1721619 SEAL GP-HEAVY DUTY DUAL FACE Caterpillar parts
Rating:
Alternative (cross code) number:
CA1721619
172-1619
1721619
CA1721619
172-1619
1721619
Weight: 1 pounds 0 kg.
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
No Parking At Any Time White Red Black Folding Coroplast A-Frame with Double-Sided 23in x23in
Work House Signs Durable Folding A-Frame Sign – Made from industrial-grade coroplast (corrugated plastic) that is lightweight, waterproof, and UV-resistant, built to handle indoor or outdoor use. || Double-Sided Display – Features two 23"x23" sign panels for maximum visibility from both directions, making it ideal for sidewalk advertising, storefront signage, open house signs, and event promotions. || Lightweight & Portable – Easy to carry, set up, and fold flat for compact storage or transport; perfect for temporary business signs, trade shows, and real estate marketing. || Versatile Business Signage – Use as a sidewalk sign, retail display board, restaurant menu stand, or event directional sign—a cost-effective solution for high-impact advertising. || Professional Presentation – Clean, modern design delivers a polished look that draws attention to your message, ideal for small businesses, restaurants, boutiques, and service providers.
Work House Signs Durable Folding A-Frame Sign – Made from industrial-grade coroplast (corrugated plastic) that is lightweight, waterproof, and UV-resistant, built to handle indoor or outdoor use. || Double-Sided Display – Features two 23"x23" sign panels for maximum visibility from both directions, making it ideal for sidewalk advertising, storefront signage, open house signs, and event promotions. || Lightweight & Portable – Easy to carry, set up, and fold flat for compact storage or transport; perfect for temporary business signs, trade shows, and real estate marketing. || Versatile Business Signage – Use as a sidewalk sign, retail display board, restaurant menu stand, or event directional sign—a cost-effective solution for high-impact advertising. || Professional Presentation – Clean, modern design delivers a polished look that draws attention to your message, ideal for small businesses, restaurants, boutiques, and service providers.
This part in 4 request:
Show.
This information for suppliers only!
2024-04-10
2024-03-07
2021-11-15
2021-06-23
Information:
the recent shortage and higher cost of new antifreeze and the disposal problems of used engine coolant, the interest in recycling the used engine coolant has sharply increased. Various methods have been proposed to reclaim used coolant for reuse in engine cooling systems. The coolant reclaiming methods include various filtering processes and full distillation of the water and ethylene glycol from the coolant. The ethylene glycol is that part of antifreeze which provides low temperature freeze protection. The commercial antifreezes contain ethylene glycol and various chemical inhibitors to prevent corrosion and damage to surfaces in cooling systems.
The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant. The ethylene glycol and water obtained from this process can be treated with new chemical corrosion inhibitors to provide a like-new coolant.
Throughout the normal life of a diesel engine coolant, supplemental corrosion inhibitors are added periodically. These chemicals are dissolved in the water part of the coolant mixture. During the normal life of the coolant mixture, the water will continue to hold these chemicals in solution until the saturation point is reached. At this point, the coolant should be replaced.
Based on Caterpillar's recommended rate of adding corrosion inhibitor, normal coolant life is 3000 hours or 2 years, whichever comes first. On-highway truck engine mileage for coolant change will vary depending on the average miles per hour accumulation.Filtering methods for reclaiming the used engine coolant do not reduce the level of chemicals in the water. The already chemically-saturated water is put back into the engine. As new corrosion inhibitor is added to this chemically-saturated water, it cannot go into solution with the water. The corrosion inhibitor will remain in the solid state. This causes detrimental effects because deposits form on heat transfer surfaces, clog flow passages, and get between water pump seal faces.
Therefore, the distillation method is the only effective method to reclaim used engine coolant. The "pure" ethylene glycol and "pure" water are boiled out of the used coolant and then condensed back to a liquid for reuse. All the chemical additives and corrosion/erosion products from the cooling system remain as a residue in the distillation process. This solid residue which is about 10% of the volume of the initial used coolant remains for disposal as waste.
Commercial units are available to do this distillation process. Contact Caterpillar Service Technology Group:
Outside Illinois: 1-800-542-TOOLInside Illinois: 1-800-541-TOOLCanada: 1-800-523-TOOL
The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant. The ethylene glycol and water obtained from this process can be treated with new chemical corrosion inhibitors to provide a like-new coolant.
Throughout the normal life of a diesel engine coolant, supplemental corrosion inhibitors are added periodically. These chemicals are dissolved in the water part of the coolant mixture. During the normal life of the coolant mixture, the water will continue to hold these chemicals in solution until the saturation point is reached. At this point, the coolant should be replaced.
Based on Caterpillar's recommended rate of adding corrosion inhibitor, normal coolant life is 3000 hours or 2 years, whichever comes first. On-highway truck engine mileage for coolant change will vary depending on the average miles per hour accumulation.Filtering methods for reclaiming the used engine coolant do not reduce the level of chemicals in the water. The already chemically-saturated water is put back into the engine. As new corrosion inhibitor is added to this chemically-saturated water, it cannot go into solution with the water. The corrosion inhibitor will remain in the solid state. This causes detrimental effects because deposits form on heat transfer surfaces, clog flow passages, and get between water pump seal faces.
Therefore, the distillation method is the only effective method to reclaim used engine coolant. The "pure" ethylene glycol and "pure" water are boiled out of the used coolant and then condensed back to a liquid for reuse. All the chemical additives and corrosion/erosion products from the cooling system remain as a residue in the distillation process. This solid residue which is about 10% of the volume of the initial used coolant remains for disposal as waste.
Commercial units are available to do this distillation process. Contact Caterpillar Service Technology Group:
Outside Illinois: 1-800-542-TOOLInside Illinois: 1-800-541-TOOLCanada: 1-800-523-TOOL
Caterpillar parts catalog:
Parts seal Caterpillar catalog:
1643951
SEAL-LIP TYPE
Caterpillar
Caterpillar
1309474
SEAL-O-RING
Caterpillar
Caterpillar
5P6301
SEAL (51 DM)--FRAME MOUNTED DOOR SEAL
Caterpillar
Caterpillar
5494307
SEAL-O-RING
Caterpillar
Caterpillar
2116977
SEAL RING-PISTON
Caterpillar
Caterpillar
2116973
SEAL RING-PISTON
Caterpillar
Caterpillar
1904949
SEAL
Caterpillar
Caterpillar
1889759
SEAL
Caterpillar
Caterpillar
1880632
SEAL-BRAKE
Caterpillar
Caterpillar
1841695
SEAL-RING
Caterpillar
Caterpillar