6V5340 SEAL-LIP TYPE Caterpillar parts
Rating:
Alternative (cross code) number:
CA6V5340
6V-5340
6V5340
CA6V5340
6V-5340
6V5340
Weight: 0.44 pounds 0 kg.
Information:
AXIAL WIDTH
11.5
mm
BORE DIAMETER
0
mm
CONSTRUCTION TYPE
SBI
MATERIAL
FKM Rubber - 80 Duro
SEAL OD
127.1
mm
SHAFT OD
104.78
mm
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Information:
Initial Start-Up
1. Remove the left side access panel of the generator.2. Loosen the locknuts on the voltage droop, voltage level, and voltage gain controls.3. Turn the voltage droop control (1) counterclockwise to zero droop and tighten the locknut.
VOLTAGE ADJUSTMENT CONTROLS (SR4 Generator Shown)
1. Voltage Droop 2. Voltage Level 3. Voltage Gain 4. Circuit Breaker (SR4 Generator Only)4. Turn the gain control (3) counterclockwise to zero, then turn the gain control to about 1/4 of full range of clockwise travel.5. Perform required maintenance on engine before starting.6. Start the engine and allow it to warm.7. Increase engine speed to full governed speed (high idle).8. Observe the voltmeter reading. If desired voltage is not indicated, set no load voltage with voltage level control (2).9. Close the load circuit breaker and apply full load gradually. Adjust governor control until nameplate frequency is on the Hertz meter.10. a. If voltmeter reading increases with full load applied, turn gain control (3) slightly in counterclockwise direction.b. If voltmeter reading decreases with full load applied, turn gain control (3) slightly in clockwise direction.11. Remove load, adjust voltage level control (2) if necessary to obtain desired voltage.12. Apply the load, observe voltmeter reading. Repeat steps 9 thru 12 until no load voltage equals full load voltage.13. Tighten the locknuts on all controls and install the access panel of the generator.14. Circuit breaker (4) will open if excessive field current should occur. Push to reset the circuit breaker. If breaker opens again, contact your Caterpillar dealer.Starting
1. Make all preliminary engine starting checks.2. Be sure the main or line circuit breaker is open.3. Start the engine and allow it to warm up.4. Adjust to full load RPM.5. Close the main circuit breaker.6. Apply the load. Do not try to apply full load in one move, rather apply the load in increments to maintain system frequency at a constant level.7. Readjust governor for rated frequency.Stopping
1. Remove the load in increments.2. Open the circuit breaker.3. Allow the engine to run for 5 minutes to cool.4. Stop the engine.
1. Remove the left side access panel of the generator.2. Loosen the locknuts on the voltage droop, voltage level, and voltage gain controls.3. Turn the voltage droop control (1) counterclockwise to zero droop and tighten the locknut.
VOLTAGE ADJUSTMENT CONTROLS (SR4 Generator Shown)
1. Voltage Droop 2. Voltage Level 3. Voltage Gain 4. Circuit Breaker (SR4 Generator Only)4. Turn the gain control (3) counterclockwise to zero, then turn the gain control to about 1/4 of full range of clockwise travel.5. Perform required maintenance on engine before starting.6. Start the engine and allow it to warm.7. Increase engine speed to full governed speed (high idle).8. Observe the voltmeter reading. If desired voltage is not indicated, set no load voltage with voltage level control (2).9. Close the load circuit breaker and apply full load gradually. Adjust governor control until nameplate frequency is on the Hertz meter.10. a. If voltmeter reading increases with full load applied, turn gain control (3) slightly in counterclockwise direction.b. If voltmeter reading decreases with full load applied, turn gain control (3) slightly in clockwise direction.11. Remove load, adjust voltage level control (2) if necessary to obtain desired voltage.12. Apply the load, observe voltmeter reading. Repeat steps 9 thru 12 until no load voltage equals full load voltage.13. Tighten the locknuts on all controls and install the access panel of the generator.14. Circuit breaker (4) will open if excessive field current should occur. Push to reset the circuit breaker. If breaker opens again, contact your Caterpillar dealer.Starting
1. Make all preliminary engine starting checks.2. Be sure the main or line circuit breaker is open.3. Start the engine and allow it to warm up.4. Adjust to full load RPM.5. Close the main circuit breaker.6. Apply the load. Do not try to apply full load in one move, rather apply the load in increments to maintain system frequency at a constant level.7. Readjust governor for rated frequency.Stopping
1. Remove the load in increments.2. Open the circuit breaker.3. Allow the engine to run for 5 minutes to cool.4. Stop the engine.
Parts seal Caterpillar catalog:
6V5098
SEAL-O-RING
Caterpillar
Caterpillar
6V5038
SEAL
Caterpillar
Caterpillar
6V4640
SEAL
Caterpillar
Caterpillar
6V4610
SEAL
Caterpillar
Caterpillar
6V3904
SEAL
Caterpillar
Caterpillar
6V3828
SEAL
Caterpillar
Caterpillar
6V5812
SEAL-LIP TYPE
Caterpillar
Caterpillar
6V5811
SEAL-LIP TYPE
Caterpillar
Caterpillar
6V5784
SEAL
Caterpillar
Caterpillar
6V5700
SEAL-O-RING
Caterpillar
Caterpillar
6V5380
SEAL-LIP TYPE
Caterpillar
Caterpillar
6V5373
SEAL-O RING
Caterpillar