Information:
Installation Procedure
Identify a location for installation of the bottle. Ensure that the location for installation is protected. Ensure that the location of the bottle is lower than the nozzle.Follow the steps that are listed below in order to install the bottle.
Locate the nozzle in a horizontal position less than 3.0m (10 ft) away from the bottle.
Locate the bottle no lower than 1.5 m (5 ft) from the nozzle.
Inspect the location for the installation and ensure that welding in the location will not damage any of the nearby components.
Illustration 3 g01341843
Typical Location of Installation for the Bottle
Weld the bosses onto the frame in order to mount the bottle.
Install the bottle for the cleaning system.
Mount the nozzle.The following requirements need to be followed for the installation of the nozzle.
Illustration 4 g01341929
For optimal performance install the nozzle within 25 mm (1 inch) of the camera lens.Note: When installing the nozzle ensure that the nozzle is not viewable in the camera image.
The nozzle needs to be angled at 45 degrees from the surface of the lens.
Illustration 5 g01338194
Nozzle
Mount the spray nozzle so that the projection of the spray cuts at the base of the glass.
Install the wiring harness. Route the wiring harness with the existing wiring harnesses.
Illustration 6 g01341873
Typical Installation of the Wiring Harness
Install the power wire to the pump. Install the ground wire to the pump. Refer to Illustration 9 for a system schematic.
Locate an suitable ground and Install the other end of the ground wire to the frame.
Locate a location for installation in the cab of the machine for the washer switch.
Illustration 7 g01341911
Typical Installation of the Washer Switch
Connect the cleaning system to an appropriately fused 24 volt power source.
Illustration 8 g01338195
Check Valve
Route the fluid line from the pump to the nozzle. Cut the fluid line and install the check valve no more than 304 mm (1 ft) away from the tank. Ensure that the arrow on the check valve is pointed away from the pump.Note: You must prime the pump before installing the check valve. In order to prime the pump allow the water to flow out of the line in order to purge the air out of the line.
Check the operation of the system.Wiring Schematic
Illustration 9 g01341969
System Connections
Identify a location for installation of the bottle. Ensure that the location for installation is protected. Ensure that the location of the bottle is lower than the nozzle.Follow the steps that are listed below in order to install the bottle.
Locate the nozzle in a horizontal position less than 3.0m (10 ft) away from the bottle.
Locate the bottle no lower than 1.5 m (5 ft) from the nozzle.
Inspect the location for the installation and ensure that welding in the location will not damage any of the nearby components.
Illustration 3 g01341843
Typical Location of Installation for the Bottle
Weld the bosses onto the frame in order to mount the bottle.
Install the bottle for the cleaning system.
Mount the nozzle.The following requirements need to be followed for the installation of the nozzle.
Illustration 4 g01341929
For optimal performance install the nozzle within 25 mm (1 inch) of the camera lens.Note: When installing the nozzle ensure that the nozzle is not viewable in the camera image.
The nozzle needs to be angled at 45 degrees from the surface of the lens.
Illustration 5 g01338194
Nozzle
Mount the spray nozzle so that the projection of the spray cuts at the base of the glass.
Install the wiring harness. Route the wiring harness with the existing wiring harnesses.
Illustration 6 g01341873
Typical Installation of the Wiring Harness
Install the power wire to the pump. Install the ground wire to the pump. Refer to Illustration 9 for a system schematic.
Locate an suitable ground and Install the other end of the ground wire to the frame.
Locate a location for installation in the cab of the machine for the washer switch.
Illustration 7 g01341911
Typical Installation of the Washer Switch
Connect the cleaning system to an appropriately fused 24 volt power source.
Illustration 8 g01338195
Check Valve
Route the fluid line from the pump to the nozzle. Cut the fluid line and install the check valve no more than 304 mm (1 ft) away from the tank. Ensure that the arrow on the check valve is pointed away from the pump.Note: You must prime the pump before installing the check valve. In order to prime the pump allow the water to flow out of the line in order to purge the air out of the line.
Check the operation of the system.Wiring Schematic
Illustration 9 g01341969
System Connections
Cat SIS web machinery list:
Parts seal Caterpillar catalog:
4958197
SEAL AS
Caterpillar
Caterpillar
4958179
SEAL AS
Caterpillar
Caterpillar
4903932
SEAL-LIP
Caterpillar
Caterpillar
4903930
SEAL-DUST
Caterpillar
Caterpillar
4896608
SEAL
Caterpillar
Caterpillar
4886565
SEAL GP-CAB
Caterpillar
Caterpillar
5019547
SEAL-O-RING
Caterpillar
Caterpillar
5000791
SEAL
Caterpillar
Caterpillar
4992421
SEAL
Caterpillar
Caterpillar
4990001
SEAL
Caterpillar
Caterpillar
4981492
SEAL-LIP
Caterpillar
Caterpillar
4960541
SEAL-RING
Caterpillar
Caterpillar