3004434 SEAL Caterpillar parts
735, 740
Rating:
Alternative (cross code) number:
CA3004434
300-4434
3004434
CA3004434
300-4434
3004434
Weight: 0.70 pounds 0 kg.
ARTICULATED TRUCK, EJECTOR TRUCK,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Information:
Starting the Fault Diagnosis
Illustration 1 g02338096
Control Panel (1a) Temperature select switch (increase) (1b) Temperature select switch (decrease) (2) Air inlet select switch (3) Main power On/Off switch (4) Display of set temperature (5) Defrost switch
Turn the engine start switch to ON.
Turn main power switch (3) of the air conditioner to OFF.
Depress temperature select switch (increase) (1a) and the temperature select switch (decrease) (1b) on the control panel at the same time. Hold both switches down for at least 3 seconds.
The diagnosis procedure shall start. If any error is memorized, the smallest error code is displayed on display (4) . If no problems exist, "E-.-" is displayed.
When the temperature select switch (increase) (1a) is depressed, error codes are displayed. The error codes are displayed in ascending order from "E11" to "E45". When the temperature select switch (decrease) (1b) is depressed, error codes are displayed. The error codes are displayed in descending order from "E45" to "E11".Note: When only one error code exists, the same display is repeated. A flashing display means that the error code is continuing from the past. A non-flashing display means that the error code was found in the past, but the error code is not found now.
When the fault diagnosis is running, the control of each function is altered.
All outputs from the control panel except error codes are turned OFF.
The panel light turns ON.
Clear the error codes. Depress air inlet select switch (2) and defrost switch (5 ) on the control panel at the same time. Hold both switches down for at least 3 seconds.Note: Clear any error codes when the equivalent problems have been repaired. Make sure that the same error code is not displayed again. When a problem has not yet been repaired, the equivalent error code should be displayed again.Ending the Fault Diagnosis
There are two ways to end the fault diagnosis.
Press main power switch (3) .
Turn the engine start switch to OFF.Error Codes
Table 1
Control Panel Diagnostic Error Codes    
Code    Problem Area    Problem    
"E11"     Intake air temperature sensor     Open circuit    
"E12"     Intake air temperature sensor     Short circuit    
"E13"     Ambient air temperature sensor     Open circuit    
"E14"     Ambient air temperature sensor     Short circuit    
"E15"     Water temperature sensor     Open circuit    
"E16"     Water temperature sensor     Short circuit    
"E21"     Evaporator sensor     Open circuit    
"E22"     Evaporator sensor     Short circuit    
"E33"     Air outlet motor     Open/Short circuit    
"E34"     Air blend motor     Open/Short circuit    
"E35"     Air inlet motor     Open/Short circuit    
"E43"     Damper for air outlet     No movement    
"E44"     Damper for air blend     No movement    
"E45"     Damper for air inlet     No movement    
"E51"     Refrigerant Pressure     High/Low error    Inspecting a Wiring Harness
Electrical problems are often caused by faulty electrical wires that have either an open circuit or a short circuit. The following procedures explain the test
Illustration 1 g02338096
Control Panel (1a) Temperature select switch (increase) (1b) Temperature select switch (decrease) (2) Air inlet select switch (3) Main power On/Off switch (4) Display of set temperature (5) Defrost switch
Turn the engine start switch to ON.
Turn main power switch (3) of the air conditioner to OFF.
Depress temperature select switch (increase) (1a) and the temperature select switch (decrease) (1b) on the control panel at the same time. Hold both switches down for at least 3 seconds.
The diagnosis procedure shall start. If any error is memorized, the smallest error code is displayed on display (4) . If no problems exist, "E-.-" is displayed.
When the temperature select switch (increase) (1a) is depressed, error codes are displayed. The error codes are displayed in ascending order from "E11" to "E45". When the temperature select switch (decrease) (1b) is depressed, error codes are displayed. The error codes are displayed in descending order from "E45" to "E11".Note: When only one error code exists, the same display is repeated. A flashing display means that the error code is continuing from the past. A non-flashing display means that the error code was found in the past, but the error code is not found now.
When the fault diagnosis is running, the control of each function is altered.
All outputs from the control panel except error codes are turned OFF.
The panel light turns ON.
Clear the error codes. Depress air inlet select switch (2) and defrost switch (5 ) on the control panel at the same time. Hold both switches down for at least 3 seconds.Note: Clear any error codes when the equivalent problems have been repaired. Make sure that the same error code is not displayed again. When a problem has not yet been repaired, the equivalent error code should be displayed again.Ending the Fault Diagnosis
There are two ways to end the fault diagnosis.
Press main power switch (3) .
Turn the engine start switch to OFF.Error Codes
Table 1
Control Panel Diagnostic Error Codes    
Code    Problem Area    Problem    
"E11"     Intake air temperature sensor     Open circuit    
"E12"     Intake air temperature sensor     Short circuit    
"E13"     Ambient air temperature sensor     Open circuit    
"E14"     Ambient air temperature sensor     Short circuit    
"E15"     Water temperature sensor     Open circuit    
"E16"     Water temperature sensor     Short circuit    
"E21"     Evaporator sensor     Open circuit    
"E22"     Evaporator sensor     Short circuit    
"E33"     Air outlet motor     Open/Short circuit    
"E34"     Air blend motor     Open/Short circuit    
"E35"     Air inlet motor     Open/Short circuit    
"E43"     Damper for air outlet     No movement    
"E44"     Damper for air blend     No movement    
"E45"     Damper for air inlet     No movement    
"E51"     Refrigerant Pressure     High/Low error    Inspecting a Wiring Harness
Electrical problems are often caused by faulty electrical wires that have either an open circuit or a short circuit. The following procedures explain the test
Caterpillar parts catalog:
Parts seal Caterpillar catalog:
9D6584
SEAL-LIP TYPE
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 14...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 14...
2239743
SEAL-LIP TYPE
24H, 24M, 735, 735B, 740, 740B, 773G, 773G OEM, 775G, 775G OEM, 776C, 776D, 777D, 777F, 777G, 784B, 784C, 785B, 785C, 785D, 789B, 789C, 793B, 854G, 854K, 992G, 992K, 993K
24H, 24M, 735, 735B, 740, 740B, 773G, 773G OEM, 775G, 775G OEM, 776C, 776D, 777D, 777F, 777G, 784B, 784C, 785B, 785C, 785D, 789B, 789C, 793B, 854G, 854K, 992G, 992K, 993K
1165897
SEAL-O-RING
365B, 375, 375 L, 5080, 735, 784B, 784C, 785B, 785C, 785D, 789B, 789C, 789D, 793, 793B, 793C, 793D, 793F, 793F CMD, 793F OEM, 793F-XQ
365B, 375, 375 L, 5080, 735, 784B, 784C, 785B, 785C, 785D, 789B, 789C, 789D, 793, 793B, 793C, 793D, 793F, 793F CMD, 793F OEM, 793F-XQ
1498434
SEAL GP-DUO-CONE
735, 740, AD30, D350E II, D400E II
735, 740, AD30, D350E II, D400E II
1378117
SEAL-RING
735, 735B, 740, 740B, 770, 770G, 770G OEM, 772, 772G, 772G OEM, D350E II, D400E II
735, 735B, 740, 740B, 770, 770G, 770G OEM, 772, 772G, 772G OEM, D350E II, D400E II
1378119
SEAL-RING
735, 735B, 740, 740B, 770, 770G, 770G OEM, 772, 772G, 772G OEM, AD30, D350E II, D400E II
735, 735B, 740, 740B, 770, 770G, 770G OEM, 772, 772G, 772G OEM, AD30, D350E II, D400E II
6W4310
SEAL-O-RING
735, 735B, 740, 740B, 770G, 770G OEM, 772, 772G, 772G OEM, D350E II, D400E II
735, 735B, 740, 740B, 770G, 770G OEM, 772, 772G, 772G OEM, D350E II, D400E II
2934503
SEAL-LIP TYPE
725, 725C, 730, 730C, 735, 735B, 740, 740B
725, 725C, 730, 730C, 735, 735B, 740, 740B
3634454
SEAL GP-HEAVY DUTY DUAL FACE
735, 735B, 740, 740B
735, 735B, 740, 740B
3634455
SEAL-O-RING
735, 735B, 740, 740B
735, 735B, 740, 740B
8D3971
SEAL-RING
16G, 16H, 16H NA, 735, 735B, 740, 740B
16G, 16H, 16H NA, 735, 735B, 740, 740B
3097664
SEAL GP-DUO-CONE
735, 735B, 740, 740B
735, 735B, 740, 740B
2117328
SEAL
735, 740
735, 740
2664043
SEAL-RUBBER
735, 740
735, 740
2179487
SEAL
735, 740
735, 740
2577094
SEAL
735, 740
735, 740
2U5388
SEAL-V-RING
735, 735B, 740, 740B, D25C, D30C, D350C, D35C, D35HP, D400
735, 735B, 740, 740B, D25C, D30C, D350C, D35C, D35HP, D400
1625517
SEAL
735, 735B, 740, 740B, AD30
735, 735B, 740, 740B, AD30
7Y4294
SEAL-O-RING
1090, 1190, 1190T, 1290T, 1390, 2290, 2390, 2391, 2484C, 2491, 2590, 322, 322 FM L, 322 LN, 322B L, 322B LN, 322C, 322C FM, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 324E, 324E L, 324E LN, 325, 325 ...
1090, 1190, 1190T, 1290T, 1390, 2290, 2390, 2391, 2484C, 2491, 2590, 322, 322 FM L, 322 LN, 322B L, 322B LN, 322C, 322C FM, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 324E, 324E L, 324E LN, 325, 325 ...
2528661
SEAL-RING
769D, 771D
769D, 771D
2U5382
SEAL-V-RING
740, 740B
740, 740B
3978039
SEAL
735, 735B, 740, 740B
735, 735B, 740, 740B
4B5432
SEAL-LIP TYPE
735, 735B, 740, 740B
735, 735B, 740, 740B
3432874
SEAL-BELLOWS
735, 740
735, 740