3285492 SEAL Caterpillar parts
120M, 120M 2, 12M, 12M 2, 140M, 140M 2, 14M, 160M, 160M 2, 16M, 773F, 775F, 777F, D7E, D7E LGP
Rating:
Alternative (cross code) number:
CA3285492
328-5492
3285492
CA3285492
328-5492
3285492
Weight: 0.04 pounds 0 kg.
MOTOR GRADER, TRUCK,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 3285492:
Information:
Conditions Which Generate This Code:
Illustration 1 g00519201
System Schematic For Unexpected ShutdownThe purpose of the CID 0566 is to alert the operator that the GSC+ did not control the engine shutdown. The GSC+ normally controls all engine shutdown functions, for both normal operation and fault shutdowns. If an outside influence causes an engine shutdown, the GSC+ declares a CID 0566. There is only one failure mode for a CID 0566 and it is FMI 07. FMI 07 is an improper mechanical response.This diagnostic code causes the following sequence of events:
On a running engine, the GSC+ detects that engine speed has dropped from rated to 0 rpm when the GSC+ has not called for a shutdown.
The GSC+ determines that no engine speed sensor fault is present that explains the drop in speed signal.
The GSC+ declares a CID 0566 FMI 07 and disables the engine from running or starting.Note: An unexpected shutdown fault (CID 0566) will initiate a circuit breaker shunt trip signal.Note: Diagnostic codes are created when the harness connector (40 contact) is disconnected from the GSC+ during these troubleshooting procedures. Clear these created diagnostic codes after the particular diagnostic codes is corrected and cleared. The possible cause of a CID 0566 FMI 07 is a component that is not under the control of the GSC+ has caused an engine shutdown.The GSC+ treats a CID 0566 FMI 07 as a shutdown fault. Clear the diagnostic code from the fault log after troubleshooting is complete.Note: This procedure requires many voltage measurements during simulated engine cranking. Starting motor fuse F4 on the relay module is removed to prevent activating the starting motor and actual engine cranking does not occur. Voltage measurements must be made quickly before the total cycle crank time (setpoint P017) elapses. The total cycle crank time is usually 90 seconds. See Systems Operation, "Engine/Generator Programming OP5-0". If a voltage measurement takes more than 90 seconds the GSC+ declares an overcrank fault and the overcrank shutdown indicator will FLASH. In order to continue with a voltage measurement, the overcrank fault must be reset by turning the ECS to OFF/RESET and then turn the ECS to START.Test Step 1. PERFORM AN INITIAL CHECK.
Make sure that there are NO OTHER ACTIVE DIAGNOSTIC CODES. This means that there are no diagnostic codes which are showing on the upper display. This means that no shutdown or alarm indicators are flashing. Failure to make sure that there are NO OTHER ACTIVE DIAGNOSTIC CODES may result in erroneous troubleshooting and needless replacement of parts. The operator will make many voltage measurements while the GSC+ is attempting to crank the engine. If the GSC+ detects other faults, the GSC+ will prevent starting by shutting off the fuel and air to the engine. The resulting voltage measurements would then be the exact opposite of the voltage which is expected in the procedures.
Check the fuel level and quality.
Check for a plugged fuel filter.
Check for a plugged air filter.
Refer to the Service Manual for the engine if there is an obvious
Illustration 1 g00519201
System Schematic For Unexpected ShutdownThe purpose of the CID 0566 is to alert the operator that the GSC+ did not control the engine shutdown. The GSC+ normally controls all engine shutdown functions, for both normal operation and fault shutdowns. If an outside influence causes an engine shutdown, the GSC+ declares a CID 0566. There is only one failure mode for a CID 0566 and it is FMI 07. FMI 07 is an improper mechanical response.This diagnostic code causes the following sequence of events:
On a running engine, the GSC+ detects that engine speed has dropped from rated to 0 rpm when the GSC+ has not called for a shutdown.
The GSC+ determines that no engine speed sensor fault is present that explains the drop in speed signal.
The GSC+ declares a CID 0566 FMI 07 and disables the engine from running or starting.Note: An unexpected shutdown fault (CID 0566) will initiate a circuit breaker shunt trip signal.Note: Diagnostic codes are created when the harness connector (40 contact) is disconnected from the GSC+ during these troubleshooting procedures. Clear these created diagnostic codes after the particular diagnostic codes is corrected and cleared. The possible cause of a CID 0566 FMI 07 is a component that is not under the control of the GSC+ has caused an engine shutdown.The GSC+ treats a CID 0566 FMI 07 as a shutdown fault. Clear the diagnostic code from the fault log after troubleshooting is complete.Note: This procedure requires many voltage measurements during simulated engine cranking. Starting motor fuse F4 on the relay module is removed to prevent activating the starting motor and actual engine cranking does not occur. Voltage measurements must be made quickly before the total cycle crank time (setpoint P017) elapses. The total cycle crank time is usually 90 seconds. See Systems Operation, "Engine/Generator Programming OP5-0". If a voltage measurement takes more than 90 seconds the GSC+ declares an overcrank fault and the overcrank shutdown indicator will FLASH. In order to continue with a voltage measurement, the overcrank fault must be reset by turning the ECS to OFF/RESET and then turn the ECS to START.Test Step 1. PERFORM AN INITIAL CHECK.
Make sure that there are NO OTHER ACTIVE DIAGNOSTIC CODES. This means that there are no diagnostic codes which are showing on the upper display. This means that no shutdown or alarm indicators are flashing. Failure to make sure that there are NO OTHER ACTIVE DIAGNOSTIC CODES may result in erroneous troubleshooting and needless replacement of parts. The operator will make many voltage measurements while the GSC+ is attempting to crank the engine. If the GSC+ detects other faults, the GSC+ will prevent starting by shutting off the fuel and air to the engine. The resulting voltage measurements would then be the exact opposite of the voltage which is expected in the procedures.
Check the fuel level and quality.
Check for a plugged fuel filter.
Check for a plugged air filter.
Refer to the Service Manual for the engine if there is an obvious
Cat SIS web machinery list:
Parts seal Caterpillar catalog:
9D6589
SEAL-LIP TYPE
12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 14G, 14H, 14H NA, 14M, 160H, 160H ES, 160H NA, 160K, 160M, 160M 2,...
12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 14G, 14H, 14H NA, 14M, 160H, 160H ES, 160H NA, 160K, 160M, 160M 2,...
9D6586
SEAL-LIP TYPE
140G, 14G, 14H, 14H NA, 16G, 16H, 16H NA, 16M
140G, 14G, 14H, 14H NA, 16G, 16H, 16H NA, 16M
8D4217
SEAL
14G, 14H, 14H NA, 14M
14G, 14H, 14H NA, 14M
8D3308
SEAL
14G, 14H, 14H NA, 14M, 16G, 16H, 16H NA, 16M
14G, 14H, 14H NA, 14M, 16G, 16H, 16H NA, 16M
5P8847
SEAL-LIP TYPE
14M, 16G, 16H, 16H NA, 16M
14M, 16G, 16H, 16H NA, 16M
9D6588
SEAL-LIP TYPE
16G, 16H, 16H NA, 16M
16G, 16H, 16H NA, 16M
8D3307
SEAL
16G, 16H, 16H NA, 16M
16G, 16H, 16H NA, 16M
3290411
SEAL-LIP TYPE
120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 160H, 160K, 160M, 160M 2, 163H
120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 160H, 160K, 160M, 160M 2, 163H
2035957
SEAL
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14M, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 16M
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14M, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 16M
1731007
SEAL
120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H,...
120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H,...
1757894
SEAL-O-RING
777F
777F
9J5570
SEAL
777D, 777F
777D, 777F
2892933
SEAL-WIPER
777D, 777F
777D, 777F
2892932
SEAL-WIPER
777D, 777F
777D, 777F
2746320
SEAL-O-RING
777F, 777G
777F, 777G
2700603
SEAL-O-RING
777F
777F
2964023
SEAL
777D, 777G
777D, 777G
8C5244
SEAL-QUAD RING
517, 518, 527, 773D, 777D, D4HTSK II, D4HTSK III, D5HTSK II
517, 518, 527, 773D, 777D, D4HTSK II, D4HTSK III, D5HTSK II
3087249
SEAL AS
773F, 775F
773F, 775F
2892974
SEAL-U-CUP
773F, 775F
773F, 775F
2892951
SEAL-LIP TYPE
773F, 775F
773F, 775F
2892934
SEAL-RING
773E, 773F, 775F
773E, 773F, 775F