1410713 SEAL-LIP TYPE Caterpillar parts
242B3, 242D, 246C, 252B, 252B3, 256C, 257B3, 257D, 259B3, 259D, 262C, 262C2, 262D, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 287D, 289C, 289C2, 289D, 297C, 299C, 302.5, 302.5C, 730, 902, TH350B, TH...
Rating:
Alternative (cross code) number:
CA1410713
141-0713
1410713
CA1410713
141-0713
1410713
Weight: 0.04 pounds 0 kg.
COMPACT TRACK LOADER, TELEHANDLER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
RAParts 1410713 -Universal Electric Throttle with Brackets for B&S Gas Engines
Reliable Aftermarket Parts OEM Numbers Are Provided for Reference Only. Please Verify Fit Prior To Ordering. || Please Note: Some Listings Use Stock Images for Reference and May Differ from the Actual Product. || This Aftermarket Part Is Made to Meet or Exceed Manufacturer (OEM) Specifications. || All OEM part numbers and logos are to be used for identification purposes only.
Reliable Aftermarket Parts OEM Numbers Are Provided for Reference Only. Please Verify Fit Prior To Ordering. || Please Note: Some Listings Use Stock Images for Reference and May Differ from the Actual Product. || This Aftermarket Part Is Made to Meet or Exceed Manufacturer (OEM) Specifications. || All OEM part numbers and logos are to be used for identification purposes only.
Buyers Products, SAM Universal Electric Throttle With Brackets, Included (qty.) 1 Model# 1410713
Buyers Products Company SAM Universal Electric Throttle Motor is available stand-alone, or with to operate a Briggs and Stratton Gas Engine.
Buyers Products Company SAM Universal Electric Throttle Motor is available stand-alone, or with to operate a Briggs and Stratton Gas Engine.
RAParts 1410713 -Universal Electric Throttle with Brackets for B&S Gas Engines
Reliable Aftermarket Parts OEM Numbers Are Provided for Reference Only. Please Verify Fit Prior To Ordering. || Please Note: Some Listings Use Stock Images for Reference and May Differ from the Actual Product. || This Aftermarket Part Is Made to Meet or Exceed Manufacturer (OEM) Specifications. || All OEM part numbers and logos are to be used for identification purposes only.
Reliable Aftermarket Parts OEM Numbers Are Provided for Reference Only. Please Verify Fit Prior To Ordering. || Please Note: Some Listings Use Stock Images for Reference and May Differ from the Actual Product. || This Aftermarket Part Is Made to Meet or Exceed Manufacturer (OEM) Specifications. || All OEM part numbers and logos are to be used for identification purposes only.
1410713
Images:
Information:
Chapter 3. Operation and Adjustment
Initial Pre-Start Settings
-READ FULL PROCEDURERead this entire procedure before starting the prime mover.
CAUTION-DO NOT TURN POTS BEYOND THEIR STOPSThe Rated Speed Potentiometer is the only multi-turn pot in this control. All other pots are single-turn. Take care not to turn these pots beyond their stops.
1. RATED SPEEDA. Set the RATED SPEED potentiometer to minimum (fully counterclockwise).B. Set the external Speed Trim, if used, to mid-position.2. RESET- Set at mid-position.3. GAIN- Set at mid-position.4. RAMP TIME- Set at maximum (fully clockwise- be careful not to overtorque the pot ).5. LOW IDLE SPEED- Set at maximum (fully clockwise- be careful not to overtorque the pot ).6. LOAD GAIN- Set at mid-position.7. DROOP- Set at minimum (fully counterclockwise- be careful not to overtorque the pot ).8. ACTUATOR COMPENSATION.A. Set the ACTUATOR COMPENSATION potentiometer at 2 on the 0 to 10 potentiometer scale for diesel, gas turbine, or fuel-injected gasoline prime movers.B. Set the ACTUATOR COMPENSATION potentiometer at 6 on the 0 to 10 potentiometer scale for carbureted-gas or gasoline prime movers, and steam turbines.9. START FUEL LIMIT- Set at maximum (fully clockwise- be careful not to overtorque the pot ).10. Be sure the actuator is connected to terminals 20 and 21.Start-up Adjustments
1. Complete the installation checkout procedure in Chapter 2, and the initial prestart settings above.
CAUTION-SPEED RANGE SWITCHBe sure the speed range switch is set on the right speed range for your application as described in Chapter 2.
2. Close the Close for Rated contact. Set the control for isochronous operation by closing the droop contact. This is for initial prime mover start-up only. For normal start-up, the Close For Rated contact (open for idle/close for rated) should be open if the prime mover is to start at idle.3. Apply input power to the control.4. Preset rated speed.If a signal generator is not used, set the RATED SPEED potentiometer at minimum (fully counterclockwise).When using a signal generator to set rated speed, set the signal generator for the frequency of the speed sensor at rated speed, and connect it to terminals 28 and 29. (The rated speed frequency in Hz equals the rated prime mover speed in rpm times the number of teeth on the speed-sensing gear divided by 60.) Put the Close For Rated contact in the rated (closed) position. Set the speed trim potentiometer, if used, to mid-position. Connect a dc analog voltmeter to terminals 20 (+) and 21 (-) to read actuator voltage.If the actuator voltage is at minimum (minimum will be approximately 0 volts), slowly turn the RATED SPEED potentiometer clockwise (counterclockwise for reverse-acting controls) until the voltage just begins to move to maximum.If the actuator voltage is at maximum, slowly turn the RATED SPEED potentiometer counterclockwise (clockwise for reverse-acting controls) until the voltage just begins to move to minimum.Continue to very slowly adjust the RATED SPEED potentiometer in the appropriate direction, trying to stop the actuator voltage between the minimum and maximum voltages. Because it is not possible to stop the motion, cease adjusting
Initial Pre-Start Settings
-READ FULL PROCEDURERead this entire procedure before starting the prime mover.
CAUTION-DO NOT TURN POTS BEYOND THEIR STOPSThe Rated Speed Potentiometer is the only multi-turn pot in this control. All other pots are single-turn. Take care not to turn these pots beyond their stops.
1. RATED SPEEDA. Set the RATED SPEED potentiometer to minimum (fully counterclockwise).B. Set the external Speed Trim, if used, to mid-position.2. RESET- Set at mid-position.3. GAIN- Set at mid-position.4. RAMP TIME- Set at maximum (fully clockwise- be careful not to overtorque the pot ).5. LOW IDLE SPEED- Set at maximum (fully clockwise- be careful not to overtorque the pot ).6. LOAD GAIN- Set at mid-position.7. DROOP- Set at minimum (fully counterclockwise- be careful not to overtorque the pot ).8. ACTUATOR COMPENSATION.A. Set the ACTUATOR COMPENSATION potentiometer at 2 on the 0 to 10 potentiometer scale for diesel, gas turbine, or fuel-injected gasoline prime movers.B. Set the ACTUATOR COMPENSATION potentiometer at 6 on the 0 to 10 potentiometer scale for carbureted-gas or gasoline prime movers, and steam turbines.9. START FUEL LIMIT- Set at maximum (fully clockwise- be careful not to overtorque the pot ).10. Be sure the actuator is connected to terminals 20 and 21.Start-up Adjustments
1. Complete the installation checkout procedure in Chapter 2, and the initial prestart settings above.
CAUTION-SPEED RANGE SWITCHBe sure the speed range switch is set on the right speed range for your application as described in Chapter 2.
2. Close the Close for Rated contact. Set the control for isochronous operation by closing the droop contact. This is for initial prime mover start-up only. For normal start-up, the Close For Rated contact (open for idle/close for rated) should be open if the prime mover is to start at idle.3. Apply input power to the control.4. Preset rated speed.If a signal generator is not used, set the RATED SPEED potentiometer at minimum (fully counterclockwise).When using a signal generator to set rated speed, set the signal generator for the frequency of the speed sensor at rated speed, and connect it to terminals 28 and 29. (The rated speed frequency in Hz equals the rated prime mover speed in rpm times the number of teeth on the speed-sensing gear divided by 60.) Put the Close For Rated contact in the rated (closed) position. Set the speed trim potentiometer, if used, to mid-position. Connect a dc analog voltmeter to terminals 20 (+) and 21 (-) to read actuator voltage.If the actuator voltage is at minimum (minimum will be approximately 0 volts), slowly turn the RATED SPEED potentiometer clockwise (counterclockwise for reverse-acting controls) until the voltage just begins to move to maximum.If the actuator voltage is at maximum, slowly turn the RATED SPEED potentiometer counterclockwise (clockwise for reverse-acting controls) until the voltage just begins to move to minimum.Continue to very slowly adjust the RATED SPEED potentiometer in the appropriate direction, trying to stop the actuator voltage between the minimum and maximum voltages. Because it is not possible to stop the motion, cease adjusting
Cat SIS web machinery list:
Parts seal Caterpillar catalog:
2D2443
SEAL-O-RING
120M, 12M, 140M, 14M, 16, 160M, 16G, 16H, 16H NA, 16M, 611, 613, 613B, 613C, 613C II, 613G, 615, 615C, 650B, 666, 725, 725C, 730, 730C, 735, 735B, 740, 740B, 768B, 769, 814, 814B, 814F, 814F II, 824C,...
120M, 12M, 140M, 14M, 16, 160M, 16G, 16H, 16H NA, 16M, 611, 613, 613B, 613C, 613C II, 613G, 615, 615C, 650B, 666, 725, 725C, 730, 730C, 735, 735B, 740, 740B, 768B, 769, 814, 814B, 814F, 814F II, 824C,...
6S3018
SEAL-RING
518, 528, 613C, 613C II, 613G, 730, 910, 950B, 950B/950E, D300E, D300E II, R1300, R1300G, R1300G II
518, 528, 613C, 613C II, 613G, 730, 910, 950B, 950B/950E, D300E, D300E II, R1300, R1300G, R1300G II
9X3975
SEAL-RING
518, 528, 613C, 613C II, 613G, 725, 725C, 730, 730C, 950B, 950B/950E, 966C, D300E, D300E II, R1300, R1300G, R1300G II
518, 528, 613C, 613C II, 613G, 725, 725C, 730, 730C, 950B, 950B/950E, 966C, D300E, D300E II, R1300, R1300G, R1300G II
1932200
SEAL-LIP TYPE
120M, 120M 2, 12M, 12M 2, 12M 3, 12M 3 AWD, 140M, 140M 2, 140M 3, 140M 3 AWD, 160M, 160M 2, 160M 3, 160M 3 AWD, 24M, 525B, 525C, 525D, 535B, 535C, 535D, 545, 545C, 545D, 555D, 611, 613C II, 613G, 615C...
120M, 120M 2, 12M, 12M 2, 12M 3, 12M 3 AWD, 140M, 140M 2, 140M 3, 140M 3 AWD, 160M, 160M 2, 160M 3, 160M 3 AWD, 24M, 525B, 525C, 525D, 535B, 535C, 535D, 545, 545C, 545D, 555D, 611, 613C II, 613G, 615C...
1570741
SEAL-LIP TYPE
902, 906, 906H, 906H2, 907H, 907H2, 908, 908H, 908H2
902, 906, 906H, 906H2, 907H, 907H2, 908, 908H, 908H2
1973695
SEAL-LIP TYPE
902, 906, 906H, 906H2, 907H, 907H2, 908, 908H, 908H2
902, 906, 906H, 906H2, 907H, 907H2, 908, 908H, 908H2
1973696
SEAL-LIP TYPE
902, 906, 908
902, 906, 908
1570740
SEAL-LIP TYPE
902, 904H, 906, 906H, 906H2, 907H, 907H2, 908, 908H, 908H2, CS-323C
902, 904H, 906, 906H, 906H2, 907H, 907H2, 908, 908H, 908H2, CS-323C
5K0658
SEAL-LIP TYPE
902, 906, 908, 930
902, 906, 908, 930
5P8888
SEAL-LIP TYPE
120G, 902, 906, 908, 910
120G, 902, 906, 908, 910
9D6584
SEAL-LIP TYPE
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 14...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 14...
2934503
SEAL-LIP TYPE
725, 725C, 730, 730C, 735, 735B, 740, 740B
725, 725C, 730, 730C, 735, 735B, 740, 740B
2330617
SEAL-WIPER
450E, D6K, D6K LGP, D6K XL, D6K2, D6K2 LGP, TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
450E, D6K, D6K LGP, D6K XL, D6K2, D6K2 LGP, TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
1672297
SEAL-U-CUP
450E, D6K, D6K LGP, D6K XL, D6K2, D6K2 LGP, TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
450E, D6K, D6K LGP, D6K XL, D6K2, D6K2 LGP, TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
1617146
SEAL-PISTON
246C, 246D, 256C, 262C, 262C2, 262D, 272C, 272D, 272D XHP, 277C, 277C2, 277D, 279C, 279C2, 279D, 287C, 287C2, 287D, 289C, 289C2, 289D, 297C, 299C, 299D, 299D XHP, 302.5, 302.5C, 730, 902, TH350B, TH35...
246C, 246D, 256C, 262C, 262C2, 262D, 272C, 272D, 272D XHP, 277C, 277C2, 277D, 279C, 279C2, 279D, 287C, 287C2, 287D, 289C, 289C2, 289D, 297C, 299C, 299D, 299D XHP, 302.5, 302.5C, 730, 902, TH350B, TH35...
9X7298
SEAL AS
307B, 308C, 311, 311B, 311C, 311D LRR, 312, 312B, 312B L, 312C, 312C L, 312D, 312D L, 312E, 312E L, 313B, 313D, 314C, 314D CR, 314D LCR, 314E CR, 314E LCR, 315, 315B, 315B L, 315C, 315D L, 317, 317B L...
307B, 308C, 311, 311B, 311C, 311D LRR, 312, 312B, 312B L, 312C, 312C L, 312D, 312D L, 312E, 312E L, 313B, 313D, 314C, 314D CR, 314D LCR, 314E CR, 314E LCR, 315, 315B, 315B L, 315C, 315D L, 317, 317B L...
2273857
SEAL-PIN
TH350B, TH355B
TH350B, TH355B
2253286
SEAL-WIPER
539, 735, 735B, 740, 795F AC, 795F XQ, 797, 797B, 797F, 824G II, 824H, 834G, 834H, 836G, 836H, 854G, 950H, 966G, 966G II, 966H, 972G, 972G II, 972H, 980G, 980G II, 980H, AD30, D10R, D10T, D11N, D11R, ...
539, 735, 735B, 740, 795F AC, 795F XQ, 797, 797B, 797F, 824G II, 824H, 834G, 834H, 836G, 836H, 854G, 950H, 966G, 966G II, 966H, 972G, 972G II, 972H, 980G, 980G II, 980H, AD30, D10R, D10T, D11N, D11R, ...
2314431
SEAL-QUAD RING
301.5, TH220B, TH330B, TH340B, TH350B, TH355B
301.5, TH220B, TH330B, TH340B, TH350B, TH355B
8U2552
SEAL-O-RING
213B, 214B, 224B, M318, M320, TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
213B, 214B, 224B, M318, M320, TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
1864955
SEAL
TH350B, TH355B
TH350B, TH355B
1672318
SEAL-U-CUP
24M, 450E, 824K, 825K, 826K, 834K, D7E, D7E LGP, TH350B, TH355B, TH560B, TH580B
24M, 450E, 824K, 825K, 826K, 834K, D7E, D7E LGP, TH350B, TH355B, TH560B, TH580B
1659284
SEAL-LIP TYPE
307B, 307C, 307D, 308C, 311B, 311C, 311D LRR, 312B, 312B L, 312C, 312C L, 312D, 312D L, 312E, 312E L, 313B, 313D, 313D2, 314C, 314D CR, 314D LCR, 314E CR, 314E LCR, 450E, M313C, M313D, M315, M315C, M3...
307B, 307C, 307D, 308C, 311B, 311C, 311D LRR, 312B, 312B L, 312C, 312C L, 312D, 312D L, 312E, 312E L, 313B, 313D, 313D2, 314C, 314D CR, 314D LCR, 314E CR, 314E LCR, 450E, M313C, M313D, M315, M315C, M3...
1438914
SEAL-U-CUP
302.5, 302.5C, 63, 730, 902, TH350B, TH355B
302.5, 302.5C, 63, 730, 902, TH350B, TH355B