1232939 SEAL-RING Caterpillar parts
776C, 776D, 777D, 777F
Rating:
Alternative (cross code) number:
CA1232939
123-2939
1232939
CA1232939
123-2939
1232939
Weight: 0.06 pounds 0 kg.
Information:
ID
407
mm
MATERIAL
Rubber
RADIAL HEIGHT
4.25
mm
CS<br>STYLE
Rect Sq
AXIAL WIDTH
2.75
TRACTOR, TRUCK,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$48.49
23 Mar 2023
US: WITHOUTHAMHEP
Replacement For Compatible With 1232939 Seal Ring Fits Caterpillar Models
PINOM
PINOM
Information:
System Operation Description:Most electrical problems are caused by poor connections. The following procedure will assist in detecting problems with connectors and with wiring. If a problem is found correct the condition and verify that the problem is resolved.Intermittent electrical problems are sometimes resolved by disconnecting and reconnecting connectors. It is very important to check for diagnostic codes immediately before disconnecting a connector. Also check for diagnostic codes after reconnecting the connector. If the status of a diagnostic code is changed due to disconnecting and reconnecting a connector, there are several possible reasons. The likely reasons are loose terminals, improperly crimped terminals, moisture, corrosion, and inadequate mating of a connection.Follow these guidelines:
Always use a 1U-5804 Crimp Tool to service Deutsch HD and DT connectors. Never solder the terminals onto the wires. Refer to Tool Operating Manual, SEHS9615, "Servicing Deutsch HD and DT Style Connectors".
Always use a 147-6456 Wedge Removal Tool to remove wedges from DT connectors. Never use a screwdriver to pry a wedge from a connector.
Always use a breakout harness for a voltmeter probe or a test light. Never break the insulation of a wire in order to access to a circuit for measurements.
If a wire is cut, always install a new terminal for the repair.
The connection of any electrical equipment and the disconnection of any electrical equipment may cause an explosion hazard which may result in injury or death. Do not connect any electrical equipment or disconnect any electrical equipment in an explosive atmosphere.
Test Step 1. Check Connectors for Moisture and Corrosion
Illustration 1 g01625736
(1) Leaky seal at the connector (typical example)
Inspect all wiring harnesses. Ensure that the routing of the wiring harness allows the wires to enter the face of each connector at a perpendicular angle. Otherwise, the wire will deform the seal bore. Refer to Illustration 1. This will create a path for the entrance of moisture. Verify that the seals for the wires are sealing correctly.
Illustration 2 g01625744
Diagram for the installation of a connector plug (typical example)
(2) Electronic Control Module (ECM) connector
(3) Correctly inserted plug
(4) Incorrectly inserted plug
Ensure that the sealing plugs are in place. If any of the plugs are missing, replace the plug. Ensure that the plugs are inserted correctly into the connector. Refer to Illustration 2.
Illustration 3 g01625748
(5) Seal for a three-pin connector (typical example)
Illustration 4 g01625752
(6) Seal for ECM connector (typical example)
Disconnect the suspect connector and inspect the connector seal. Ensure that the seals are in good condition. If necessary, replace the connector.
Thoroughly inspect the connectors for evidence of moisture entry. Note: It is normal to see some minor seal abrasion on connector seals. Minor seal abrasion will not allow the entry of moisture.If moisture or corrosion is evident in the connector, the source of the moisture entry must be found and the source of the moisture entry must be repaired. If the source of the moisture entry is not repaired, the problem will recur. Simply drying the connector will not fix the problem. Check the following items for the possible moisture entry
Always use a 1U-5804 Crimp Tool to service Deutsch HD and DT connectors. Never solder the terminals onto the wires. Refer to Tool Operating Manual, SEHS9615, "Servicing Deutsch HD and DT Style Connectors".
Always use a 147-6456 Wedge Removal Tool to remove wedges from DT connectors. Never use a screwdriver to pry a wedge from a connector.
Always use a breakout harness for a voltmeter probe or a test light. Never break the insulation of a wire in order to access to a circuit for measurements.
If a wire is cut, always install a new terminal for the repair.
The connection of any electrical equipment and the disconnection of any electrical equipment may cause an explosion hazard which may result in injury or death. Do not connect any electrical equipment or disconnect any electrical equipment in an explosive atmosphere.
Test Step 1. Check Connectors for Moisture and Corrosion
Illustration 1 g01625736
(1) Leaky seal at the connector (typical example)
Inspect all wiring harnesses. Ensure that the routing of the wiring harness allows the wires to enter the face of each connector at a perpendicular angle. Otherwise, the wire will deform the seal bore. Refer to Illustration 1. This will create a path for the entrance of moisture. Verify that the seals for the wires are sealing correctly.
Illustration 2 g01625744
Diagram for the installation of a connector plug (typical example)
(2) Electronic Control Module (ECM) connector
(3) Correctly inserted plug
(4) Incorrectly inserted plug
Ensure that the sealing plugs are in place. If any of the plugs are missing, replace the plug. Ensure that the plugs are inserted correctly into the connector. Refer to Illustration 2.
Illustration 3 g01625748
(5) Seal for a three-pin connector (typical example)
Illustration 4 g01625752
(6) Seal for ECM connector (typical example)
Disconnect the suspect connector and inspect the connector seal. Ensure that the seals are in good condition. If necessary, replace the connector.
Thoroughly inspect the connectors for evidence of moisture entry. Note: It is normal to see some minor seal abrasion on connector seals. Minor seal abrasion will not allow the entry of moisture.If moisture or corrosion is evident in the connector, the source of the moisture entry must be found and the source of the moisture entry must be repaired. If the source of the moisture entry is not repaired, the problem will recur. Simply drying the connector will not fix the problem. Check the following items for the possible moisture entry
Caterpillar parts catalog:
Parts seal Caterpillar catalog:
8J9449
SEAL-RING
777, 777B, 777D
777, 777B, 777D
8J9450
SEAL-RING
777, 777B, 777D
777, 777B, 777D
8J9916
SEAL-RING
777, 777B, 777D
777, 777B, 777D
8J9933
SEAL-RING
777, 777B, 777D
777, 777B, 777D
3232197
SEAL-U-CUP
776D, 777D, 777F
776D, 777D, 777F
2434572
SEAL-O-RING
776D, 777D, 777F, 777G
776D, 777D, 777F, 777G
5P4342
SEAL-O-RING
528, 528B, 530B, 773F, 773G, 773G LRC, 773G OEM, 775F, 775G, 775G LRC, 775G OEM, 777F, 777G
528, 528B, 530B, 773F, 773G, 773G LRC, 773G OEM, 775F, 775G, 775G LRC, 775G OEM, 777F, 777G
7Y0640
SEAL-O-RING
365B, 365B II, 365C, 365C L, 375, 375 L, 385B, 385C, 385C FS, 385C L, 385C L MH, 390D, 390D L, 390F L, 5080, 5090B, 773F, 773G, 773G LRC, 773G OEM, 775F, 775G, 775G LRC, 775G OEM, 777F, 777G
365B, 365B II, 365C, 365C L, 375, 375 L, 385B, 385C, 385C FS, 385C L, 385C L MH, 390D, 390D L, 390F L, 5080, 5090B, 773F, 773G, 773G LRC, 773G OEM, 775F, 775G, 775G LRC, 775G OEM, 777F, 777G
3654920
SEAL GP-DUO-CONE
773F, 773G, 773G LRC, 773G OEM, 775F, 775G, 775G LRC, 775G OEM, 777F, 777G, AD55, AD55B, AD60
773F, 773G, 773G LRC, 773G OEM, 775F, 775G, 775G LRC, 775G OEM, 777F, 777G, AD55, AD55B, AD60
9J5570
SEAL
777D, 777F
777D, 777F
1757894
SEAL-O-RING
777F
777F
3144120
SEAL GP-DUO-CONE
773B, 773D, 773E, 775B, 775D, 775E, 776C, 776D, 777D
773B, 773D, 773E, 775B, 775D, 775E, 776C, 776D, 777D
3144122
SEAL GP-DUO-CONE
770, 770G, 770G OEM, 772, 772G, 772G OEM, 776C, 777D, 777F, 777G, AD55, AD55B, AD60
770, 770G, 770G OEM, 772, 772G, 772G OEM, 776C, 777D, 777F, 777G, AD55, AD55B, AD60
2979546
SEAL GP-DUO-CONE
770, 772, 773B, 773D, 773E, 775B, 775D, 775E, 776C, 776D, 777D, 784B, 784C, 785B, 785C, 785D, 789B, 789C, 789D, 793B, 793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ
770, 772, 773B, 773D, 773E, 775B, 775D, 775E, 776C, 776D, 777D, 784B, 784C, 785B, 785C, 785D, 789B, 789C, 789D, 793B, 793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ
9D3976
SEAL
776C, 777, 777B
776C, 777, 777B
9X7711
SEAL GP
776C, 777B, 784B, 785, 785B, 789B, 793B
776C, 777B, 784B, 785, 785B, 789B, 793B
9W7206
SEAL GP-DUO CONE
784B, 789, 789B, 793, 793B, 793C
784B, 789, 789B, 793, 793B, 793C
4335904
SEAL-U-CUP
776C, 776D, 777D, 777F, 777G
776C, 776D, 777D, 777F, 777G
8T3542
SEAL-RING
776, 776C, 777B
776, 776C, 777B
6J7693
SEAL-RING
776, 776C, 776D, 777, 777B, 777D, 777F, 777G
776, 776C, 776D, 777, 777B, 777D, 777F, 777G
9T0279
SEAL
776C, 777, 777B
776C, 777, 777B
8T3541
SEAL-RING
776, 776C, 777B
776, 776C, 777B
1232940
SEAL-RING
776C, 776D, 777D, 777F
776C, 776D, 777D, 777F