Diagnostic Trouble Codes for SCR Inducement Emergency Override
J1939 Code CDL Code Code Description
(code descriptions may vary) Comments
7343–31 E1598 (2) SCR Inducement Override Renewal Required This code indicates that the Inducement Override has been activated.
The code is logged.
Follow the troubleshooting procedure to identify the root cause of the fault. When an emergency situation occurs, initial activation of the override is allowed without input from Caterpillar™. Prior to activation, the operator will be notified of the following on display : "EMERGENCY USE ONLY. SEE OWNERS MANUAL. PENALTIES APPLY FOR MISUSE".Upon activation, the check engine, and action lamps will also illuminate to alert the operator that the override is active. A code will also become active indicating that the engine emission operator inducement emergency override is active. The code will remain active until the override is reset. The override must be paused by the operator if the emergency ends before the 120 hours of override operation has expired. While paused, the equipment will be subject to inducements (derates). The override may be reactivated if an emergency situation returns. After 120 hours of override use the override will expire, and the equipment will be subject to inducements. Upon activation, the check engine and action lamps will continue to be illuminated until the override is reset. If the override has expired, the dealer will need to reset the override to use the override again. The code indicating that the engine emission operator inducement emergency override is active, will be cleared when the override is reset. Resetting the override is the only way to clear the code.The override needs to be reset by an authorized dealer or distributor through the electronic service tool whenever the override has expired. The override cannot be used again until the override is reset. The warning lamp will continue to be illuminated until the override is reset. The override may be reset at any point after the initial activation.
Illustration 1 g06241919
Illustration 2 g06241920
Table 2
Troubleshooting Test Steps Values Results
1. Reset the Operator Inducement Emergency Override
A. Connect the electronic service tool to the diagnostic connector.
B. Under the "Service Tab", navigate to "Operator Inducement Emergency Override Timer Reset".
C. Click the "Reset" button at the bottom of the screen.
Reset
Result: The Emergency Inducement Operator Override Reset was performed.
Return the unit to service.
Parts roller Caterpillar catalog:
1231189
ROLLER GP-DFLG
Caterpillar
Caterpillar
1231188
ROLLER GP-DFLG
Caterpillar
Caterpillar
1231187
ROLLER GP SFLG
Caterpillar
Caterpillar
1231186
ROLLER GP-SFLG
Caterpillar
Caterpillar
1230429
ROLLER
Caterpillar
Caterpillar
1228653
ROLLER GP-
Caterpillar
Caterpillar
1247895
ROLLER
Caterpillar
Caterpillar
1244937
ROLLER GP-CARR
Caterpillar
Caterpillar
1235135
ROLLER AS
Caterpillar
Caterpillar
1235134
ROLLER AS
Caterpillar
Caterpillar
1231462
ROLLER AR
Caterpillar
Caterpillar
1231379
ROLLER GP-SFLG
Caterpillar
Caterpillar