1M2710 SCREEN Caterpillar parts
D8H, D9G
Rating:
Alternative (cross code) number:
CA1M2710
1M-2710
1M2710
CA1M2710
1M-2710
1M2710
Weight: 0.50 pounds 0 kg.
TRACK-TYPE TRACTOR,
Information:
This diagnostic code is associated with the Auxiliary Fourth Function (Thumbroller) Position Sensor. The position sensor provides a PWM input signal to the Implement ECM. If the duty cycle is outside calibration by 6%, but is still within acceptable range, an FMI 13diagnostic code will be activated.The sensor is a PWM sensor that operates at a frequency of approximately 500 100 Hz. The duty cycle of the PWM signal that is supplied to the ECM is measured in small increments. The changes in the duty cycle of the sensor cannot be measured with a digital multimeter.Test Step 1. CALIBRATION
Perform the calibration procedure for the sensor. Refer to the Testing and Adjusting, "Calibration" Story in this manual for the correct calibration procedure. Expected Result:The calibration procedure was performed successfully.Results:
OK - The calibration procedure was performed successfully. Resume normal machine operationSTOP
NOT OK - The calibration was not successful.Repair: Repeat the calibration procedure for the sensor.If the second calibration procedure is not successful, replace the position sensor.After sensor replacement, refer to the Testing and Adjusting, "Calibration" Story in this manual for the correct procedure. If the problem is still present after replacement and calibration of the new sensor, the ECM may have failed.Prior to replacing an ECM, always contact the Technical Communicator at your dealership for possible consultation with Caterpillar. This consultation may effect repair time. If the cause of the diagnostic code is not found, replace the ECM. Refer to the Testing and Adjusting, "Electronic Control Module (ECM) - Replace" Story in this manual for additional information.STOP
Perform the calibration procedure for the sensor. Refer to the Testing and Adjusting, "Calibration" Story in this manual for the correct calibration procedure. Expected Result:The calibration procedure was performed successfully.Results:
OK - The calibration procedure was performed successfully. Resume normal machine operationSTOP
NOT OK - The calibration was not successful.Repair: Repeat the calibration procedure for the sensor.If the second calibration procedure is not successful, replace the position sensor.After sensor replacement, refer to the Testing and Adjusting, "Calibration" Story in this manual for the correct procedure. If the problem is still present after replacement and calibration of the new sensor, the ECM may have failed.Prior to replacing an ECM, always contact the Technical Communicator at your dealership for possible consultation with Caterpillar. This consultation may effect repair time. If the cause of the diagnostic code is not found, replace the ECM. Refer to the Testing and Adjusting, "Electronic Control Module (ECM) - Replace" Story in this manual for additional information.STOP
Caterpillar parts catalog:
Parts screen Caterpillar catalog:
1013569
SCREEN
836
836
9W9114
SCREEN AS
D10N, D9N
D10N, D9N
4T9302
SCREEN
D10N, D8L, D9L
D10N, D8L, D9L
7T8307
SCREEN AS
D9L
D9L
6T7657
SCREEN AS
D8L
D8L
8D5489
SCREEN AS
120G, 12G, 130G, 140G, 14G, 160G, 16G
120G, 12G, 130G, 140G, 14G, 160G, 16G
8D3502
SCREEN AS
120G, 12G, 130G, 140G, 14G, 160G
120G, 12G, 130G, 140G, 14G, 160G
8D3501
SCREEN AS
120G, 12G, 130G, 140G, 14G, 160G
120G, 12G, 130G, 140G, 14G, 160G
RD103490
SCREEN
D7G
D7G
8M7152
SCREEN
D8H
D8H
5M5811
SCREEN
D8H
D8H