3905228 ROPS GP Caterpillar parts
Rating:
Alternative (cross code) number:
CA3905228
390-5228
3905228
CA3905228
390-5228
3905228
Information:
Removal Procedure
The Power Train Electric Drive System and the Accessory Power System will contain hazardous voltage levels during machine operation and for a period of time after machine shutdown.Do not remove any covers that will expose energized electrical components while the engine is operating. Do not remove any covers that will expose the energized electrical components while the components remain energized following an engine shutdown.Do not perform any type of electrical maintenance on the orange hazardous voltage conductors, the power train components or the accessory power system components while the engine is operating.Do not perform any type of electrical maintenance on the orange hazardous voltage conductors, the power train components or the accessory power system components while the components remain energized following an engine shutdown.Always perform the safe shutdown and de-energizing procedure before performing electrical service on the Power Train Electric Drive System or the Accessory Power System.Failure to follow these instructions could result in personal injury or death.
The two top compartments on the front of the Inverter Cabinet contain low voltage control components. All of the other compartments in the cabinet contain high voltage components. The "Electrical Shutdown and Voltage Discharge" procedure must be performed before any of the high voltage compartments are entered.
Prepare the machine for maintenance. Refer to Operation and Maintenance Manual, "Prepare the Machine for Maintenance".
Shutdown and de-energizing the machine. Refer to Operation and Maintenance Manual, "Electrical Shutdown and Voltage Discharge".
Illustration 1 g03795856
Remove cover assembly (1).
Illustration 2 g03795861
Motor 1
Illustration 3 g06361570Note: Note the current direction that is indicated on the top of current sensor (4), sensor assembly (5), and sensor assembly (6) for installation purposes.
Remove bolts (9) and washers (10). Remove bolts (12) and washers (13). Remove bus bar (11). Disconnect harness assembly (2). Remove screws (3). Remove sensor assembly (4). Repeat this step for sensor assembly (5) and sensor assembly (6).
Illustration 4 g03795956
Motor 2
Illustration 5 g03795957
Generator
Repeat Step 4 through step for sensor assemblies (7) and (8)Installation Procedure
Install sensor assemblies (8), sensor assemblies (7), sensor assembly (6), sensor assembly (5), and sensor assembly (4) in the reverse order of removal.
Tighten screws (3) to a torque of 3.5 0.5 N m (31 4 lb in).
Tighten bolts (9) and bolts (12) to a torque of 27.5 N m (243 lb in)
The Power Train Electric Drive System and the Accessory Power System will contain hazardous voltage levels during machine operation and for a period of time after machine shutdown.Do not remove any covers that will expose energized electrical components while the engine is operating. Do not remove any covers that will expose the energized electrical components while the components remain energized following an engine shutdown.Do not perform any type of electrical maintenance on the orange hazardous voltage conductors, the power train components or the accessory power system components while the engine is operating.Do not perform any type of electrical maintenance on the orange hazardous voltage conductors, the power train components or the accessory power system components while the components remain energized following an engine shutdown.Always perform the safe shutdown and de-energizing procedure before performing electrical service on the Power Train Electric Drive System or the Accessory Power System.Failure to follow these instructions could result in personal injury or death.
The two top compartments on the front of the Inverter Cabinet contain low voltage control components. All of the other compartments in the cabinet contain high voltage components. The "Electrical Shutdown and Voltage Discharge" procedure must be performed before any of the high voltage compartments are entered.
Prepare the machine for maintenance. Refer to Operation and Maintenance Manual, "Prepare the Machine for Maintenance".
Shutdown and de-energizing the machine. Refer to Operation and Maintenance Manual, "Electrical Shutdown and Voltage Discharge".
Illustration 1 g03795856
Remove cover assembly (1).
Illustration 2 g03795861
Motor 1
Illustration 3 g06361570Note: Note the current direction that is indicated on the top of current sensor (4), sensor assembly (5), and sensor assembly (6) for installation purposes.
Remove bolts (9) and washers (10). Remove bolts (12) and washers (13). Remove bus bar (11). Disconnect harness assembly (2). Remove screws (3). Remove sensor assembly (4). Repeat this step for sensor assembly (5) and sensor assembly (6).
Illustration 4 g03795956
Motor 2
Illustration 5 g03795957
Generator
Repeat Step 4 through step for sensor assemblies (7) and (8)Installation Procedure
Install sensor assemblies (8), sensor assemblies (7), sensor assembly (6), sensor assembly (5), and sensor assembly (4) in the reverse order of removal.
Tighten screws (3) to a torque of 3.5 0.5 N m (31 4 lb in).
Tighten bolts (9) and bolts (12) to a torque of 27.5 N m (243 lb in)
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts rops Caterpillar catalog:
3622674
ROPS AS
Caterpillar
Caterpillar
4878611
ROPS GP
Caterpillar
Caterpillar
4878607
ROPS GP
Caterpillar
Caterpillar
4878604
ROPS GP
Caterpillar
Caterpillar
4850332
ROPS GP
Caterpillar
Caterpillar
4802122
ROPS GP
Caterpillar
Caterpillar
4856085
ROPS GP
Caterpillar
Caterpillar
4592309
ROPS AS
Caterpillar
Caterpillar
4481921
ROPS GP
Caterpillar
Caterpillar
4174480
ROPS & PLATFORM GP
Caterpillar
Caterpillar
4174470
ROPS AS
Caterpillar
Caterpillar
3910180
ROPS GP-ENCLOSED
Caterpillar
Caterpillar