
"PRESS [>] FOR REASON"    
If the screen displays "LIFT LINKAGE SNSR ERR", the problem is with the sensor circuit. The lift linkage position sensor has one of the following conditions. no signal, wrong frequency, out of calibration and wiring problem. The problem must be repaired before the calibration can be completed. The display will advance. Then, press the "OK" key in order to acknowledge the error.
Table 19
"LIFT LINK SNSR ERR"
"CHECK SNSR/CAL/WIRING"    
Table 20
"PRESS [OK]"
"TO ACKNOWLEDGE"    
When the display shows "SENSOR ABOVE RANGE", the calibration indicates that the percent of duty cycle is above the specification. The tilt linkage may not be moved to the correct range. The display will advance. Then, press the "OK" key in order to acknowledge the error.
Table 21
"SENSOR ABOVE RANGE"
"8.0 XXX.X% (45.0)"    
Table 22
"PRESS [OK]"
"TO ACKNOWLEDGE"    
When the display shows "SENSOR BELOW RANGE", the calibration indicates that the percent of duty cycle is above the specification. The tilt linkage may not be moved to the correct range. The display will advance. Then, press the "OK" key in order to acknowledge the error.
Table 23
"SENSOR ABOVE RANGE"
"8.0 XXX.X% (45.0)"    
Table 24
"PRESS [OK]"
"TO ACKNOWLEDGE"    
After three seconds, the screen will display "EXITING CALIBRATION". After three seconds, exit the calibration.
Table 25
"EXITING"
"CALIBRATION"    Note: The lift linkage position sensor is calibrated.
Parts rod Caterpillar catalog:
20R0720
ROD AS
Caterpillar
Caterpillar
20R0717
ROD
Caterpillar
Caterpillar
20R0704
ROD AS
Caterpillar
Caterpillar
2099491
ROD END-FORK
Caterpillar
Caterpillar
2099448
ROD-CYLINDER
Caterpillar
Caterpillar
2099411
ROD-THREADED
Caterpillar
Caterpillar
20R2005
ROD AS-CONN
Caterpillar
Caterpillar
20R2004
ROD AS-CONN
Caterpillar
Caterpillar
20R2003
ROD AS-CONN
Caterpillar
Caterpillar
20R2002
ROD AS-CONN
Caterpillar
Caterpillar
20R0724
ROD AS
Caterpillar
Caterpillar
20R0723
ROD AS
Caterpillar
Caterpillar