Information:

This diagnostic code is associated with the Transmission Solenoid 2. The FMI 13 means that the ECM has determined that the solenoid valve needs calibration. Once the calibration for the Transmission Solenoid 2 has been performed successfully, this diagnostic code will disappear. This failure is active on a new ECM.Possible causes of this diagnostic code are listed below:
The solenoid has failed.
The ECM has been replaced or new software has been installed.
The ECM has failed.System Response:The machine response is listed below:
Shifting may be harsh or sluggish.Note: Ensure that you have repaired any condition that would cause other active diagnostic codes that are related to this solenoid. For example, the CID 1402 FMI 03 or FMI 05 are not active when the CID 1402 FMI 13 is active. If the other diagnostic codes are active, troubleshoot those codes first. Then perform this procedure.Note: Ensure that the diagnostic code of CID 1402 FMI 13 is active before performing this procedure.Test Step 1. CHECK THE CALIBRATION
Perform the calibration procedure. Refer to Testing and Adjusting, "Fill Time for the Transmission Clutch (Electronic Technician) - Calibrate" for the correct procedure. The following machine conditions are required for the calibration procedure to begin:
Transmission filter is NOT being bypassed
Transmission oil temp is greater than 40 °C (104 °F) for the engagement pressure calibration. Transmission oil temp is greater than 58 °C (136 °F) for the fill time calibration.
Engine speed is greater than 1800 RPM
Parking Brake is engaged
Gear selector is in neutral
Transmission output speed is 0 RPM
Observe the status of the CID 1402 FMI 13. Expected Result:The CID 1402 FMI 13 is active.Results:
YES - The CID 1402 FMI 13 is active. The diagnostic code has not been corrected. Verify that the correct software has been flashed into the ECM, or that the correct ECM is installed on the machine. Then repeat the calibration.Repair: If the diagnostic code is still active and the cause of the diagnostic code is not found replace the ECM. It is unlikely that the ECM has failed. Verify that the solenoid and associated circuits are correct before you replace the ECM.STOP
NO - The CID 1402 FMI 13 is not active. The calibration corrected the condition that caused the diagnostic code. Repair: Resume normal operation.STOP