Removal Procedure
Keep all parts clean from contaminants.Contaminants may cause rapid wear and shortened component life.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Dispose of all fluids according to local regulations and mandates.
Drain the coolant from the cooling system to a level below the water temperature regulator, into a suitable container for storage or for disposal. Refer to Operation and Maintenance Manual, "Cooling System Coolant - Change" for the correct draining procedure.
Illustration 1 g01985853
Typical example
Loosen the hose clamps from the upper radiator hose and disconnect the upper radiator hose from water temperature regulator housing (2).
Remove bolts (1) from water temperature regulator housing (2).
Remove water temperature regulator housing (2) from the cylinder head. Note: Note the orientation of the water temperature regulator housing.Installation Procedure
Keep all parts clean from contaminants.Contaminants may cause rapid wear and shortened component life.
Illustration 2 g01985853
Typical example
Ensure that all components of water temperature regulator housing (2) are clean and free of wear and damage. If any components of the water temperature regulator housing are worn or damaged, the complete assembly must be replaced.
Check the water temperature regulator for correct operation. Refer to System Operation, Testing, and Adjusting, "Water Temperature Regulator - Test" for the procedure to test the water temperature regulator. If the water temperature regulator is no operating correctly, the complete assembly must be replaced.
Install water temperature regulator housing (2) to the cylinder head. Note: Ensure the correct orientation of the water temperature regulator housing.
Install bolts (1). Tighten the bolts to a torque of 22 N m (195 lb in).
Connect the upper radiator hose and tighten the hose clamps securely.
Fill the cooling system to the correct level. Refer to Operation and Maintenance Manual, "Cooling System Coolant - Check" and Operation and Maintenance Manual, "Cooling System Coolant - Change" for the correct filling procedure.
Keep all parts clean from contaminants.Contaminants may cause rapid wear and shortened component life.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Dispose of all fluids according to local regulations and mandates.
Drain the coolant from the cooling system to a level below the water temperature regulator, into a suitable container for storage or for disposal. Refer to Operation and Maintenance Manual, "Cooling System Coolant - Change" for the correct draining procedure.
Illustration 1 g01985853
Typical example
Loosen the hose clamps from the upper radiator hose and disconnect the upper radiator hose from water temperature regulator housing (2).
Remove bolts (1) from water temperature regulator housing (2).
Remove water temperature regulator housing (2) from the cylinder head. Note: Note the orientation of the water temperature regulator housing.Installation Procedure
Keep all parts clean from contaminants.Contaminants may cause rapid wear and shortened component life.
Illustration 2 g01985853
Typical example
Ensure that all components of water temperature regulator housing (2) are clean and free of wear and damage. If any components of the water temperature regulator housing are worn or damaged, the complete assembly must be replaced.
Check the water temperature regulator for correct operation. Refer to System Operation, Testing, and Adjusting, "Water Temperature Regulator - Test" for the procedure to test the water temperature regulator. If the water temperature regulator is no operating correctly, the complete assembly must be replaced.
Install water temperature regulator housing (2) to the cylinder head. Note: Ensure the correct orientation of the water temperature regulator housing.
Install bolts (1). Tighten the bolts to a torque of 22 N m (195 lb in).
Connect the upper radiator hose and tighten the hose clamps securely.
Fill the cooling system to the correct level. Refer to Operation and Maintenance Manual, "Cooling System Coolant - Check" and Operation and Maintenance Manual, "Cooling System Coolant - Change" for the correct filling procedure.
Caterpillar parts catalog:
Parts seal Caterpillar catalog:
5515936
SEAL
Caterpillar
Caterpillar
5511109
SEAL-LIP TYPE
Caterpillar
Caterpillar
5505420
SEAL AS
Caterpillar
Caterpillar
5494308
SEAL-O-RING
Caterpillar
Caterpillar
5474350
SEAL
Caterpillar
Caterpillar
5457129
SEAL
Caterpillar
Caterpillar
6T8436
SEAL GP-DUO-CONE
Caterpillar
Caterpillar
57-40232
SEAL, RUBBER
Caterpillar
Caterpillar
5593652
SEAL-SQUARE
Caterpillar
Caterpillar
5537300
SEAL-O-RING
Caterpillar
Caterpillar
5536507
SEAL AS
Caterpillar
Caterpillar
5536506
SEAL AS
Caterpillar
Caterpillar