9X7694 SEAL-LIP TYPE Caterpillar parts
Rating:
Alternative (cross code) number:
CA9X7694
9X-7694
9X7694
CA9X7694
9X-7694
9X7694
Weight: 0.05 pounds 0 kg.
Information:
AXIAL WIDTH
9
mm
BORE DIAMETER
0
mm
CONSTRUCTION TYPE
DB
MATERIAL
FKM Rubber - 80 Duro
SEAL OD
70
mm
SHAFT OD
55
mm
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
FPE - Forklift Metal Seal - Oil Mitsubishi-Caterpillar 9X7694 Hacus Aftermarket - New
Hacus Forklift Metal Seal - Oil Mitsubishi-Caterpillar 9X7694 Hacus Quality After Market Part || Hacus Branded After Market Forklift parts are manufactured for Quality & Performane || Hacus Products come with a 6 Month Manufacturer's Warranty || Hacus product line guarantees reliability, effectiveness, and sustainability while also striving to be the lowest cost in the market || Best quality of parts for your lift truck while always putting your safety first
Hacus Forklift Metal Seal - Oil Mitsubishi-Caterpillar 9X7694 Hacus Quality After Market Part || Hacus Branded After Market Forklift parts are manufactured for Quality & Performane || Hacus Products come with a 6 Month Manufacturer's Warranty || Hacus product line guarantees reliability, effectiveness, and sustainability while also striving to be the lowest cost in the market || Best quality of parts for your lift truck while always putting your safety first
$15.25
02 Sep 2021
0.05[0.02] Pounds
Amazon.com
FPE - HACUS New Forklift METAL SEAL - OIL Replacement part for MITSUBISHI-CATERPILLAR 9X7694
Hacus Part Quality: Aftermarket || Condition: New || Free Ground Shipping if your order is $475 or more!
Hacus Part Quality: Aftermarket || Condition: New || Free Ground Shipping if your order is $475 or more!
Information:
Procedure to Check Nitrogen Charge in Accumulator When Adjusting Track Tension:
1. Charge the tensioner group to a minimum of 17 200 kPa (2500 psi) using the 1U-9058 Hose Group, then close the gate valve. Stop the engine and place the control lever in the FLOAT position.2. Open the gate valve enough to slowly relieve the tensioner pressure. The gauge pressure should steadily decrease from 17 200 kPa (2500 psi) until a rapid drop in pressure occurs. Record the pressure at which the rapid pressure drop occurred and the resulting pressure immediately after the rapid pressure drop. Close the gate valve.The pressure at which the rapid drop occurs is the approximate dry nitrogen precharge of the accumulator. The rapid pressure drop should occur between 10 000 and 12 000 kPa (1450 and 1750 psi) and drop rapidly at a maximum of 1400 kPa (200 psi). If the range of the rapid pressure drop exceeds 1400 kPa (200 psi), the pressure was bled too quickly. An inaccurate pressure reading will result. Recharge and rebleed the tensioner group to obtain a better reading. The slower the bleed rate, the more accurate the pressure measurements will be.
3. If the rapid pressure drop occurs below 10 000 kPa (1450 psi) or does not occur at all, the accumulator requires service or replacement.
Do NOT operate the machine with an accumulator that has an inadequate nitrogen charge. The accumulator functions as a spring for the undercarriage to recoil. Machine operation with an inadequate nitrogen charge could result in undercarriage damage and/or steering difficulty.
1. Charge the tensioner group to a minimum of 17 200 kPa (2500 psi) using the 1U-9058 Hose Group, then close the gate valve. Stop the engine and place the control lever in the FLOAT position.2. Open the gate valve enough to slowly relieve the tensioner pressure. The gauge pressure should steadily decrease from 17 200 kPa (2500 psi) until a rapid drop in pressure occurs. Record the pressure at which the rapid pressure drop occurred and the resulting pressure immediately after the rapid pressure drop. Close the gate valve.The pressure at which the rapid drop occurs is the approximate dry nitrogen precharge of the accumulator. The rapid pressure drop should occur between 10 000 and 12 000 kPa (1450 and 1750 psi) and drop rapidly at a maximum of 1400 kPa (200 psi). If the range of the rapid pressure drop exceeds 1400 kPa (200 psi), the pressure was bled too quickly. An inaccurate pressure reading will result. Recharge and rebleed the tensioner group to obtain a better reading. The slower the bleed rate, the more accurate the pressure measurements will be.
3. If the rapid pressure drop occurs below 10 000 kPa (1450 psi) or does not occur at all, the accumulator requires service or replacement.
Do NOT operate the machine with an accumulator that has an inadequate nitrogen charge. The accumulator functions as a spring for the undercarriage to recoil. Machine operation with an inadequate nitrogen charge could result in undercarriage damage and/or steering difficulty.
Parts seal Caterpillar catalog:
9X7687
SEAL-LIP TYPE
Caterpillar
Caterpillar
9X7561
SEAL GP-
Caterpillar
Caterpillar
9X7560
SEAL GP-
Caterpillar
Caterpillar
9X7555
SEAL-LIP TYPE
Caterpillar
Caterpillar
9X7551
SEAL-O RING
Caterpillar
Caterpillar
9X7548
SEAL
Caterpillar
Caterpillar
9X7729
SEAL-LIP TYPE
Caterpillar
Caterpillar
9X7723
SEAL-O RING
Caterpillar
Caterpillar
9X7705
SEAL AS
Caterpillar
Caterpillar
9X7704
SEAL-O RING
Caterpillar
Caterpillar
9X7698
SEAL
Caterpillar
Caterpillar
9X7695
SEAL-LIP TYPE
Caterpillar
Caterpillar