1472852 SEAL AS Caterpillar parts
D11R, D11T
Rating:
Alternative (cross code) number:
CA1472852
147-2852
1472852
CA1472852
147-2852
1472852
Weight: 8 pounds 4 kg.
TRACK-TYPE TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
For Whirlpool W10244343 Washer Cam-Agit 3947922 1472852 AH2350351 EA23503...
FOLIAGE For Whirlpool W10244343 Washer Cam-Agit 3947922 1472852 AH2350351 EA23503... || Enhance your washer's performance with the W10244343 camagit, designed to replace old or faulty 3947922 and 1472852 parts. || Ensure operation and efficient cleaning with this replacement part AH2350351 for washers, compatible with various models. || Simplify your cooking routine! Our trusted accessories keep your kitchen tools running smoothly. Double-check dimensions and photos for the right fit. || For a precise fit and wise selection. make sure to thoroughly check the product’s dimensions and review the accompanying photos.
FOLIAGE For Whirlpool W10244343 Washer Cam-Agit 3947922 1472852 AH2350351 EA23503... || Enhance your washer's performance with the W10244343 camagit, designed to replace old or faulty 3947922 and 1472852 parts. || Ensure operation and efficient cleaning with this replacement part AH2350351 for washers, compatible with various models. || Simplify your cooking routine! Our trusted accessories keep your kitchen tools running smoothly. Double-check dimensions and photos for the right fit. || For a precise fit and wise selection. make sure to thoroughly check the product’s dimensions and review the accompanying photos.
Information:
Illustration 1 g02025271
Schematic of the "Radiator Fan Speed Viscus" clutch
This diagnostic code is associated with the "Radiator Fan Speed Viscus" clutch. The FMI 06 diagnostic code means that the ECM has determined that there is a short to ground in the circuit. The possible causes of this diagnostic code are listed below:
The energize circuit of the clutch is shorted to ground.
The clutch has failed.
The ECM has failed. This is unlikely. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0362 FMI 06 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.Test Step 1. CHECK THE CLUTCH.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the "Fan Speed Viscus" clutch from the machine harness. Expected Result:The CID 0362 FMI 06 diagnostic code changes to a CID 0362 FMI 05 diagnostic code when the clutch is disconnected.Results:
YES - The CID 0362 FMI 06 diagnostic code changes to a CID 0362 FMI 05 diagnostic code when the clutch is disconnected. The circuit is correct.Repair: The clutch has failed. Repeat this test "CHECK THE CLUTCH" in order to verify the clutch failure. Replace the clutch.STOP
NO - The CID 0362 FMI 06 diagnostic code remains active. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE CLUTCH FOR A SHORT TO GROUND.
Turn the key start switch and the disconnect switch to the OFF position.
The clutch remains disconnected from the machine harness.
Disconnect the machine harness connector(s) from the ECM.
At the machine harness connector, measure the resistance from the signal contact J2-24 (wire G834-PU(Purple)) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-24 (wire G834-PU(Purple)) and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness. STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 0362 FMI 06 diagnostic code. Expected Result:The CID 0362 FMI 06 diagnostic code is active. Results:
YES - The CID 0362 FMI 06 diagnostic code is active. The diagnostic code has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the Machine ECM. See Testing and
Caterpillar parts catalog:
Parts seal Caterpillar catalog:
7X4756
SEAL
854G, 854K, 992K, 993K, D11N, D11R, D11T
854G, 854K, 992K, 993K, D11N, D11R, D11T
8C4895
SEAL-HEAD
D11N, D11R, D11T, R1700 II, R1700G
D11N, D11R, D11T, R1700 II, R1700G
3E6758
SEAL-LIP TYPE
AP-1055B, AP-655C, AP-655D, AP1055E, BG-2455D, BG1055E, BG655D, D10N, D10R, D10T, D10T2, D11R, D11T
AP-1055B, AP-655C, AP-655D, AP1055E, BG-2455D, BG1055E, BG655D, D10N, D10R, D10T, D10T2, D11R, D11T
9X7391
SEAL-O-RING
CB-44B, D11R, D11T
CB-44B, D11R, D11T
2227007
SEAL AS
5130, 5130B, D11N, D11R, D11T
5130, 5130B, D11N, D11R, D11T
1627864
SEAL GP-DUO-CONE
D10N, D10R, D10T, D10T2, D11R, D11T
D10N, D10R, D10T, D10T2, D11R, D11T
1725093
SEAL GP-DUO-CONE
D11R, D11T
D11R, D11T
8P8796
SEAL AS
D10, D11N, D11R, D11T
D10, D11N, D11R, D11T
8P8797
SEAL AS
D10, D11N, D11R, D11T
D10, D11N, D11R, D11T
9X4590
SEAL AS
D11N, D11R, D11T
D11N, D11R, D11T
8T1115
SEAL-PIVOT SHAFT
D10, D11N, D11R, D11T
D10, D11N, D11R, D11T
8T2863
SEAL-U-CUP
D11N, D11R, D11T
D11N, D11R, D11T
2226998
SEAL AS
D7R, D8N, D8R, D8R II, D8T
D7R, D8N, D8R, D8R II, D8T
1663322
SEAL
D8R
D8R
1597307
SEAL AS
D8R
D8R
1597309
SEAL AS
D8R
D8R
8T3279
SEAL-QUAD RING
D10, D11N, D11R, D11T
D10, D11N, D11R, D11T
1242375
SEAL-LIP TYPE
D10R, D10T, D10T2, D11N, D11R
D10R, D10T, D10T2, D11N, D11R
9X7696
SEAL-LIP TYPE
D11N, D11R
D11N, D11R
1330441
SEAL GP-DUO-CONE
D11N, D11R
D11N, D11R