Continuity Check of the Glow Plugs
Table 1
Required Tools
Part Number Part Name Qty
6V-7070 Digital Multimeter 1 The following test will check the continuity of the glow plugs.
Disconnect the power supply and the bus bar.
Set the 6V-7070 Digital Multimeter to check continuity (resistance). Turn the audible signal on the digital multimeter ON.
Place one probe on the connection for the glow plug and the other probe to a suitable ground. The Digital Multimeter should make an audible sound. Replace the glow plug if there is no continuity.
Check the continuity on all the glow plugs. Checking The Operation of The Glow Plug
Table 2
Required Tools
Part Number Part Name Qty
225-8266 Ammeter 1
6V-7070 Digital Multimeter 1 The following test will check the operation of the glow plugs.
Disconnect the power supply and the bus bar.
Connect the power supply to only one glow plug.
Place the 225-8266 Ammeter on the power supply wire.
Connect the 6V-7070 Digital Multimeter to the terminal on the glow plug and to a suitable ground.
Turn the switch to the ON position in order to activate the glow plugs.
Table 3
12 Volt System
Amp Time (sec)
30 Initial
21 4
14 8
10 20
9 60
Table 4
24 Volt System
Amp Time (sec)
12 Initial
8.5 8
7 20
6 60
Check the reading on all of the glow plugs.
If there is no reading on the ammeter check the electrical connections. If the readings on the ammeter are low replace the glow plugs. If there is still no reading replace the glow plugs.
Table 1
Required Tools
Part Number Part Name Qty
6V-7070 Digital Multimeter 1 The following test will check the continuity of the glow plugs.
Disconnect the power supply and the bus bar.
Set the 6V-7070 Digital Multimeter to check continuity (resistance). Turn the audible signal on the digital multimeter ON.
Place one probe on the connection for the glow plug and the other probe to a suitable ground. The Digital Multimeter should make an audible sound. Replace the glow plug if there is no continuity.
Check the continuity on all the glow plugs. Checking The Operation of The Glow Plug
Table 2
Required Tools
Part Number Part Name Qty
225-8266 Ammeter 1
6V-7070 Digital Multimeter 1 The following test will check the operation of the glow plugs.
Disconnect the power supply and the bus bar.
Connect the power supply to only one glow plug.
Place the 225-8266 Ammeter on the power supply wire.
Connect the 6V-7070 Digital Multimeter to the terminal on the glow plug and to a suitable ground.
Turn the switch to the ON position in order to activate the glow plugs.
Table 3
12 Volt System
Amp Time (sec)
30 Initial
21 4
14 8
10 20
9 60
Table 4
24 Volt System
Amp Time (sec)
12 Initial
8.5 8
7 20
6 60
Check the reading on all of the glow plugs.
If there is no reading on the ammeter check the electrical connections. If the readings on the ammeter are low replace the glow plugs. If there is still no reading replace the glow plugs.
Parts screw Caterpillar catalog:
3850753
SCREW-
Caterpillar
Caterpillar
3850752
SCREW-
Caterpillar
Caterpillar
3850751
SCREW-
Caterpillar
Caterpillar
3850750
SCREW-
Caterpillar
Caterpillar
3850749
SCREW AS-
Caterpillar
Caterpillar
3850748
SCREW-SET
Caterpillar
Caterpillar
3856627
SCREW
Caterpillar
Caterpillar
3856604
SCREW-CAP CARR
Caterpillar
Caterpillar
3850820
SCREW-DRIVE
Caterpillar
Caterpillar
3850757
SCREW-PTO CVR
Caterpillar
Caterpillar
3850756
SCREW
Caterpillar
Caterpillar
3850755
SCREW
Caterpillar
Caterpillar