9T4057 SEAL-O-RING Caterpillar parts
120M, 120M 2, 12M, 12M 2, 140M, 140M 2, 14M, 160M, 160M 2, 16M, 24M, 789, 793, 928HZ, 930G, C18, C32, C4.4, M312, M313C, M315, M315C, M316C, M318, M318C, M318C MH, M320, M322C
Rating:
Alternative (cross code) number:
CA9T4057
9T-4057
9T4057
CA9T4057
9T-4057
9T4057
Weight: 0.01 pounds 0 kg.
Information:
CROSS SECTION DIAMETER
2
mm
ID
10
mm
MATERIAL
Nitrile (NBR) Rubber 90 Duro
OD
0
mm
GENERATOR SET, WHEELED EXCAVATOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
This part in 2 request:
Show.
This information for suppliers only!
2024-01-15
2023-12-27
Compatible equipment models: 9T4057:
Information:
System Operation Description:The following information must be known and recorded for paralleling operations. The information must be obtained at various load points. The information must match the generator readings.
Verify breaker outputs voltage
Current
Power
Power factor readingsThe following are what is expected:
Voltages are close to rated values
Reading from the EMCP and other devices match
No voltage exists on the output of the open breaker
Metering at various load points match the power analyzer readings
Metering at the output of breaker matches metering at input of breaker for paralleling
All power readings are positiveIf the expected data is not correct, then the following must be confirmed:
Check the settings in the EMCP
Check for correct wiring.
If negative kW is seen, check for correct CT polarityA non-adjustable and non-programmable shutdown immediately occurs when the generator breaker is closed and there is a generator sensing fault. This shutdown occurs when a phase difference (non-zero) between phase A on the generator and phase A on the bus is detected. An immediate shutdown test also occurs for the other phases.Test Step 1. Arbitration Line Wiring FaultConfirm the status of the arbitration line. Table 1 lists the invalid arbitration line states that are detected prior to arbitration.
Table 1
Arbitration Line States
Arbitration Relay Output (HWDBA #5) Pre-Arbitration Input (HWDBA #3) Post-Arbitration Input (HWDBA #4) Arbitration Condition Description Arbitration Line Wiring Fault (Check Prior to Arbitration)
FALSE FALSE FALSE Downstream from Arbitration Warning
FALSE FALSE TRUE Unacceptable State Shutdown
FALSE TRUE FALSE Unacceptable State Shutdown
FALSE TRUE TRUE Normal State No Action
TRUE FALSE FALSE Loss of Arbitration Warning
TRUE FALSE TRUE Unacceptable State Shutdown
TRUE TRUE FALSE Won Arbitration No Action
TRUE TRUE TRUE Unacceptable State Warning Expected Result:There are no arbitration line wiring faults.Results:
OK - No arbitration line wiring faults are present . Proceed to Test Step 2.
NOT OK - The generator set does not operate normally.Repair: Correct any wiring faults. Reset the generator set. Verify that the problem has been corrected. The generator set operates normally.STOPTest Step 2. DBA FailureA DBA failure can occur due to a warning or shutdown, depending on number of occurrences. Determine if any of the following conditions occurred.
Arbitration relay timer expired
Pre-arbitration and post-arbitration inputs did not maintain state
Close breaker timeout (The breaker tried to close but failed while others were making a request to close.)Expected Result:None of the preceding conditions are true.Results:
OK - None of the preceding conditions are true. Proceed to Test Step 3.
NOT OK - The generator set does not operate normally.Repair: Check that the setpoints are appropriate for the application.STOPTest Step 3. An HWDBA#1 Wire Short DiagnosticIf excess current is required to pull down the "Requesting Line", then an HWDBA code will be generated.Expected Result:Excess current does not exist on the "Requesting Line".Results:
OK - Excess current did not pull the "Requesting Line" down. Proceed to Test Step 4.
Not OK - Repair: Repair the requesting line wiring. Verify that the problem has been corrected.STOPTest Step 4. HWDBA #2 Wire Short DiagnosticIf excess current is required to pull down the "Capturing Line", then an HWDBA #2 code will be generated.Expected Result:Excess current does not exist
Verify breaker outputs voltage
Current
Power
Power factor readingsThe following are what is expected:
Voltages are close to rated values
Reading from the EMCP and other devices match
No voltage exists on the output of the open breaker
Metering at various load points match the power analyzer readings
Metering at the output of breaker matches metering at input of breaker for paralleling
All power readings are positiveIf the expected data is not correct, then the following must be confirmed:
Check the settings in the EMCP
Check for correct wiring.
If negative kW is seen, check for correct CT polarityA non-adjustable and non-programmable shutdown immediately occurs when the generator breaker is closed and there is a generator sensing fault. This shutdown occurs when a phase difference (non-zero) between phase A on the generator and phase A on the bus is detected. An immediate shutdown test also occurs for the other phases.Test Step 1. Arbitration Line Wiring FaultConfirm the status of the arbitration line. Table 1 lists the invalid arbitration line states that are detected prior to arbitration.
Table 1
Arbitration Line States
Arbitration Relay Output (HWDBA #5) Pre-Arbitration Input (HWDBA #3) Post-Arbitration Input (HWDBA #4) Arbitration Condition Description Arbitration Line Wiring Fault (Check Prior to Arbitration)
FALSE FALSE FALSE Downstream from Arbitration Warning
FALSE FALSE TRUE Unacceptable State Shutdown
FALSE TRUE FALSE Unacceptable State Shutdown
FALSE TRUE TRUE Normal State No Action
TRUE FALSE FALSE Loss of Arbitration Warning
TRUE FALSE TRUE Unacceptable State Shutdown
TRUE TRUE FALSE Won Arbitration No Action
TRUE TRUE TRUE Unacceptable State Warning Expected Result:There are no arbitration line wiring faults.Results:
OK - No arbitration line wiring faults are present . Proceed to Test Step 2.
NOT OK - The generator set does not operate normally.Repair: Correct any wiring faults. Reset the generator set. Verify that the problem has been corrected. The generator set operates normally.STOPTest Step 2. DBA FailureA DBA failure can occur due to a warning or shutdown, depending on number of occurrences. Determine if any of the following conditions occurred.
Arbitration relay timer expired
Pre-arbitration and post-arbitration inputs did not maintain state
Close breaker timeout (The breaker tried to close but failed while others were making a request to close.)Expected Result:None of the preceding conditions are true.Results:
OK - None of the preceding conditions are true. Proceed to Test Step 3.
NOT OK - The generator set does not operate normally.Repair: Check that the setpoints are appropriate for the application.STOPTest Step 3. An HWDBA#1 Wire Short DiagnosticIf excess current is required to pull down the "Requesting Line", then an HWDBA code will be generated.Expected Result:Excess current does not exist on the "Requesting Line".Results:
OK - Excess current did not pull the "Requesting Line" down. Proceed to Test Step 4.
Not OK - Repair: Repair the requesting line wiring. Verify that the problem has been corrected.STOPTest Step 4. HWDBA #2 Wire Short DiagnosticIf excess current is required to pull down the "Capturing Line", then an HWDBA #2 code will be generated.Expected Result:Excess current does not exist
Cat SIS web machinery list:
Parts seal Caterpillar catalog:
8D4217
SEAL
14G, 14H, 14H NA, 14M
14G, 14H, 14H NA, 14M
8D3308
SEAL
14G, 14H, 14H NA, 14M, 16G, 16H, 16H NA, 16M
14G, 14H, 14H NA, 14M, 16G, 16H, 16H NA, 16M
5P8847
SEAL-LIP TYPE
14M, 16G, 16H, 16H NA, 16M
14M, 16G, 16H, 16H NA, 16M
9D6588
SEAL-LIP TYPE
16G, 16H, 16H NA, 16M
16G, 16H, 16H NA, 16M
8D3307
SEAL
16G, 16H, 16H NA, 16M
16G, 16H, 16H NA, 16M
3290411
SEAL-LIP TYPE
120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 160H, 160K, 160M, 160M 2, 163H
120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 160H, 160K, 160M, 160M 2, 163H
2035957
SEAL
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14M, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 16M
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14M, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 16M
1731007
SEAL
120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H,...
120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H,...
1659954
SEAL-LIP TYPE
24H, 24M
24H, 24M
1668815
SEAL GP-FINAL DRIVE
24H, 24M
24H, 24M
3048797
SEAL-BONDED
C4.4, C6.6, C7.1
C4.4, C6.6, C7.1
2657808
SEAL-O-RING
C4.4
C4.4
2637541
SEAL-O-RING
C4.4, C6.6, C7.1
C4.4, C6.6, C7.1
2621046
SEAL-O-RING
3056E, 550B, 560B, 574B, 924G, 924GZ, 930G, C4.4, IT28G, M316C, M318C, M318C MH, M322C
3056E, 550B, 560B, 574B, 924G, 924GZ, 930G, C4.4, IT28G, M316C, M318C, M318C MH, M322C
2287092
SEAL-O-RING
120M 2, 12M 2, 12M 3 AWD, 140M, 140M 2, 140M 3 AWD, 160M, 160M 2, 160M 3 AWD, 2470C, 2570C, 2670C, 2864C, 311D LRR, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 312E, 312E L, 313D, 313D2, 313D2 LGP, 314D C...
120M 2, 12M 2, 12M 3 AWD, 140M, 140M 2, 140M 3 AWD, 160M, 160M 2, 160M 3 AWD, 2470C, 2570C, 2670C, 2864C, 311D LRR, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 312E, 312E L, 313D, 313D2, 313D2 LGP, 314D C...
3090720
SEAL-O-RING
C4.4, C6.6, C9
C4.4, C6.6, C9
1429445
SEAL
3306B, 3406C, 3406E, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B
3306B, 3406C, 3406E, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B
2364889
SEAL
120M, 3412C, 966H, C27, C32
120M, 3412C, 966H, C27, C32
2675649
SEAL
3412, 3412C, 3512, 3512B, 3516, 3516B, C2.2, C3.3, C4.4, C6.6, C7.1
3412, 3412C, 3512, 3512B, 3516, 3516B, C2.2, C3.3, C4.4, C6.6, C7.1
2646409
SEAL
3412, 3412C, 3508, 3508B, 3512, 3512B, 3516, 3516B, C1.5, C2.2, C3.3, C4.4, C6.6, C7.1
3412, 3412C, 3508, 3508B, 3512, 3512B, 3516, 3516B, C1.5, C2.2, C3.3, C4.4, C6.6, C7.1
5P5950
SEAL
215, 215B, 215C, 215D, 225, 231D, 235, 235B, 235C, 245, 24H, 3412C, 69D, 769D, 771D, 773D, 773E, 775D, 775E, 776D, 777D, 793F AC, 795F AC, 795F XQ, C27, C32, D10R, D11R, D9R
215, 215B, 215C, 215D, 225, 231D, 235, 235B, 235C, 245, 24H, 3412C, 69D, 769D, 771D, 773D, 773E, 775D, 775E, 776D, 777D, 793F AC, 795F AC, 795F XQ, C27, C32, D10R, D11R, D9R
7E4369
SEAL AS-EXHAUST
3412, 3412C, AD45B, AD55, PM3412
3412, 3412C, AD45B, AD55, PM3412