Illustration 1 g01269303
Circle Left Solenoid connections
This diagnostic code is associated with the circle left solenoid. The FMI 06 means that the Implement ECM 2 has determined that the current of the solenoid circuit is above normal. The Implement ECM 2 communicates this condition to the Implement ECM over the J1939 data link and the Implement ECM will activate this diagnostic code.The Implement ECM 2 provides a PWM output signal to the solenoid in order to provide proportional control of the solenoid. The ECM will vary the electrical current of the PWM output signal based on the input command that is received from the circle drive position sensor that is located in the right joystick assembly.Some possible causes of this diagnostic code are listed:
The energize circuit of the solenoid is shorted to ground.
The solenoid has failed.
The ECM has failed. This is unlikely. Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Note: The resistance of the solenoid coil should be 8.7 .4 ohms at 25 °C (77.0 °F).Test Step 1. CHECK THE SOLENOID
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the solenoid with the active diagnostic code from the machine harness. Expected Result:The active CID 2167 FMI 06 diagnostic code changes to a CID 2167 FMI 05 diagnostic code when the solenoid is disconnected.Results:
YES - The active CID 2167 FMI 06 diagnostic code changes to a CID 2167 FMI 05 diagnostic code when the solenoid is disconnected. The circuit is correct.Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid.STOP
NO - The CID 2167 FMI 06 remains active when the solenoid is disconnected. The solenoid is not causing the problem. Proceed
Caterpillar parts catalog:
Parts screen Caterpillar catalog:
1588988
SCREEN GP-HYDRAULIC
320C, 320C FM, 320C L, 322C, 322C FM, 325C, 325C FM, 330C, 330C FM, 330C L, 330C MH, M325C MH
320C, 320C FM, 320C L, 322C, 322C FM, 325C, 325C FM, 330C, 330C FM, 330C L, 330C MH, M325C MH
2590922
SCREEN GP-HYDRAULIC
320C, 320C FM, 320C L, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320D2, 322C, 322C FM, 323D L, 323D LN, 323D SA, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325C, 325C FM, 325D, 325D FM, 325D FM LL, 32...
320C, 320C FM, 320C L, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320D2, 322C, 322C FM, 323D L, 323D LN, 323D SA, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325C, 325C FM, 325D, 325D FM, 325D FM LL, 32...
1948247
SCREEN GP-HYDRAULIC
318C, 319C
318C, 319C
1195398
SCREEN-FILTER
312C, 312C L, 315C, 318C, 319C, 320B, 320C, 320C FM, 320C L, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320D2, 320D2 GC, 320D2 L, 320E, 320E L, 320E LN, 320E LRR, 320E RR,...
312C, 312C L, 315C, 318C, 319C, 320B, 320C, 320C FM, 320C L, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320D2, 320D2 GC, 320D2 L, 320E, 320E L, 320E LN, 320E LRR, 320E RR,...
1968187
SCREEN AS
318C, 319C, 320C, 320C FM
318C, 319C, 320C, 320C FM
2096000
SCREEN AS
318C, 320C, 320C FM, 320C L, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320D2, 320D2 GC, 320D2 L, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 322C, 322C FM, 323D L, 323D LN, 323D SA, 323D2 L, 323E L, 324D...
318C, 320C, 320C FM, 320C L, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320D2, 320D2 GC, 320D2 L, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 322C, 322C FM, 323D L, 323D LN, 323D SA, 323D2 L, 323E L, 324D...
1838104
SCREEN AS
318C, 319C, 320C
318C, 319C, 320C
1838117
SCREEN AS
318C, 319C, 320C
318C, 319C, 320C
1951805
SCREEN
318C, 320C
318C, 320C
1589107
SCREEN AS
318C, 319C, 325C
318C, 319C, 325C
1058096
SCREEN
1090, 1190, 1190T, 1290T, 1390, 2290, 2390, 2391, 2491, 2590, 315B FM L, 320B FM LL, 320C FM, 322B L, 322C, 322C FM, 325B L, 325C FM, 330B L, 330C FM, 345C, 511, 521, 521B, 522, 522B, 532, 541, 541 2,...
1090, 1190, 1190T, 1290T, 1390, 2290, 2390, 2391, 2491, 2590, 315B FM L, 320B FM LL, 320C FM, 322B L, 322C, 322C FM, 325B L, 325C FM, 330B L, 330C FM, 345C, 511, 521, 521B, 522, 522B, 532, 541, 541 2,...
1838105
SCREEN AS
320C
320C
2041019
SCREEN AS
314C
314C
2041018
SCREEN AS
314C
314C
2041017
SCREEN AS
314C
314C
2107972
SCREEN AS
308C
308C
2013775
SCREEN AS
308C
308C
2013774
SCREEN AS
308C
308C
1589107
SCREEN AS
318C, 319C, 325C
318C, 319C, 325C
1951805
SCREEN
318C, 320C
318C, 320C
1838117
SCREEN AS
318C, 319C, 320C
318C, 319C, 320C
1838104
SCREEN AS
318C, 319C, 320C
318C, 319C, 320C
2096000
SCREEN AS
318C, 320C, 320C FM, 320C L, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320D2, 320D2 GC, 320D2 L, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 322C, 322C FM, 323D L, 323D LN, 323D SA, 323D2 L, 323E L, 324D...
318C, 320C, 320C FM, 320C L, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320D2, 320D2 GC, 320D2 L, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 322C, 322C FM, 323D L, 323D LN, 323D SA, 323D2 L, 323E L, 324D...
1968187
SCREEN AS
318C, 319C, 320C, 320C FM
318C, 319C, 320C, 320C FM