Illustration 1 g02698976
Schematic of the Tilt Left Tip Back Solenoid
This diagnostic code is associated with the Tilt Left Tip Back Solenoid. The FMI 05 means that the ECM has detected that the current for the solenoid circuit is below normal.Conditions that cause this diagnostic code to be activated are:
The energize circuit of the solenoid is open.
The return circuit of the solenoid is open.
The solenoid has failed.
The ECM has failed. The failure of the ECM is unlikely. Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected.Note: Use a calibrated digital multimeter for the measurements in this procedure.System Response:The blade will not be able to tilt left or tip backward. The blade will still be able to tilt right and tip forward.Test Step 1. CHECK THE SOLENOID
Disconnect the solenoid from the machine harness.
At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire E921-PK(Pink)) to contact 2 (wire H716-WH(White)).
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the CID 0498 FMI 05 diagnostic code.Expected Result:The CID 0498 FMI 05 diagnostic code is no longer active. A CID 0498 FMI 06 diagnostic code becomes active when the jumper wire is connected.Results:
YES - The CID 0498 FMI 05 diagnostic code is no longer active. A CID 0498 FMI 06 diagnostic code becomes active when the jumper wire is connected. The solenoid has failed.Repair: Repeat this Test Step "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the problem.STOP
NO - The CID 0498 FMI 05 diagnostic code remains active. The jumper wire does not affect the status of the active diagnostic code. The solenoid is not causing the problem. Proceed to Test Step 2.Test Step 2. CHECK THE CIRCUIT FOR AN OPENThe jumper wire that was installed in the previous Test Step remains in place.
Turn the disconnect switch and the key start switch to the OFF position.
Disconnect the machine harness ECM connector J1 from the ECM.
At the machine harness connector J1 for the ECM, measure the resistance from contact J1-51 (wire E921-PK(Pink)) to contact J1-50 (wire H716-WH(White)).
While observing the multimeter resistance measurement, wiggle the machine harness connectors for the ECM and wiggle the machine harness connector for the solenoid. Gently pull on the wires and move the wires around.Expected Result:The resistance measurement is
Caterpillar parts catalog:
Parts roof Caterpillar catalog:
4780550
ROOF GP-CAB
Caterpillar
Caterpillar
3949524
ROOF AS
Caterpillar
Caterpillar
3899275
ROOF GP-CAB
Caterpillar
Caterpillar
5095956
ROOF AS
Caterpillar
Caterpillar
4578680
ROOF AS
Caterpillar
Caterpillar
4797418
ROOF GP-CAB
Caterpillar
Caterpillar
5081052
ROOF AS
Caterpillar
Caterpillar
4612622
ROOF
Caterpillar
Caterpillar
4578582
ROOF AS
Caterpillar
Caterpillar
3595373
ROOF AS
Caterpillar
Caterpillar
5462987
ROOF GP-CAB
Caterpillar
Caterpillar
5462944
ROOF AS
Caterpillar
Caterpillar