2170332 SEAL Caterpillar parts
R1600, R1600G, R1700 II, R1700G, R2900, R2900G
Rating:
Alternative (cross code) number:
CA2170332
217-0332
2170332
CA2170332
217-0332
2170332
Weight: 0.01 pounds 0 kg.
LOAD HAUL DUMP,
Compatible equipment models: 2170332:
Information:
Illustration 1 g01129151
(8) Evaporator
(A) Refrigerant from the expansion valve
(B) Vaporized refrigerant to the compressor The expansion valve delivers a controlled amount of liquid refrigerant to evaporator (8). The liquid refrigerant has low temperature and low pressure. Since the pressure of the liquid refrigerant is low, the temperature of saturation of the refrigerant is low. At the temperature of saturation, the refrigerant changes from a liquid into a vapor. The temperature of saturation of a fluid increases when the pressure of a fluid increases.Fins on the evaporator coil are exposed to the air that is inside of the cab. The heat from the air that is inside of the cab is absorbed by the evaporator. The evaporator transfers the heat to the refrigerant. The amount of heat that is required to reach the temperature of saturation is called the latent heat of vaporization. When this heat is absorbed by the refrigerant, the temperature of the refrigerant will increase. When the temperature of the refrigerant reaches the temperature of saturation, the refrigerant will change from a liquid into a vapor. The vaporized refrigerant will leave the evaporator. The vaporized refrigerant will carry away the heat from the cab. The vaporized refrigerant will return to the compressor when the refrigerant leaves the evaporator. This process is repeated continuously.Moisture in the air condenses by cooling. This results in small amounts of water that attaches to the outside surface of the evaporator. When water freezes on the evaporator coil, the cooling system's performance will decrease. Adequate drainage for this water must be present in order to prevent freezing water on the evaporator coil.The amount of refrigerant that is supplied to the evaporator is adjusted by the expansion valve. In order to make precise adjustment, the evaporator requires less of a drop in refrigerant pressure. Therefore, decreasing the drop in pressure is one element that fully utilizes the ability of the evaporator.
Caterpillar parts catalog:
Parts seal Caterpillar catalog:
2170234
SEAL AS-LH
R1700G
R1700G
2565097
SEAL AS-BOTTOM
R1700G
R1700G
2170233
SEAL AS-RH
R1700G
R1700G
1666080
SEAL-O-RING
69D, AD30, AD45, AD55, AE40 II, R1300, R1600, R1600G, R1700 II, R1700G, R2900, R2900G
69D, AD30, AD45, AD55, AE40 II, R1300, R1600, R1600G, R1700 II, R1700G, R2900, R2900G
3D2864
SEAL
69D
69D
3020265
SEAL
R1700 II, R1700G
R1700 II, R1700G
3020252
SEAL
R1700 II, R1700G
R1700 II, R1700G
2345267
SEAL
R1600, R1600G, R1700 II, R1700G, R2900, R2900G
R1600, R1600G, R1700 II, R1700G, R2900, R2900G
2170333
SEAL
R1600, R1600G, R1700 II, R1700G, R2900, R2900G
R1600, R1600G, R1700 II, R1700G, R2900, R2900G
2170331
SEAL
R1600, R1600G, R1700 II, R1700G, R2900, R2900G
R1600, R1600G, R1700 II, R1700G, R2900, R2900G
2170334
SEAL
R1600, R1600G, R1700 II, R1700G
R1600, R1600G, R1700 II, R1700G