5433698 SEAL-LIP TYPE Caterpillar parts
Rating:
Alternative (cross code) number:
CA5433698
543-3698
5433698
CA5433698
543-3698
5433698
Weight: 0.07 pounds 0 kg.
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
5433697 4649758 5433698 GASKET and oil Compatible With CAT320 GC (Black-Rubber-4649758 GASKET)
Generic
Generic
D&D PowerDrive 5433698 Frigidaire Replacement Belt, A/4L, 1 -Band, 27" Length, Rubber
D&D PowerDrive Belt A/4L 1/2 x 27in OC || Product type - belts || Made in china || Package weight: 1.0 lbs
D&D PowerDrive Belt A/4L 1/2 x 27in OC || Product type - belts || Made in china || Package weight: 1.0 lbs
Information:
Illustration 1 g00721817
System Schematic For kW Level OutputThe kW level output will be activated whenever the total power output of the generator exceed the setpoint P139. The kW level output is the connector contact 34 of the GSC+. This setpoint can be programmed from 0 to 110 percent of the rated power on the nameplate (setpoint P030). This setpoint can be programmed with a time delay from 0 to 120 seconds (setpoint P140). See System Operation, "Engine/Generator Programming OP5-0". Also, see System Operation, "Service Mode". Once the output is activated, the kW level output will be deactivated when the total power output of the generator drops below a programmed setpoint (setpoint P141). This setpoint is different from the activation setpoint. This setpoint can be programmed from 0 to 110 percent of the power rating on the nameplate of the generator. This setpoint can be programmed with a time delay from 0 to 120 seconds.When kW relay is disconnected from the GSC+, the voltage on the kW level output is approximately 5.0 DCV. When kW relay is connected to the GSC+, the voltage on the kW level output is approximately 0 volts. The kW level output is capable of drawing (sinking) approximately 100 mA. Documenting and troubleshooting any connections to this output is the responsibility of the customers and the dealers. The possible cause of a CID 0859 FMI 03 is a short to the +battery circuit of the kW level output.The GSC+ treats a CID 0859 FMI 03 as an alarm fault.Troubleshooting of this failure is straight forward. The FMI 03 defines the problem as a short to "B+". Use the following information in order to find the exact cause of the diagnostic code.
FMI information
system schematic of the kW level output
customer's documentation
dealer's documentationTest Step 1. CHECK THE GENERATOR SET CONTROL
Verify that the CID 0859 FMI 03 diagnostic code is active.
Disconnect the wire from contact 34 of the GSC+.
Measure the voltage between contact 34 of the GSC+ and"B-".Expected Result:The voltage is approximately 5 1.0 DCV.Results:
OK - The voltage is approximately 5 1.0 DCV. The voltage is correct. Proceed to test step 2.
NOT OK - The voltage is NOT approximately 5 1.0 DCV. The voltage is NOT correct. The GSC+ has failed.Repair: It
Caterpillar parts catalog:
Parts seal Caterpillar catalog:
5391753
SEAL-O-RING
Caterpillar
Caterpillar
5391752
SEAL AS-PISTON
Caterpillar
Caterpillar
5388615
SEAL-O-RING
Caterpillar
Caterpillar
5356558
SEAL
Caterpillar
Caterpillar
5356556
SEAL-LIP
Caterpillar
Caterpillar
5356552
SEAL
Caterpillar
Caterpillar
5457472
SEAL AS
Caterpillar
Caterpillar
5455755
SEAL-BULK
Caterpillar
Caterpillar
5435057
SEAL-O-RING
Caterpillar
Caterpillar
5435005
SEAL-O-RING
Caterpillar
Caterpillar
5435003
SEAL
Caterpillar
Caterpillar
5433723
SEAL AS
Caterpillar
Caterpillar