1864337 SEAL KIT- Caterpillar parts
Rating:
Alternative (cross code) number:
CA1864337
186-4337
1864337
CA1864337
186-4337
1864337
Weight: 0.34 pounds 0 kg.
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Replacement for fits 2422547 Kit-Seal-H Cylinder Fits Caterpillar 1864337
YFYANFEI
YFYANFEI
Replacement For 2422547 Kit-Seal-H Cylinder Fits Caterpillar 1864337
ZMYDZ Replacement For 2422547 Kit-Seal-H Cylinder Fits Caterpillar 1864337 || Brand New & High-Quality part || Most items are 1 packs, unless specifically stated that it is a 2 pack || Design improved for more durability, stable and updated characteristics, high reliability. || Kindly provide us with your Appliance Model Number and we will check if it's the right part you need. If not, we will sell you the correct one.
ZMYDZ Replacement For 2422547 Kit-Seal-H Cylinder Fits Caterpillar 1864337 || Brand New & High-Quality part || Most items are 1 packs, unless specifically stated that it is a 2 pack || Design improved for more durability, stable and updated characteristics, high reliability. || Kindly provide us with your Appliance Model Number and we will check if it's the right part you need. If not, we will sell you the correct one.
Information:
The ECM activates the start relay when the key start switch is in the START position and the direction switch is in the NEUTRAL position. The ECM detects a failure in the circuit for the start relay and the electrical system. If CID 0444 or CID 0168 are present the diagnostic code must be corrected before performing the following procedure "Check the key start switch". See Troubleshooting, "Diagnostic Code List".Test Step 1. CHECK THE KEY START SWITCH IN THE START POSITION.
Make sure that a CID 0444 diagnostic code does not exist. If the diagnostic code exists, correct the failure before proceeding.
Disconnect the ECM from the machine harness.
Turn the disconnect switch to the ON position.
Turn and hold the key start switch in the START position.
At the machine harness connector for the ECM, measure the voltage between contact J2-1 (wire 307-OR(Orange)) and contact J1-70 (ground). Expected Result:The +battery voltage should be present.Results:
YES - The +battery voltage is present. Proceed to Test Step 2.
NO - The +battery voltage is NOT present. The key start switch or the machine harness (wire 307-OR(Orange)) has failed. Check the key start switch and the machine harness.Repair: If necessary, replace the key start switch and/or the machine harness.STOPTest Step 2. CHECK THE KEY START SWITCH IN THE OFF POSITION.
The ECM remains disconnected from the machine harness.
Turn the key start switch to the OFF position.
At the machine harness connector for the ECM, measure the voltage between contact J2-1 (wire 307-OR(Orange)) and contact J1-70 (ground). Expected Result:The +battery voltage should be present.Results:
YES - The +battery voltage is present. The key start switch or the machine harness (wire 307-OR(Orange)) has failed. Check the key start switch and the machine harness.Repair: If necessary, replace the key start switch and/or the machine harness.STOP
NO - The +battery voltage is NOT present. The harness circuit operates correctly. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Perform these test steps again. If the cause is not found, replace the ECM. See Testing and Adjusting, "Electronic Control System (ECM) - Replace".STOP
Make sure that a CID 0444 diagnostic code does not exist. If the diagnostic code exists, correct the failure before proceeding.
Disconnect the ECM from the machine harness.
Turn the disconnect switch to the ON position.
Turn and hold the key start switch in the START position.
At the machine harness connector for the ECM, measure the voltage between contact J2-1 (wire 307-OR(Orange)) and contact J1-70 (ground). Expected Result:The +battery voltage should be present.Results:
YES - The +battery voltage is present. Proceed to Test Step 2.
NO - The +battery voltage is NOT present. The key start switch or the machine harness (wire 307-OR(Orange)) has failed. Check the key start switch and the machine harness.Repair: If necessary, replace the key start switch and/or the machine harness.STOPTest Step 2. CHECK THE KEY START SWITCH IN THE OFF POSITION.
The ECM remains disconnected from the machine harness.
Turn the key start switch to the OFF position.
At the machine harness connector for the ECM, measure the voltage between contact J2-1 (wire 307-OR(Orange)) and contact J1-70 (ground). Expected Result:The +battery voltage should be present.Results:
YES - The +battery voltage is present. The key start switch or the machine harness (wire 307-OR(Orange)) has failed. Check the key start switch and the machine harness.Repair: If necessary, replace the key start switch and/or the machine harness.STOP
NO - The +battery voltage is NOT present. The harness circuit operates correctly. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Perform these test steps again. If the cause is not found, replace the ECM. See Testing and Adjusting, "Electronic Control System (ECM) - Replace".STOP
Parts seal Caterpillar catalog:
1864336
SEAL KIT-
Caterpillar
Caterpillar
1864335
SEAL KIT-
Caterpillar
Caterpillar
1864333
SEAL KIT-
Caterpillar
Caterpillar
1864331
SEAL KIT-
Caterpillar
Caterpillar
1864330
SEAL KIT-
Caterpillar
Caterpillar
1864328
SEAL KIT-
Caterpillar
Caterpillar
1864343
SEAL KIT-
Caterpillar
Caterpillar
1864342
SEAL KIT-
Caterpillar
Caterpillar
1864341
SEAL KIT-
Caterpillar
Caterpillar
1864340
SEAL KIT-
Caterpillar
Caterpillar
1864339
SEAL KIT-
Caterpillar
Caterpillar
1864338
SEAL KIT-
Caterpillar
Caterpillar