4K1347 ROD-CONTROL Caterpillar parts
824S, 931B, 931C, 931C II, 933, 939, 988, D10, D10N, D11N, D3B, D3C, D3C II, D3C III, D4C, D4C III, D5C, D5C III, D8L, D9L, D9N
Rating:
Alternative (cross code) number:
CA4K1347
4K-1347
4K1347
CA4K1347
4K-1347
4K1347
Weight: 0.72 pounds 0 kg.
Information:
LENGTH
330.2
mm
THREAD LENGTH A
44.45
mm
THREAD LENGTH B
44.45
mm
THREAD SIZE A
.50-20
THREAD SIZE B
.50-20
TYPE
BOTH END
BULLDOZER, WHEEL LOADER,
Compatible equipment models: 4K1347:
Information:
Introduction
This Technical Information Bulletin provides additional information for the jacket water heaters, space heaters, and battery chargers that are used on the packages that are listed above.Problem
The contactors that are used for the jacket water heater, the space heater, and the battery charger are failing at very early hours.The contactors may be wired incorrectly. The incorrect wiring is due to the complexity of the product. Also, incomplete instructions that are provided for the wiring can lead to incorrect wiring. The contactor may have been ordered incorrectly because of the code that is used. The 240V L-L uses the "CNTHTR1" code. The 240V L-N uses the "CNTHTR2" code. The ordering system, that is also known as the "PSQ" or the "EOMP", had compatibility rule errors that allowed the selection of incompatible options when either the "CNTHTR1" or the "CNTHTR2" were selected.Solution
Now, the ordering system, that is also known as the "PSQ" or the "EOMP", only allows the selection of compatible options when either the "CNTHTR1" or the "CNTHTR2" are selected. Also, the price lists for the C15 and the C18 have updated text in order to describe the correct selection of the "CNTHTR1" or the "CNTHTR2". Verify the proper application of voltage before connecting the supply to the input power terminals of the control panel upon the commissioning procedure. First, check the voltage of the contactor. The voltage is stated on the contactor. Verify that the voltage that supplies power to the accessories of the genset matches the relay. Replace the contactor with the correct part number if the voltage does not match the relay. Refer to Table 1 for the correct part numbers.
Table 1
Part Number    Identifier    Rating    
169-0235     Contactor     110 VAC    
209-7301     Contactor     240 VAC    
This Technical Information Bulletin provides additional information for the jacket water heaters, space heaters, and battery chargers that are used on the packages that are listed above.Problem
The contactors that are used for the jacket water heater, the space heater, and the battery charger are failing at very early hours.The contactors may be wired incorrectly. The incorrect wiring is due to the complexity of the product. Also, incomplete instructions that are provided for the wiring can lead to incorrect wiring. The contactor may have been ordered incorrectly because of the code that is used. The 240V L-L uses the "CNTHTR1" code. The 240V L-N uses the "CNTHTR2" code. The ordering system, that is also known as the "PSQ" or the "EOMP", had compatibility rule errors that allowed the selection of incompatible options when either the "CNTHTR1" or the "CNTHTR2" were selected.Solution
Now, the ordering system, that is also known as the "PSQ" or the "EOMP", only allows the selection of compatible options when either the "CNTHTR1" or the "CNTHTR2" are selected. Also, the price lists for the C15 and the C18 have updated text in order to describe the correct selection of the "CNTHTR1" or the "CNTHTR2". Verify the proper application of voltage before connecting the supply to the input power terminals of the control panel upon the commissioning procedure. First, check the voltage of the contactor. The voltage is stated on the contactor. Verify that the voltage that supplies power to the accessories of the genset matches the relay. Replace the contactor with the correct part number if the voltage does not match the relay. Refer to Table 1 for the correct part numbers.
Table 1
Part Number    Identifier    Rating    
169-0235     Contactor     110 VAC    
209-7301     Contactor     240 VAC    
Caterpillar parts catalog:
Parts rod Caterpillar catalog:
5G3183
ROD
931B, 931C, 931C II, 933, 939, D3B, D3C, D3C II, D3C III, D4C, D4C III, D5C, D5C III
931B, 931C, 931C II, 933, 939, D3B, D3C, D3C II, D3C III, D4C, D4C III, D5C, D5C III
4H9098
ROD
931B, 931C, 931C II, 933, 939, D3B, D3C, D3C II, D3C III, D4C, D4C III, D5C, D5C III
931B, 931C, 931C II, 933, 939, D3B, D3C, D3C II, D3C III, D4C, D4C III, D5C, D5C III
1086404
ROD AS
933, 939, D3C III, D4C III, D5C III
933, 939, D3C III, D4C III, D5C III
5G0371
ROD
931B, 931C, 931C II, 933, 939, D3B, D3C, D3C II, D3C III, D4C, D4C III, D5C, D5C III
931B, 931C, 931C II, 933, 939, D3B, D3C, D3C II, D3C III, D4C, D4C III, D5C, D5C III
9P0073
ROD
910, 916, 926, 931B, 931C, 931C II, 933, 939, D3C III, D4B, D4C, D4C III, D4H, D4HTSK II, D5C, D5C III, IT18B, IT28, IT28B
910, 916, 926, 931B, 931C, 931C II, 933, 939, D3C III, D4B, D4C, D4C III, D4H, D4HTSK II, D5C, D5C III, IT18B, IT28, IT28B
8Y8907
ROD
933, 939, D3C III, D4C III, D5C III
933, 939, D3C III, D4C III, D5C III
8Y2952
ROD
D3C, D3C II, D3C III, D4C, D4C III, D5C, D5C III
D3C, D3C II, D3C III, D4C, D4C III, D5C, D5C III
8Y2342
ROD
D3C, D3C II, D3C III, D4C, D4C III, D5C, D5C III
D3C, D3C II, D3C III, D4C, D4C III, D5C, D5C III
8Y3047
ROD AS-LH
D3C, D3C II, D3C III, D4C, D4C III, D5C, D5C III
D3C, D3C II, D3C III, D4C, D4C III, D5C, D5C III
8Y3046
ROD AS
D3C, D3C II, D3C III, D4C, D4C III, D5C, D5C III
D3C, D3C II, D3C III, D4C, D4C III, D5C, D5C III
1100284
ROD
D3C III, D4C III, D5C III
D3C III, D4C III, D5C III
8Y5513
ROD
931C II, 933, 939, D3C II, D3C III, D4C III, D5C, D5C III, PS-300B, SM-350
931C II, 933, 939, D3C II, D3C III, D4C III, D5C, D5C III, PS-300B, SM-350