7L2181 SEAL OUTPUT BEARING RETAINER Caterpillar parts
24H, 24M, 3406, 3406B, 3408, 3512B, 824C, 824G, 824G II, 824H, 824K, 825G, 825G II, 825H, 825K, 826C, 826G, 826G II, 826H, 826K, 834B, 834G, 834H, 834K, 836, 836G, 836H, 836K, 980C, 980F, 980F II, 980...
Rating:
Alternative (cross code) number:
CA7L2181
7L-2181
7L2181
CA7L2181
7L-2181
7L2181
Weight: 0.05 pounds 0 kg.
Information:
CROSS SECTION DIAMETER
3.53
mm
DASH SIZE
262
ID
177.39
mm
MATERIAL
Polyacrylic Rubber - 75 Duro
OD
0
mm
ARTICULATED TRUCK, WHEEL LOADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 7L2181:
MARINE AUXILIARY
3512B
Information:
Loading of the Generator
When a generator is installed or reconnected, be sure that the total current in one phase does not exceed the nameplate rating. Each phase should carry the same load which allows the engine to work at the rated capacity. An electrical unbalance can result in an electrical overload and overheating if one-phase current exceeds the nameplate amperage.Allowable combinations of unbalanced loads are shown in Illustration 1. When you operate with significant single-phase loads, the combinations of single-phase load and three-phase load may be used. Such combinations should be located below the line on the graph.
Illustration 1 g00627416
Allowable Combinations of Unbalanced Loads
Block Loading
When an electrical load is applied to a generator set, block loading occurs. This load may be anywhere from a moderate percentage of the rated load up to the rated load.The block loading capability of a generator set depends on the following factors.
engine transient response
voltage regulator response
type of the voltage regulator
altitude of operation of the generator set
type of load
the amount of load that is already presentIf a block load derating is required, refer to ISO 3046 Standards or SAE J1349 Standards. Also, reference Engine Data Sheet, LEKX4066, "Loading Transient Response" and Engine Data Sheet, LEKX4067, "Block and Transient Response".Power Factor
The generator overall power factor represents the efficiency of the load. The power factor is the ratio of generator total apparent power to generator total real power. This ratio is expressed as a decimal. The power factor represents the portion of the current which is doing useful work. The portion of current which is not doing useful work is absorbed in maintaining the magnetic field in motors. This current is called the reactive load. Engine power is not required to maintain the reactive load.In most applications, electric motors and transformers determine the power factor of the system. Induction motors usually have a power factor that is no larger than 0.8. Incandescent lighting is a resistive load of about 1.0 power factor, or unity.The power factor of a system may be determined by a power factor meter or by calculations. Determine the power requirement in kW by multiplying the power factor by the kVA that is supplied to the system. As the power factor increases, the total current that is supplied to a constant power demand will decrease. With equal loads, a lower power factor will draw more current. A high-power factor will result in full engine load that is less than the generator rated amperage. A lower power factor increases the possibility of overloading the generator.Note: Normally, Cat generators are designed for a power factor of 0.8.Excitation Systems
Self-Excited Generators
Self-excited generators receive excitation power and regulator-voltage sensing from the generator main armature output. The voltage regulator senses the generator output voltage. A regulated output is provided to the generator exciter. This regulated output is provided by the voltage regulator. The exciter then provides power to the main rotating field. As the main field rotates, a voltage is induced into the main armature. This voltage is a
When a generator is installed or reconnected, be sure that the total current in one phase does not exceed the nameplate rating. Each phase should carry the same load which allows the engine to work at the rated capacity. An electrical unbalance can result in an electrical overload and overheating if one-phase current exceeds the nameplate amperage.Allowable combinations of unbalanced loads are shown in Illustration 1. When you operate with significant single-phase loads, the combinations of single-phase load and three-phase load may be used. Such combinations should be located below the line on the graph.
Illustration 1 g00627416
Allowable Combinations of Unbalanced Loads
Block Loading
When an electrical load is applied to a generator set, block loading occurs. This load may be anywhere from a moderate percentage of the rated load up to the rated load.The block loading capability of a generator set depends on the following factors.
engine transient response
voltage regulator response
type of the voltage regulator
altitude of operation of the generator set
type of load
the amount of load that is already presentIf a block load derating is required, refer to ISO 3046 Standards or SAE J1349 Standards. Also, reference Engine Data Sheet, LEKX4066, "Loading Transient Response" and Engine Data Sheet, LEKX4067, "Block and Transient Response".Power Factor
The generator overall power factor represents the efficiency of the load. The power factor is the ratio of generator total apparent power to generator total real power. This ratio is expressed as a decimal. The power factor represents the portion of the current which is doing useful work. The portion of current which is not doing useful work is absorbed in maintaining the magnetic field in motors. This current is called the reactive load. Engine power is not required to maintain the reactive load.In most applications, electric motors and transformers determine the power factor of the system. Induction motors usually have a power factor that is no larger than 0.8. Incandescent lighting is a resistive load of about 1.0 power factor, or unity.The power factor of a system may be determined by a power factor meter or by calculations. Determine the power requirement in kW by multiplying the power factor by the kVA that is supplied to the system. As the power factor increases, the total current that is supplied to a constant power demand will decrease. With equal loads, a lower power factor will draw more current. A high-power factor will result in full engine load that is less than the generator rated amperage. A lower power factor increases the possibility of overloading the generator.Note: Normally, Cat generators are designed for a power factor of 0.8.Excitation Systems
Self-Excited Generators
Self-excited generators receive excitation power and regulator-voltage sensing from the generator main armature output. The voltage regulator senses the generator output voltage. A regulated output is provided to the generator exciter. This regulated output is provided by the voltage regulator. The exciter then provides power to the main rotating field. As the main field rotates, a voltage is induced into the main armature. This voltage is a
Cat SIS web machinery list:
Parts seal Caterpillar catalog:
1672217
SEAL AS-BUFFER
1390, 2590, 320C, 322C, 324D, 324D L, 324E, 324E L, 324E LN, 325B L, 325C, 325C L, 325D, 325D L, 325D MH, 329D, 329D L, 329E, 330B L, 330C, 330C L, 330D, 330D FM, 330D L, 330D LN, 345B, 345B II, 345B ...
1390, 2590, 320C, 322C, 324D, 324D L, 324E, 324E L, 324E LN, 325B L, 325C, 325C L, 325D, 325D L, 325D MH, 329D, 329D L, 329E, 330B L, 330C, 330C L, 330D, 330D FM, 330D L, 330D LN, 345B, 345B II, 345B ...
1709864
SEAL-U-CUP
320C, 322B L, 322C, 322C FM, 323D L, 324D, 324D L, 324D LN, 324E, 324E L, 324E LN, 325B L, 325C, 325C FM, 325C L, 325D, 325D FM, 325D FM LL, 325D L, 328D LCR, 329D, 329D L, 329E, 330B L, 330C, 330C FM...
320C, 322B L, 322C, 322C FM, 323D L, 324D, 324D L, 324D LN, 324E, 324E L, 324E LN, 325B L, 325C, 325C FM, 325C L, 325D, 325D FM, 325D FM LL, 325D L, 328D LCR, 329D, 329D L, 329E, 330B L, 330C, 330C FM...
8C9179
SEAL AS
345C, 350, 350 L, 365B, 365B II, 365B L, 365C, 365C L, 365C L MH, 374D L, 374F L, 375, 375 L, 385B, 385C, 385C L, 390D, 390D L, 390F L, 5080, AD45B, CR20, P16
345C, 350, 350 L, 365B, 365B II, 365B L, 365C, 365C L, 365C L MH, 374D L, 374F L, 375, 375 L, 385B, 385C, 385C L, 390D, 390D L, 390F L, 5080, AD45B, CR20, P16
1362967
SEAL-O-RING
16M, 345B II, 345C, 345C L, 365B, 365B II, 365B L, 365C, 365C L, 365C L MH, 374D L, 374F L, AD30
16M, 345B II, 345C, 345C L, 365B, 365B II, 365B L, 365C, 365C L, 365C L MH, 374D L, 374F L, AD30
1672219
SEAL AS-BUFFER
834G, 834H, TK1051
834G, 834H, TK1051
5P5520
SEAL-LIP TYPE (168.43MM OD)
824G, 824G II, 824H, 826G, 826G II, 826H, 844, 844H, 844K, D8L, D9N, D9R
824G, 824G II, 824H, 826G, 826G II, 826H, 844, 844H, 844K, D8L, D9N, D9R
4J9964
SEAL
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12E, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M ...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12E, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M ...
8J2330
SEAL
120G, 120H, 120H ES, 120H NA, 12E, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 24H
120G, 120H, 120H ES, 120H NA, 12E, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 24H
1731007
SEAL
120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H,...
120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H,...
1010509
SEAL-INTEGRAL
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14H, 14H NA, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 16H, 16H NA, 24H
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14H, 14H NA, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 16H, 16H NA, 24H
1659954
SEAL-LIP TYPE
24H, 24M
24H, 24M
7L2180
SEAL SELECTOR COVER
3116, 3126, 3126B, 3208, 3304, 3306, 3406, 3406B, 3408, 3512B, D334, D342, D342C, D343, D346, D348, D353C, M313C, M313D, M315C, M315D, M315D 2, M316C, M316D, M317D 2, M318C, M318C MH, M318D, M318D MH,...
3116, 3126, 3126B, 3208, 3304, 3306, 3406, 3406B, 3408, 3512B, D334, D342, D342C, D343, D346, D348, D353C, M313C, M313D, M315C, M315D, M315D 2, M316C, M316D, M317D 2, M318C, M318C MH, M318D, M318D MH,...
7L2175
SEAL BREATHER
3208, 3306, 3406, 3406B, 3408, 3512B, 613, 613B, 613C, 613C II, D250D, D333A, D333B, D342, D342C, D343, D346, D348, D353C
3208, 3306, 3406, 3406B, 3408, 3512B, 613, 613B, 613C, 613C II, D250D, D333A, D333B, D342, D342C, D343, D346, D348, D353C
5L5885
SEAL DRIVE SPIDER TO FRONT BEARING RETAINER
3406, 3406B, 3408, 3512B, 545C, 561M, 561N, D342, D342C, D343, PL61
3406, 3406B, 3408, 3512B, 545C, 561M, 561N, D342, D342C, D343, PL61
5L5598
SEAL DRIVE SPIDER RETAINER
3406, 3406B, 3408, 3512B, D342, D342C, D343
3406, 3406B, 3408, 3512B, D342, D342C, D343
5L5596
SEAL OUTPUT FLANGE RETAINER
3406, 3406B, 3408, 3512B, D342, D342C, D343
3406, 3406B, 3408, 3512B, D342, D342C, D343
5H4894
SEAL OUTPUT FLANGE
3192, 3406, 3406B, 3408, 3412, 3512B, 583H, 7241, 7251, D342, D342C, D343, D348, D353C, D399, D9E
3192, 3406, 3406B, 3408, 3412, 3512B, 583H, 7241, 7251, D342, D342C, D343, D348, D353C, D399, D9E
2348937
SEAL-INTEGRAL
16G, 16H NA, 24H, 24M, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 365C, 365C L, 365C L MH, 374D ...
16G, 16H NA, 24H, 24M, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 365C, 365C L, 365C L MH, 374D ...
1259794
SEAL-O-RING
3408, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 525B, 525C, 535B, 535C, 545, 545C, 583T, 587T, 631D, 631E, 631G, 633E II, 637E, 637G, 651E, 6...
3408, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 525B, 525C, 535B, 535C, 545, 545C, 583T, 587T, 631D, 631E, 631G, 633E II, 637E, 637G, 651E, 6...
2395572
SEAL-INTEGRAL
24H, 3406B, 3406C, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 5110B, 621F, 621H, 623E, 623F, 627F, 631D, 631E, 631G, 633E II, 637E, 637G, 651E, 657E, 740B, 772, 773B, 773D, 773E, 773F, 773G...
24H, 3406B, 3406C, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 5110B, 621F, 621H, 623E, 623F, 627F, 631D, 631E, 631G, 633E II, 637E, 637G, 651E, 657E, 740B, 772, 773B, 773D, 773E, 773F, 773G...
1N6002
SEAL PLUG ON MANIFOLD ASSEMBLY
120G, 12G, 130G, 140G, 14G, 14H, 14H NA, 16, 160G, 16G, 16H, 16H NA, 24H, 3406, 3408, 561C, 561D, 768B, 768C, 769, 769C, 769D, 771C, 771D, 772, 772B, 773, 773B, 773D, 775B, 775D, 776, 776C, 776D, 777,...
120G, 12G, 130G, 140G, 14G, 14H, 14H NA, 16, 160G, 16G, 16H, 16H NA, 24H, 3406, 3408, 561C, 561D, 768B, 768C, 769, 769C, 769D, 771C, 771D, 772, 772B, 773, 773B, 773D, 775B, 775D, 776, 776C, 776D, 777,...
7L3348
SEAL PLUGS ON MOD. VALVE ASSEMBLY
3406, 3408, D343, D348
3406, 3408, D343, D348
5H5894
SEAL OUTPUT FLANGE
3406, 3408, D343
3406, 3408, D343