0991774 SCREW SET Caterpillar parts
307, E110, E70, E70B
Rating:
Alternative (cross code) number:
CA0991774
099-1774
0991774
CA0991774
099-1774
0991774
Weight: 0.07 pounds 0 kg.
EXCAVATOR, MINI HYD EXCAVATOR,
Information:
Before performing this maintenance, determine the type of coolant that is being used. This maintenance applies ONLY to cooling systems that are filled with Caterpillar Extended Life Coolant (ELC).Only clean water is needed in order to clean and flush the cooling system when ELC is drained and replaced.Drain the Coolant
1. Stop the engine and allow the engine to cool. Loosen the radiator filler cap slowly to relieve any pressure. Remove the radiator filler cap.2. Remove the cooling system drain plug(s) or open the drain valve. Open the cab heater valve to drain coolant from the cab heater. Remove the drain plug from the bottom of the water pump housing. Remove the drain plug from the bottom of the radiator. Allow the coolant to drain.
Dispose of used the coolant properly or recycle the used coolant. Various methods have been proposed for reclaiming used coolant for reuse in engine cooling systems. The full distillation procedure is the only method acceptable by Caterpillar for reclaiming the used coolant. Consult your Caterpillar dealer for information regarding the disposal and recycling of used coolant.
For information regarding disposal and recycling of used coolant, call the Caterpillar Service Technology Group:Outside Illinois: 1-800-542-TOOLInside Illinois: 1-800-541-TOOLCanada: 1-800-523-TOOLFlush the Cooling System
1. Flush the cooling system with clean water to remove any debris.2. Clean and install the drain plugs. Close the drain valve.3. Fill the cooling system with clean water. Install the radiator filler cap. Operate the engine until the jacket water temperature reaches 49 to 66°C (150 to 120°F).4. Stop the engine and allow the engine to cool. Loosen the radiator filler cap slowly to relieve any pressure. Remove the radiator filler cap. Remove the cooling system drain plugs. Open the drain valve. Allow the water to drain. Flush the cooling system with clean water.5. Repeat steps 3 and 4.Fill the Cooling System
Fill the cooling system no faster than 19 L (5 US gal) per minute to avoid air locks.
1. Install the drain plugs. Close the drain valve. Fill the cooling system with ELC. Refer to the Refill Capacities chart for the amount of ELC needed to refill the cooling system.2. Start and run the engine with the radiator filler cap removed. Allow the ELC to warm, the water temperature regulator to open, and the coolant level to stabilize. Add ELC if necessary in order to bring the coolant to the proper level.3. Check the condition of the radiator filler cap. If the gaskets are damaged, replace the old radiator filler cap with a new radiator filler cap. If the gaskets are not damaged, pressure test the radiator filler cap with a 9S-8140 Pressurized Pump Group (available from your Caterpillar dealer). The correct pressure is stamped on the face of the radiator filler cap. If the radiator filler cap does not hold the correct pressure, install a new radiator filler cap.4. Start the engine. Inspect for coolant leaks and proper operating temperature.
1. Stop the engine and allow the engine to cool. Loosen the radiator filler cap slowly to relieve any pressure. Remove the radiator filler cap.2. Remove the cooling system drain plug(s) or open the drain valve. Open the cab heater valve to drain coolant from the cab heater. Remove the drain plug from the bottom of the water pump housing. Remove the drain plug from the bottom of the radiator. Allow the coolant to drain.
Dispose of used the coolant properly or recycle the used coolant. Various methods have been proposed for reclaiming used coolant for reuse in engine cooling systems. The full distillation procedure is the only method acceptable by Caterpillar for reclaiming the used coolant. Consult your Caterpillar dealer for information regarding the disposal and recycling of used coolant.
For information regarding disposal and recycling of used coolant, call the Caterpillar Service Technology Group:Outside Illinois: 1-800-542-TOOLInside Illinois: 1-800-541-TOOLCanada: 1-800-523-TOOLFlush the Cooling System
1. Flush the cooling system with clean water to remove any debris.2. Clean and install the drain plugs. Close the drain valve.3. Fill the cooling system with clean water. Install the radiator filler cap. Operate the engine until the jacket water temperature reaches 49 to 66°C (150 to 120°F).4. Stop the engine and allow the engine to cool. Loosen the radiator filler cap slowly to relieve any pressure. Remove the radiator filler cap. Remove the cooling system drain plugs. Open the drain valve. Allow the water to drain. Flush the cooling system with clean water.5. Repeat steps 3 and 4.Fill the Cooling System
Fill the cooling system no faster than 19 L (5 US gal) per minute to avoid air locks.
1. Install the drain plugs. Close the drain valve. Fill the cooling system with ELC. Refer to the Refill Capacities chart for the amount of ELC needed to refill the cooling system.2. Start and run the engine with the radiator filler cap removed. Allow the ELC to warm, the water temperature regulator to open, and the coolant level to stabilize. Add ELC if necessary in order to bring the coolant to the proper level.3. Check the condition of the radiator filler cap. If the gaskets are damaged, replace the old radiator filler cap with a new radiator filler cap. If the gaskets are not damaged, pressure test the radiator filler cap with a 9S-8140 Pressurized Pump Group (available from your Caterpillar dealer). The correct pressure is stamped on the face of the radiator filler cap. If the radiator filler cap does not hold the correct pressure, install a new radiator filler cap.4. Start the engine. Inspect for coolant leaks and proper operating temperature.
Caterpillar parts catalog:
Parts screw Caterpillar catalog:
1184061
SCREW
307
307
0952218
SCREW
307, E120, E140
307, E120, E140
0968804
SCREW
307, D3G, D4C III, D4G, D5G, E120, E140, E70, E70B
307, D3G, D4C III, D4G, D5G, E120, E140, E70, E70B
0952234
SCREW
307, D3G, D4C III, D4G, D5G, E120, E140, E70
307, D3G, D4C III, D4G, D5G, E120, E140, E70
0968819
SCREW
307, E70, E70B
307, E70, E70B
3C2561
SCREW
307
307
7I6629
SCREW AS
307B
307B
7I6624
SCREW-TAPPING
307B
307B
4I9597
SCREW
307, E70B
307, E70B
0980823
SCREW
315
315
1280580
SCREW
315
315
1120163
SCREW
307
307