2173673 SEAL-ISOLATION Caterpillar parts
140H, 143H, 14H, 14M, 160H, 163H, 16H, 16M, 3196, 345C, 345C L, 345C MH, 345D, 345D L, 345D L VG, 349D, 349D L, 349E, 349E L, 349E L HVG, 349E L VG, 349F L, 621H, 621K, 623H, 623K, 623K LRC, 627H, 627...
Rating:
Alternative (cross code) number:
CA2173673
217-3673
2173673
CA2173673
217-3673
2173673
Weight: 1 pounds 0 kg.
ARTICULATED TRUCK, WHEELED EXCAVATOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
2173673 Seal-Isolation (New AFTERMARKET) - G&T Engine Parts
G&T Engine Parts Fits equipment: ARTICULATED DUMP TRUCK: 725, 730; ENGINE - MACHINE: 3176C, 3196, C12, C13, C11; EXCAVATOR: 345C. ARTICULATED DUMP TRUCK: 725; 730; ENGINE - MACHINE: 3176C; 3196; C-12; C-13; C11. || Condition: NEW AFTERMARKET || Weight: 2.09 lbs Dimensions: 13.21-15.42-55 in || Related Items: m2173673 || Use of any OEM manufacturer name is not intended to represent any relationship between the two companies, instead it indicates that we sell replacement parts that are compatible with OEM components.
G&T Engine Parts Fits equipment: ARTICULATED DUMP TRUCK: 725, 730; ENGINE - MACHINE: 3176C, 3196, C12, C13, C11; EXCAVATOR: 345C. ARTICULATED DUMP TRUCK: 725; 730; ENGINE - MACHINE: 3176C; 3196; C-12; C-13; C11. || Condition: NEW AFTERMARKET || Weight: 2.09 lbs Dimensions: 13.21-15.42-55 in || Related Items: m2173673 || Use of any OEM manufacturer name is not intended to represent any relationship between the two companies, instead it indicates that we sell replacement parts that are compatible with OEM components.
High Visibility Vest Required Beyond This Point Danger 1 Single Sided 18x24 in Yard Road Sign w/stand
Work House Signs Large 18"x24" Size for Maximum Visibility – Get your message seen from a distance with this generously sized yard sign, ideal for drive-by traffic and foot visibility. || UV-Resistant for Long-Term Use – Advanced UV protection prevents sun damage, ensuring bold colors and clear messaging even after months of outdoor exposure. || Easy to Install & Reuse – Quick setup with wire stakes included, plus durable construction allows for multiple uses across seasons and events. || Versatile for Home or Business – Great for political campaigns, garage sales, real estate, business promotions, yard décor, event announcements, or custom messages
Work House Signs Large 18"x24" Size for Maximum Visibility – Get your message seen from a distance with this generously sized yard sign, ideal for drive-by traffic and foot visibility. || UV-Resistant for Long-Term Use – Advanced UV protection prevents sun damage, ensuring bold colors and clear messaging even after months of outdoor exposure. || Easy to Install & Reuse – Quick setup with wire stakes included, plus durable construction allows for multiple uses across seasons and events. || Versatile for Home or Business – Great for political campaigns, garage sales, real estate, business promotions, yard décor, event announcements, or custom messages
This part in 5 request:
Show.
This information for suppliers only!
2025-07-11
2024-01-15
2023-06-12
2019-07-11
2017-03-07
Information:
Uninterruptible Power Supply: UPS 1000S (S/N: CZS1-UP) UPS 120 (S/N: CNK1-UP) UPS 1200S (S/N: CZT1-UP) UPS 150 (S/N: CPC1-UP) UPS 250 (S/N: BEE1-UP; CNM1-UP; APZ1-UP) UPS 300 (S/N: CNJ1-UP; CPZ1-UP) UPS 301 (S/N: CSY1-UP) UPS 500 (S/N: CSE1-UP) UPS 600 (S/N: CTX1-UP) UPS 750 (S/N: CPM1-UP) UPS 900 (S/N: CRY1-UP)Introduction
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is provided below.Problem
The vacuum pump has incurred an early hour failure due to one or more of the following results:
improper procedure for storage
improper setup procedure
improper troubleshooting procedureSolution
The following procedures will provide enhanced information regarding the vacuum pump:
procedure for storage
setup procedure
troubleshooting procedureProcedure for Storage
Normal Operating Range Minimum temperature ... 0 °C (32 °F) Maximum temperature ... 40 °C (104 °F)Range of Humidity Minimum Humidity "Non-condensing" ... 5% Maximum Humidity "Non-condensing" ... 95%The vacuum pump has the following specifications for short term storage:Short Term Temperature Range Minimum temperature ... −25 °C (−13 °F) Maximum temperature ... 70 °C (158 °F)Short Term Range of Humidity Minimum Humidity "Non-condensing" ... 65% Maximum Humidity "Non-condensing" ... 95%Short Term Storage - Short Term defines the storage period of two months or less.Short Term conditions cover the time when the equipment is in transit from the factory to the dealer or from the dealer to the customer site. The system should be stored under short term conditions for only two months or less.The vacuum pump has the following specifications for long term storage:Long Term Temperature Range Minimum temperature ... 0 °C (32 °F) Maximum temperature ... 40 °C (104 °F)Long Term Range of Humidity Minimum Humidity "Non-condensing" ... 5% Maximum Humidity "Non-condensing" ... 95%Long Term Storage - Long Term defines the storage period of three to twelve months.The system can be stored under long term conditions without any additional concerns. If the UPS is stored longer than one year, you will need to change the oil for the vacuum pump. Thereafter, change the oil in the vacuum pump annually. After completing the oil change for the vacuum pump, you will need to energize the vacuum pump. Operate the vacuum pump for four hours. Operation of the pump will ensure proper lubrication of the seals for the vacuum pump.The vacuum pump is shipped from Service Parts without oil. Therefore, you are not required to change the oil for the vacuum pump for any inventory from service parts.Do not utilize a vacuum pump that has exceeded specifications for storage of the vacuum pump. Do not utilize a vacuum pump that has exceeded the operational environmental specifications of the vacuum pump. The vacuum pump must be replaced. The replacement cost of the vacuum pump is not a warrantable repair. Setup Procedure
The vacuum pump has a tamperproof label. This prohibits the service technician from utilizing a 120 VAC source to begin the process for vacuum draw on the flywheel during the commissioning procedure. A tamperproof label that is corrupted will void any warranty claim that is associated
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is provided below.Problem
The vacuum pump has incurred an early hour failure due to one or more of the following results:
improper procedure for storage
improper setup procedure
improper troubleshooting procedureSolution
The following procedures will provide enhanced information regarding the vacuum pump:
procedure for storage
setup procedure
troubleshooting procedureProcedure for Storage
Normal Operating Range Minimum temperature ... 0 °C (32 °F) Maximum temperature ... 40 °C (104 °F)Range of Humidity Minimum Humidity "Non-condensing" ... 5% Maximum Humidity "Non-condensing" ... 95%The vacuum pump has the following specifications for short term storage:Short Term Temperature Range Minimum temperature ... −25 °C (−13 °F) Maximum temperature ... 70 °C (158 °F)Short Term Range of Humidity Minimum Humidity "Non-condensing" ... 65% Maximum Humidity "Non-condensing" ... 95%Short Term Storage - Short Term defines the storage period of two months or less.Short Term conditions cover the time when the equipment is in transit from the factory to the dealer or from the dealer to the customer site. The system should be stored under short term conditions for only two months or less.The vacuum pump has the following specifications for long term storage:Long Term Temperature Range Minimum temperature ... 0 °C (32 °F) Maximum temperature ... 40 °C (104 °F)Long Term Range of Humidity Minimum Humidity "Non-condensing" ... 5% Maximum Humidity "Non-condensing" ... 95%Long Term Storage - Long Term defines the storage period of three to twelve months.The system can be stored under long term conditions without any additional concerns. If the UPS is stored longer than one year, you will need to change the oil for the vacuum pump. Thereafter, change the oil in the vacuum pump annually. After completing the oil change for the vacuum pump, you will need to energize the vacuum pump. Operate the vacuum pump for four hours. Operation of the pump will ensure proper lubrication of the seals for the vacuum pump.The vacuum pump is shipped from Service Parts without oil. Therefore, you are not required to change the oil for the vacuum pump for any inventory from service parts.Do not utilize a vacuum pump that has exceeded specifications for storage of the vacuum pump. Do not utilize a vacuum pump that has exceeded the operational environmental specifications of the vacuum pump. The vacuum pump must be replaced. The replacement cost of the vacuum pump is not a warrantable repair. Setup Procedure
The vacuum pump has a tamperproof label. This prohibits the service technician from utilizing a 120 VAC source to begin the process for vacuum draw on the flywheel during the commissioning procedure. A tamperproof label that is corrupted will void any warranty claim that is associated
Cat SIS web machinery list:
Parts seal Caterpillar catalog:
2552272
SEAL GP-DUO-CONE
328D LCR, 330C L, 330D, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 336E, 336E H, 336E HVG, 336E L, 336E LH, 336E LN, 336F L, 340D L, 340D2 L, 345C MH, 345D L, 349D L, 349E, 349E ...
328D LCR, 330C L, 330D, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 336E, 336E H, 336E HVG, 336E L, 336E LH, 336E LN, 336F L, 340D L, 340D2 L, 345C MH, 345D L, 349D L, 349E, 349E ...
2059025
SEAL GP-DUO-CONE
330C, 330D L, 330D MH, 345B II, 345B II MH, 345B L, 345C, 345C L, 345C MH, 345D, 345D L, 345D L VG, 349D, 349D L
330C, 330D L, 330D MH, 345B II, 345B II MH, 345B L, 345C, 345C L, 345C MH, 345D, 345D L, 345D L VG, 349D, 349D L
1264002
SEAL-O-RING
330C, 330D L, 330D MH, 345B II, 345B II MH, 345C, 345C L, 345C MH, 345D, 345D L, 345D L VG, 349D, 349D L, 349E, 349E L, 349E L HVG, 349E L VG, 349F L, 374D L, 374F L
330C, 330D L, 330D MH, 345B II, 345B II MH, 345C, 345C L, 345C MH, 345D, 345D L, 345D L VG, 349D, 349D L, 349E, 349E L, 349E L HVG, 349E L VG, 349F L, 374D L, 374F L
2147880
SEAL GP-DUO-CONE
345B II, 345C, 345C L, 365B, 365B II, 365C, 365C L, 365C L MH, 374D L, 374F L
345B II, 345C, 345C L, 365B, 365B II, 365C, 365C L, 365C L MH, 374D L, 374F L
3678471
SEAL-O-RING
345C, 345C L, 345D, 345D L, 345D L VG, 349D, 349D L, 349E, 349E L, 349E L VG, 349F L, 365B II, 365C, 365C L, 374D L, 374F L, 385B, 385C, 385C L, 390D, 390D L, 390F L
345C, 345C L, 345D, 345D L, 345D L VG, 349D, 349D L, 349E, 349E L, 349E L VG, 349F L, 365B II, 365C, 365C L, 374D L, 374F L, 385B, 385C, 385C L, 390D, 390D L, 390F L
0931347
SEAL-O-RING
328D LCR, 345B II, 345B L, 345C, 345C L, 345D L, 349E L, 349E L VG, 349F L, 350, 365B, 365B II, 365B L, E650
328D LCR, 345B II, 345B L, 345C, 345C L, 345D L, 349E L, 349E L VG, 349F L, 350, 365B, 365B II, 365B L, E650
2590734
SEAL-U-CUP
325C, 330C L, 330D L, 336D, 336D2, 340D L, 340D2 L, 345B II, 345C, 345D, 345D L, 349D, 349D L
325C, 330C L, 330D L, 336D, 336D2, 340D L, 340D2 L, 345B II, 345C, 345D, 345D L, 349D, 349D L
2667957
SEAL-BUFFER
325C, 330C L, 330D L, 336D, 336D2, 340D L, 340D2 L, 345B II, 345C, 345D, 345D L, 349D, 349D L
325C, 330C L, 330D L, 336D, 336D2, 340D L, 340D2 L, 345B II, 345C, 345D, 345D L, 349D, 349D L
2667960
SEAL-O-RING
325C, 330C L, 330D L, 336D, 336D2, 340D L, 340D2 L, 345B II, 345C, 345D, 345D L, 349D, 349D L
325C, 330C L, 330D L, 336D, 336D2, 340D L, 340D2 L, 345B II, 345C, 345D, 345D L, 349D, 349D L
2590736
SEAL-U-CUP
345B II, 345C, 345D, 345D L, 349D, 349D L
345B II, 345C, 345D, 345D L, 349D, 349D L
2377623
SEAL-O-RING
3406E, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 374F L, 5130, 5130B, 5230, 5230B, 776C, 776D, 777D, 784C, 785B, 785C, 789, 789B, 789C, 789D, 793B, 793C, 793D, 797, 797B, 854G, 992G, 994, ...
3406E, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 374F L, 5130, 5130B, 5230, 5230B, 776C, 776D, 777D, 784C, 785B, 785C, 789, 789B, 789C, 789D, 793B, 793C, 793D, 797, 797B, 854G, 992G, 994, ...
1305694
SEAL-O-RING
3406C, 3406E, C-15, C15, C18, C32
3406C, 3406E, C-15, C15, C18, C32
1218117
SEAL-O-RING
3406E, C-15, C15, C18, M312, M313C, M313D, M315, M315C, M315D, M315D 2, M316C, M316D, M317D 2, M318, M318C, M318C MH, M318D, M318D MH, M320, M322C, M322D, M322D MH
3406E, C-15, C15, C18, M312, M313C, M313D, M315, M315C, M315D, M315D 2, M316C, M316D, M317D 2, M318, M318C, M318C MH, M318D, M318D MH, M320, M322C, M322D, M322D MH
3909009
SEAL-O-RING
3406E, C-15, C15, C18
3406E, C-15, C15, C18
4451693
SEAL AS-WATER PUMP
3406E, C-15, C15, C18
3406E, C-15, C15, C18
3521586
SEAL AS
3406E, C-15, C15, C18
3406E, C-15, C15, C18
1028817
SEAL
307B, 315B, 315B FM L, 3176B, 3176C, 3196, 320B, 320B FM LL, 321B, 322B, 325B, 325B L, 330B, 330B L, 3406E, 3412E, 3456, 345B, 345B L, 365B, 385B, 5090B, 834G, 836G, 918F, 924F, 938F, 950F, 950G, 962G...
307B, 315B, 315B FM L, 3176B, 3176C, 3196, 320B, 320B FM LL, 321B, 322B, 325B, 325B L, 330B, 330B L, 3406E, 3412E, 3456, 345B, 345B L, 365B, 385B, 5090B, 834G, 836G, 918F, 924F, 938F, 950F, 950G, 962G...
4237253
SEAL-RUBBER
3196, C-12, C12
3196, C-12, C12
3524333
SEAL-O-RING
3176C, 3196, 584, C-12, C12
3176C, 3196, 584, C-12, C12
8T4894
SEAL-O-RING
303.5, 315, 317, 3176C, 3196, 330B L, 345B, 345B II, 345B L, 5130, C-12, C12, E110B, E120B, M312, M313C
303.5, 315, 317, 3176C, 3196, 330B L, 345B, 345B II, 345B L, 5130, C-12, C12, E110B, E120B, M312, M313C
1310072
SEAL
3176C, 3196, C-12, C12
3176C, 3196, C-12, C12
1310071
SEAL AS
3176C, 3196, C-12, C12
3176C, 3196, C-12, C12