OPERATOR STATION
PANEL GPOPERATOR STATION
PANEL GP#SEBP21961010
130-7237: PANEL AR-CONTROL
130-7237 PANEL AR-CONTROL
S/N 9AB1945-UP
GENERATOR MOUNTED. EMCP II
FOR USAGE REFER TO CHART @@@@@129-4053@@@@@
AN ATTACHMENT
S/N 9AB1945-UP
GENERATOR MOUNTED. EMCP II
FOR USAGE REFER TO CHART @@@@@129-4053@@@@@
AN ATTACHMENT
Parts for your 3304 GEN SET ENGINE:
CATERPILLAR SIS| Pos. | Part No | Qty | Parts name | Comments |
|---|---|---|---|---|
| 7E-1234 Y | [1] | MODULE GP-ALARM | ||
| 9Y-2906 Y | [1] | MODULE GP-ALARM | ||
| 9Y-2907 Y | [1] | MODULE GP-ALARM | ||
| 101-0225 Y | [1] | CONTROL GP-EMCP ELECTRONIC | ||
| 118-0175 Y | [1] | CONTROL GP-EMCP ELECTRONIC (AC TRANSFORMER BOX) | ||
| 118-2070 Y | [1] | CONTROL GP-EMCP ELECTRONIC (GENERATOR SET CONTROL +) | ||
| 133-6350 Y | [1] | CONTROL GP-EMCP ELECTRONIC (GENERATOR SET CONTROL) | ||
| 7E-8396 Y | [1] | CONTROL GP-FUEL | ||
| -OR- | ||||
| 191-8573 CY | [1] | CONTROL GP-SOLENOID | ||
| 4P-2788 Y | [1] | GOVERNOR AS-ELECTRONIC | ||
| 4W-9313 Y | [1] | GOVERNOR AS-ELECTRONIC | ||
| 4W-9314 Y | [1] | GOVERNOR AS-ELECTRONIC | ||
| 7E-1232 Y | [1] | GOVERNOR AS-ELECTRONIC | ||
| 106-5171 Y | [1] | MODULE GP-SYNCHRONIZING LIGHTS | ||
| 106-5169 Y | [1] | MODULE GP-SYNCHRONIZING LIGHTS | ||
| 128-3326 Y | [1] | RELAY GP (24-VOLT) | ||
| 103-8975 Y | [1] | SEAL GP-ENCLOSURE | ||
| 111-7760 Y | [1] | SHUTOFF GP-ELECTRICAL | ||
| 111-7761 Y | [1] | SHUTOFF GP-ELECTRICAL | ||
| 5N-9117 | [3] | ADAPTER | ||
| 204-9553 C | [1] | BAR GP-GROUND | ||
| 4B-2049 | [4] | NUT (10-32-THD) | ||
| 8F-1434 | [4] | LOCKWASHER | ||
| 103-6197 | [1] | BLOCK-TERMINAL | ||
| 204-9552 | [1] | BAR-GROUND | ||
| 103-6197 | [1] | BLOCK-TERMINAL | ||
| 104-2994 | [1] | BLOCK-TERMINAL | ||
| 8T-2501 | [2] | BOLT (3/8-16X2-IN) | ||
| 204-0747 C | [1] | BOX AS | ||
| 1N-9770 | [1] | CIRCUIT BREAKER AS (12.5-AMPERE) | ||
| 6V-8376 | [2] | SCREW-MACHINE (8-32X0.25-IN) | ||
| 9B-7233 | [2] | LOCKWASHER | ||
| 200-8577 | [1] | CIRCUIT BREAKER AS (20-AMPERE) | ||
| 6V-8376 | [2] | SCREW-MACHINE (8-32X0.25-IN) | ||
| 9B-7233 | [2] | LOCKWASHER | ||
| 4P-2162 | [3] | CLIP | ||
| 5N-9072 | [3] | CLIP | ||
| 5N-9067 | [3] | COLLAR | ||
| 6V-5817 D | CONDUIT-FLEXIBLE (26.1-MM ID, SPLIT)(2-M) | |||
| 2W-4899 | [1] | DIODE AS | ||
| 5N-4988 | [1] | DIODE AS | ||
| 9Y-8412 | [1] | DIODE AS | ||
| 103-1837 | [1] | FILM-CONTROL PANEL (MANUAL STARTING AID) | ||
| 103-1838 | [1] | FILM-CONTROL PANEL (AUTO STARTING AID) | ||
| 202-4234 C | [1] | FILM-IDENTIFICATION (CONTROL PANEL) | ||
| 106-9926 | [1] | FILM-IDENTIFICATION (TERMINAL) | ||
| 7C-4062 | [1] | FILM-IDENTIFICATION (REVERSE POWER) | ||
| 9Y-9782 | [1] | FILM-IDENTIFICATION (10-AMPERE FUSE) | ||
| 9Y-9783 | [1] | FILM-IDENTIFICATION (2-AMPERE FUSE) | ||
| 7C-0974 | [1] | FILM-WARNING (ELECTRICAL SHOCK HAZARD) | ||
| 3K-8782 | [16] | FUSE (10-AMPERE) | ||
| 7W-0482 | [3] | FUSE (2-AMPERE) | ||
| 8T-2882 | [1] | HANDLE-PULL | ||
| 4W-5972 | [1] | KNOB | ||
| 7N-5876 | [2] | LAMP (24-VOLT, 0.2-AMPERE)(CLEAR) | ||
| 7G-9730 | [2] | LAMP AS (120-VOLT, 3-WATT)(CLEAR) | ||
| 062-5388 | [3] | LOCKNUT (1-11-1/2-THD) | ||
| 4D-1326 | [2] | LOCKWASHER (EXTERNAL TOOTH) | ||
| 8C-7507 | [4] | LOCKWASHER | ||
| 8F-1434 C | [2] | LOCKWASHER | ||
| 3N-5611 | [2] | MOUNT AS | ||
| 7C-6121 | [2] | MOUNT-FLEXIBLE | ||
| 4B-2049 | [4] | NUT (10-32-THD) | ||
| 6V-8801 | [2] | NUT (3/8-16-THD) | ||
| 4B-2047 C | [1] | NUT (10-24-THD) | ||
| 7C-1009 | [1] | PLATE AS-COVER | ||
| 155-2260 C | [1] | KIT-CONNECTING PLUG (3-PIN) | ||
| (INCLUDES PLUG AS & WEDGE) | ||||
| 155-2274 C | [1] | KIT-CONNECTING PLUG (6-PIN) | ||
| (INCLUDES PLUG AS & WEDGE) | ||||
| 5P-4935 | [2] | PLUG-BUTTON | ||
| 129-0308 | [1] | POTENTIOMETER (2-WATT)(VOLTAGE ADJUST) | ||
| 127-9070 | [1] | POTENTIOMETER (10,000-OHM)(VOLTAGE ADJUST) | ||
| 102-8806 | [1] | KIT-RECEPTACLE (8-PIN) | ||
| (INCLUDES RECEPTACLE AS & WEDGE) | ||||
| 112-7959 | [1] | RELAY-TIME DELAY (OVERCURRENT) | ||
| 123-4944 | [1] | RELAY-TIME DELAY | ||
| 123-4945 | [1] | RELAY-TIME DELAY | ||
| 123-4946 | [1] | RELAY-TIME DELAY | ||
| 123-4947 | [1] | RELAY-TIME DELAY | ||
| 126-0558 | [1] | RELAY-TIME DELAY | ||
| 5N-5510 | [1] | RELAY-REVERSE POWER | ||
| 7C-4378 | [1] | RELAY-REVERSE POWER | ||
| 3N-5981 | [1] | RHEOSTAT | ||
| 134-3846 | [1] | RHEOSTAT | ||
| 2N-3479 | [4] | SCREW (10-24X0.5-IN) | ||
| 4P-2161 | [3] | SCREW | ||
| 7M-9910 C | [1] | SCREW-MACHINE (10-24X1-IN) | ||
| 6V-6640 | [1] | SEALANT | ||
| 7C-9179 | [1] | STRIP-TERMINAL | ||
| -OR- | ||||
| 4D-1260 | [1] | STRIP AS-TERMINAL | ||
| 103-1836 | [1] | FILM-TERMINAL STRIP | ||
| -OR- | ||||
| 141-2064 | [1] | FILM-IDENTIFICATION (TERMINAL MARKER) | ||
| 5N-5159 | [2] | JUMPER-STRIP | ||
| 9X-8124 | [2] | SWITCH AS-MAGNETIC (24-VOLT)(STARTING MOTOR) | ||
| -OR- | ||||
| 175-2306 C | [2] | SWITCH AS-MAGNETIC (24-VOLT)(STARTING MOTOR) | ||
| 8C-9812 | [1] | SWITCH AS-TOGGLE (ETHER STARTING AID) | ||
| 3L-8187 | [3] | LOCKWASHER | ||
| 6T-3631 | [2] | NUT-HEX (15/32-32-THD) | ||
| 6T-3632 | [1] | LOCKWASHER | ||
| 6T-3633 | [1] | RING-LOCKING | ||
| 6V-8374 | [3] | SCREW-MACHINE (6-32X0.25-IN) | ||
| 8D-2676 | [1] | SWITCH AS-TOGGLE (SINGLE POLE)(ENGINE LIGHTS) | ||
| 3L-8187 | [2] | LOCKWASHER | ||
| 6T-3631 | [2] | NUT-HEX (15/32-32-THD) | ||
| 6T-3632 | [1] | LOCKWASHER | ||
| 6T-3633 | [1] | RING-LOCKING | ||
| 6V-8374 | [2] | SCREW-MACHINE (6-32X0.25-IN) | ||
| 7N-8008 | [1] | SWITCH AS-TOGGLE (CRANKCASE GUARD CONTROL) | ||
| 3L-8187 | [6] | LOCKWASHER | ||
| 6T-3631 | [2] | NUT-HEX (15/32-32-THD) | ||
| 6T-3632 | [1] | LOCKWASHER | ||
| 6T-3633 | [1] | RING-LOCKING | ||
| 6V-8374 | [6] | SCREW-MACHINE (6-32X0.25-IN) | ||
| 3N-5979 | [1] | SWITCH-ROTARY (4-POSITION)(ENGINE CONTROL SWITCH) | ||
| 9D-3721 | [1] | SWITCH-TOGGLE (SINGLE POLE)(MONITORING SYSTEM SERVICE) | ||
| 4W-8102 | [3] | TRANSFORMER-CURRENT (RATIO 150:5) | ||
| 5N-5429 | [3] | TRANSFORMER-CURRENT (RATIO 100:5) | ||
| 5N-5431 | [3] | TRANSFORMER-CURRENT (RATIO 300:5) | ||
| 5N-5432 | [3] | TRANSFORMER-CURRENT (RATIO 400:5) | ||
| 5N-5433 | [3] | TRANSFORMER-CURRENT (RATIO 600:5) | ||
| 5N-5434 | [3] | TRANSFORMER-CURRENT (RATIO 800:5) | ||
| 6I-1952 | [3] | TRANSFORMER (RATIO 600:5) | ||
| 7E-1112 | [3] | TRANSFORMER (RATIO 800:5) | ||
| 7E-1113 | [3] | TRANSFORMER (RATIO 1000:5) | ||
| 7E-1114 | [3] | TRANSFORMER (RATIO 1200:5) | ||
| 7E-1115 | [3] | TRANSFORMER (RATIO 1500:5) | ||
| 7E-1116 | [3] | TRANSFORMER (RATIO 2000:5) | ||
| 7E-1117 | [3] | TRANSFORMER (RATIO 2500:5) | ||
| 7E-1118 | [3] | TRANSFORMER (RATIO 3000:5) | ||
| 7E-1119 | [3] | TRANSFORMER (RATIO 4000:5) | ||
| 7W-6598 | [3] | TRANSFORMER (RATIO 3000:5) | ||
| 7W-7805 | [3] | TRANSFORMER (RATIO 4000:5) | ||
| 7W-8835 | [3] | TRANSFORMER (RATIO 2500:5) | ||
| 7W-8837 | [3] | TRANSFORMER-CURRENT (RATIO 1500:5) | ||
| 7W-8838 | [3] | TRANSFORMER-CURRENT (RATIO 1200:5) | ||
| 7W-8839 | [3] | TRANSFORMER-CURRENT (RATIO 1000:5) | ||
| 5N-5430 | [3] | TRANSFORMER-CURRENT (RATIO 200:5) | ||
| 7W-8836 | [3] | TRANSFORMER AS-CURRENT (RATIO 2000:5) | ||
| 4B-4274 | [4] | WASHER (5.5X13X1.2-MM THK) | ||
| 4P-2160 | [3] | RING-RETAINING (RETAINING RING) | ||
| 205-3109 C | [1] | WIRE AS | ||
| 6A-5067 B | [1] | RING-TERMINAL | ||
| 3T-4692 | TERMINAL-RING (6-GA, 7/16-IN SCREW) | |||
| -OR- | ||||
| 3T-4693 B | TERMINAL-RING (8-GA, 7/16-IN SCREW) | |||
| B | USE AS REQUIRED | |||
| C | CHANGE FROM PREVIOUS TYPE | |||
| D | ORDER BY THE METER | |||
| R | REMANUFACTURED PART MAY BE AVAILABLE | |||
| Y | SEPARATE ILLUSTRATION | |||
#SEBP21961011
7C-0174: PANEL AR-CONTROL
7C-0174 PANEL AR-CONTROL
S/N 83Z3096-UP
FOR USAGE REFER TO CHART 7C-1000 CHART-CONTROL PANEL
AN ATTACHMENT
S/N 83Z3096-UP
FOR USAGE REFER TO CHART 7C-1000 CHART-CONTROL PANEL
AN ATTACHMENT
Parts for your 3304 GEN SET ENGINE:
CATERPILLAR SIS| Pos. | Part No | Qty | Parts name | Comments |
|---|---|---|---|---|
| 9Y-2906 Y | [1] | MODULE GP-ALARM (NFPA 110) | ||
| 9Y-2907 Y | [1] | MODULE GP-ALARM (NFPA 99) | ||
| 7E-1234 Y | [1] | MODULE GP-ALARM (ALARM) | ||
| 7T-9868 Y | [1] | CONTROL GP-EMCP ELECTRONIC (AC METERING) | ||
| 6V-6155 Y | [1] | CONTROL GP-EMCP ELECTRONIC (ECM) | ||
| 7E-8396 Y | [1] | CONTROL GP-FUEL | ||
| 7E-1232 Y | [1] | GOVERNOR AS-ELECTRONIC (1724, 8290) | ||
| 4P-2788 Y | [1] | GOVERNOR AS-ELECTRONIC (2301A) | ||
| 4W-9313 Y | [1] | GOVERNOR AS-ELECTRONIC (2301) | ||
| 4W-9314 Y | [1] | GOVERNOR AS-ELECTRONIC (2301, PREREGULATOR) | ||
| 7C-1002 Y | [1] | MODULE GP-SYNCHRONIZING LIGHTS (480-VOLT) | ||
| 7C-4725 Y | [1] | MODULE GP-SYNCHRONIZING LIGHTS (600-VOLT) | ||
| 7C-3527 Y | [1] | SEAL GP-ENCLOSURE | ||
| 200-8577 | [1] | CIRCUIT BREAKER AS (20-AMPERE) | ||
| 6V-8376 | [2] | SCREW-MACHINE (8-32X0.25-IN) | ||
| 9B-7233 | [2] | LOCKWASHER | ||
| 1N-9770 | [1] | CIRCUIT BREAKER AS (12.5-AMPERE) | ||
| 6V-8376 | [2] | SCREW-MACHINE (8-32X0.25-IN) | ||
| 9B-7233 | [2] | LOCKWASHER | ||
| 2W-4899 | [1] | DIODE AS | ||
| 5N-4988 | [1] | DIODE AS | ||
| 9Y-8412 | [1] | DIODE AS | ||
| 3N-5611 | [2] | MOUNT AS | ||
| 7C-1009 | [1] | PLATE AS-COVER | ||
| 3N-5714 | [1] | RELAY AS (24-VOLT) | ||
| 7G-9730 | [2] | LAMP AS (120-VOLT, 3-WATT) | ||
| (EACH INCLUDES) | ||||
| 6V-8367 | [1] | LOCKWASHER | ||
| 6V-8382 | [1] | NUT-HEX (11/16-27-THD) | ||
| 9X-9724 | [2] | SWITCH AS-MAGNETIC | ||
| (EACH INCLUDES) | ||||
| 8T-4134 M | [2] | NUT (M6X1-THD) | ||
| 2W-8798 | [1] | SWITCH AS-PUSH BUTTON (EMERGENCY STOP) | ||
| 8C-9812 | [1] | SWITCH AS-TOGGLE (STARTING AID) | ||
| 3L-8187 | [3] | LOCKWASHER | ||
| 6T-3631 | [2] | NUT-HEX (15/32-32-THD) | ||
| 6T-3632 | [1] | LOCKWASHER | ||
| 6T-3633 | [1] | RING-LOCKING | ||
| 6V-8374 | [3] | SCREW-MACHINE (6-32X0.25-IN) | ||
| 7N-8008 | [1] | SWITCH AS-TOGGLE (GOVERNOR) | ||
| 3L-8187 | [6] | LOCKWASHER | ||
| 6T-3631 | [2] | NUT-HEX (15/32-32-THD) | ||
| 6T-3632 | [1] | LOCKWASHER | ||
| 6T-3633 | [1] | RING-LOCKING | ||
| 6V-8374 | [6] | SCREW-MACHINE (6-32X0.25-IN) | ||
| 8D-2676 | [1] | SWITCH AS-TOGGLE (SINGLE POLE)(PANEL LIGHT) | ||
| 3L-8187 | [2] | LOCKWASHER | ||
| 6T-3631 | [2] | NUT-HEX (15/32-32-THD) | ||
| 6T-3632 | [1] | LOCKWASHER | ||
| 6T-3633 | [1] | RING-LOCKING | ||
| 6V-8374 | [2] | SCREW-MACHINE (6-32X0.25-IN) | ||
| 8T-9637 | [1] | SWITCH AS-TOGGLE (MANUAL START) | ||
| 3L-8187 | [4] | LOCKWASHER | ||
| 6T-3631 | [2] | NUT-HEX (15/32-32-THD) | ||
| 6T-3632 | [1] | LOCKWASHER | ||
| 6T-3633 | [1] | RING-LOCKING | ||
| 6V-8374 | [4] | SCREW-MACHINE (6-32X0.25-IN) | ||
| 5N-9117 | [2] | ADAPTER | ||
| 2W-8683 | [1] | BLOCK-CONTACT | ||
| 3N-5977 | [1] | BLOCK-FUSE (30-AMPERE) | ||
| 7T-0037 | [3] | FUSE (0.75-AMPERE) | ||
| 4P-2162 | [2] | CLIP | ||
| 5N-9072 | [2] | CLIP | ||
| 5N-9067 | [2] | COLLAR | ||
| 6V-5817 D | CONDUIT-FLEXIBLE (26.1-MM ID, SPLIT)(1.2-M) | |||
| 9Y-4336 | [1] | FILM (CSA CONTROL PANEL APPROVAL) | ||
| 7W-9800 | [1] | FILM-CONTROL PANEL (EMERGENCY STOP) | ||
| 9Y-9782 | [1] | FILM-IDENTIFICATION (10-AMPERE FUSE) | ||
| 9Y-9783 | [1] | FILM-IDENTIFICATION (2-AMPERE FUSE) | ||
| 7C-4062 | [1] | FILM-IDENTIFICATION (REVERSE POWER) | ||
| 9Y-9771 | [1] | FILM-IDENTIFICATION (CONTROL PANEL) | ||
| 4W-8228 | [1] | FILM-IDENTIFICATION (TERMINAL MARKER) | ||
| 7C-0974 | [1] | FILM-WARNING (ELECTRICAL SHOCK HAZARD) | ||
| 3K-8782 | [16] | FUSE (10-AMPERE) | ||
| 7W-0482 | [3] | FUSE (2-AMPERE) | ||
| 7C-2952 | [1] | GASKET-MODULE (ENGINE CONTROL) | ||
| 7C-2953 | [1] | GASKET-MODULE (METERING) | ||
| 7C-2954 | [2] | GASKET-MODULE (ALARM, SYNCHRONIZING) | ||
| 8T-2882 | [1] | HANDLE-PULL | ||
| 4W-5972 | [1] | KNOB | ||
| 7N-5876 | [2] | LAMP (24-VOLT, 0.2-AMPERE) | ||
| 062-5388 | [2] | LOCKNUT (1-11-1/2-THD) | ||
| 8C-7507 | [4] | LOCKWASHER | ||
| 7C-6121 | [2] | MOUNT-FLEXIBLE | ||
| 4B-2049 | [4] | NUT (10-32-THD) | ||
| 5P-4935 | [2] | PLUG-BUTTON | ||
| 127-9070 | [1] | POTENTIOMETER (10,000-OHM) | ||
| 5N-5510 | [1] | RELAY-REVERSE POWER (120-VOLT TO 460-VOLT) | ||
| 7C-4378 | [1] | RELAY-REVERSE POWER (600-VOLT) | ||
| 3N-5981 | [1] | RHEOSTAT | ||
| 134-3846 | [1] | RHEOSTAT | ||
| 4P-2160 | [2] | RING-RETAINING (RETAINING RING) | ||
| 2N-3479 | [4] | SCREW (10-24X0.5-IN) | ||
| 4P-2161 | [2] | SCREW | ||
| 7C-4550 | [2] | SEAL (ROTATING SHAFT) | ||
| 7C-4910 | [2] | SEAL | ||
| 6V-6640 B | [1] | SEALANT | ||
| 4W-8787 | [1] | SOCKET-RELAY | ||
| 7C-5075 | [2] | STRIP-DUST SEAL (HORIZONTAL) | ||
| 7C-5076 | [2] | STRIP-DUST SEAL (VERTICAL) | ||
| 4L-6470 | [1] | STRIP AS-TERMINAL | ||
| 6V-8376 | [24] | SCREW-MACHINE (8-32X0.25-IN) | ||
| 3N-5976 | [1] | SWITCH (PHASE SELECT) | ||
| 3N-5979 | [1] | SWITCH-ROTARY (4-POSITION) | ||
| 9D-3721 | [1] | SWITCH-TOGGLE (SINGLE POLE)(STARTING AID) | ||
| 4W-8102 | [3] | TRANSFORMER-CURRENT (RATIO 150:5) | ||
| 5N-5429 | [3] | TRANSFORMER-CURRENT (RATIO 100:5) | ||
| 5N-5431 | [3] | TRANSFORMER-CURRENT (RATIO 300:5) | ||
| 5N-5432 | [3] | TRANSFORMER-CURRENT (RATIO 400:5) | ||
| 5N-5433 | [3] | TRANSFORMER-CURRENT (RATIO 600:5) | ||
| 6I-1952 | [3] | TRANSFORMER (RATIO 600:5) | ||
| 7E-1112 | [3] | TRANSFORMER (RATIO 800:5) | ||
| 7E-1113 | [3] | TRANSFORMER (RATIO 1000:5) | ||
| 7E-1114 | [3] | TRANSFORMER (RATIO 1200:5) | ||
| 7E-1115 | [3] | TRANSFORMER (RATIO 1500:5) | ||
| 7E-1116 | [3] | TRANSFORMER (RATIO 2000:5) | ||
| 7E-1117 | [3] | TRANSFORMER (RATIO 2500:5) | ||
| 7E-1118 | [3] | TRANSFORMER (RATIO 3000:5) | ||
| 7E-1119 | [3] | TRANSFORMER (RATIO 4000:5) | ||
| 5N-5430 | [3] | TRANSFORMER-CURRENT (RATIO 200:5) | ||
| 4B-4274 | [4] | WASHER (5.5X13X1.2-MM THK) | ||
| 5L-5180 | [4] | WASHER (0.49X0.875X0.05-IN THK) | ||
| 5L-5840 | [2] | WASHER (9.25X16.92X1.83-MM THK) | ||
| B | USE AS REQUIRED | |||
| D | ORDER BY THE METER | |||
| M | METRIC PART | |||
| Y | SEPARATE ILLUSTRATION | |||
#SEBP21961012
7W-0700: PANEL AR-CONTROL
7W-0700 PANEL AR-CONTROL
S/N 5AA4699-UP; 5CA5985-UP; 6RA1572-UP; 6ZA779-UP; 9AB1945-UP
GENERATOR MOUNTED
FOR USAGE REFER TO CHART @@@@@ 4W-8000@@@@@
AN ATTACHMENT
S/N 5AA4699-UP; 5CA5985-UP; 6RA1572-UP; 6ZA779-UP; 9AB1945-UP
GENERATOR MOUNTED
FOR USAGE REFER TO CHART @@@@@ 4W-8000@@@@@
AN ATTACHMENT
Parts for your 3304 GEN SET ENGINE:
CATERPILLAR SIS| Pos. | Part No | Qty | Parts name | Comments |
|---|---|---|---|---|
| 4W-8005 Y | [1] | CONTROL GP-AUTO START/STOP | ||
| 4W-8004 Y | [1] | CONTROL GP-MANUAL START/STOP | ||
| 4W-9904 Y | [1] | DOOR GP-ACCESS (DUSTPROOF) | ||
| 7W-0202 Y | [1] | DOOR GP-ACCESS (DUSTPROOF) | ||
| 4W-0483 Y | [1] | GAUGE GP-COOLANT TEMPERATURE (24-VOLT) | ||
| 4P-2788 Y | [1] | GOVERNOR AS-ELECTRONIC | ||
| 7E-1232 Y | [1] | GOVERNOR AS-ELECTRONIC | ||
| 7E-1233 Y | [1] | GOVERNOR AS-ELECTRONIC | ||
| 4W-8180 Y | [1] | GOVERNOR GP-ELECTRONIC | ||
| 4W-8185 Y | [1] | GOVERNOR GP-ELECTRONIC | ||
| 4W-8183 Y | [1] | LAMP GP-PANEL ILLUMINATION | ||
| 4W-8184 Y | [1] | METER GP-VOLT | ||
| 4W-8006 Y | [1] | MODULE GP-ALARM | ||
| 7C-3084 Y | [1] | MODULE GP-ALARM | ||
| 4W-8009 Y | [1] | MODULE GP-AUXILIARY RELAY | ||
| 4W-8007 Y | [1] | MODULE GP-CYCLE CRANKING | ||
| 4W-8002 Y | [1] | MODULE GP-SYNCHRONIZING LIGHTS | ||
| 4W-8003 Y | [1] | MODULE GP-SYNCHRONIZING LIGHTS | ||
| 7C-3262 Y | [1] | MODULE GP-SYNCHRONIZING LIGHTS | ||
| 7C-3263 Y | [1] | MODULE GP-SYNCHRONIZING LIGHTS | ||
| 4W-8008 Y | [1] | MODULE GP-TIMER | ||
| 4W-8181 Y | [1] | SWITCH GP-GOVERNOR | ||
| 4W-8182 Y | [1] | SWITCH GP-GOVERNOR | ||
| 4W-8102 Y | [3] | TRANSFORMER-CURRENT (RATIO 150:5) | ||
| 5N-5429 Y | [3] | TRANSFORMER-CURRENT (RATIO 100:5) | ||
| 5N-5430 Y | [3] | TRANSFORMER-CURRENT (RATIO 200:5) | ||
| 5N-5431 Y | [3] | TRANSFORMER-CURRENT (RATIO 300:5) | ||
| 5N-5432 Y | [3] | TRANSFORMER-CURRENT (RATIO 400:5) | ||
| 5N-5433 Y | [3] | TRANSFORMER-CURRENT (RATIO 600:5) | ||
| Y | SEPARATE ILLUSTRATION | |||
#SEBP21961013
7W-2411: PANEL AR-CONTROL
Parts for your 3304 GEN SET ENGINE:
CATERPILLAR SIS| Pos. | Part No | Qty | Parts name | Comments |
|---|---|---|---|---|
| 5N-5451 Y | [1] | ALARM GP (BASIC 24 VDC) | ||
| 5N-5452 Y | [1] | ALARM GP (BASIC 30-32 VDC) | ||
| 275-7792 Y | [1] | CIRCUIT BREAKER GP (225-AMPERE)(225 AMP WITH SHUNT TRIP) | ||
| 7W-8942 Y | [1] | CONTROL GP-AUTO START/STOP | ||
| 7W-8943 Y | [1] | CONTROL GP-AUTO START/STOP | ||
| 7W-8944 Y | [1] | CONTROL GP-MANUAL START/STOP | ||
| 7W-8945 Y | [1] | CONTROL GP-MANUAL START/STOP | ||
| 7W-8946 Y | [1] | CONTROL GP-MANUAL START/STOP | ||
| 7W-8947 Y | [1] | CONTROL GP-MANUAL START/STOP | ||
| 4W-9313 Y | [1] | GOVERNOR AS-ELECTRONIC | ||
| 4W-9314 Y | [1] | GOVERNOR AS-ELECTRONIC | ||
| 7W-9023 Y | [1] | MODULE GP-ALARM (STAND BY) | ||
| 7W-9024 Y | [1] | MODULE GP-ALARM (PRIME) | ||
| 4W-9311 Y | [1] | MODULE GP-SYNCHRONIZING LIGHTS | ||
| 4W-9312 Y | [1] | MODULE GP-SYNCHRONIZING LIGHTS | ||
| 7W-3372 Y | [1] | MODULE GP-SYNCHRONIZING LIGHTS | ||
| 4W-8632 | [1] | AMMETER AS (0 TO 100-AMPERE) | ||
| 4W-8633 | [1] | AMMETER AS (0 TO 150-AMPERE) | ||
| 4W-8634 | [1] | AMMETER AS (0 TO 200-AMPERE) | ||
| 4W-8635 | [1] | AMMETER AS (0 TO 300-AMPERE) | ||
| 4W-8636 | [1] | AMMETER AS (0 TO 400-AMPERE) | ||
| 4W-8637 | [1] | AMMETER AS (0 TO 600-AMPERE) | ||
| 4W-8638 | [1] | AMMETER AS (0 TO 800-AMPERE) | ||
| 4W-8639 | [1] | AMMETER AS (0 TO 1000-AMPERE) | ||
| 4W-8640 | [1] | AMMETER AS (0 TO 1200-AMPERE) | ||
| 4W-8641 | [1] | AMMETER AS (0 TO 1500-AMPERE) | ||
| 4W-9302 | [1] | CIRCUIT BREAKER AS (600-AMPERE) | ||
| 4W-9303 | [1] | CIRCUIT BREAKER AS (800-AMPERE) | ||
| 4W-9304 | [1] | CIRCUIT BREAKER AS (1200-AMPERE) | ||
| 4W-9612 | [1] | CIRCUIT BREAKER AS (60-AMPERE) | ||
| 4W-9613 | [1] | CIRCUIT BREAKER AS (70-AMPERE) | ||
| 4W-9614 | [1] | CIRCUIT BREAKER AS (80-AMPERE) | ||
| 4W-9615 | [1] | CIRCUIT BREAKER AS (90-AMPERE) | ||
| 4W-9616 | [1] | CIRCUIT BREAKER AS (100-AMPERE) | ||
| 4W-9617 | [1] | CIRCUIT BREAKER AS (125-AMPERE) | ||
| 4W-9618 | [1] | CIRCUIT BREAKER AS (150-AMPERE) | ||
| 5N-3350 | [1] | CIRCUIT BREAKER AS (250-AMPERE) | ||
| 7W-2318 | [1] | CIRCUIT BREAKER AS (400-AMPERE) | ||
| 5N-3352 | [1] | CIRCUIT BREAKER AS (200-AMPERE) | ||
| 5N-3353 | [1] | CIRCUIT BREAKER AS (175-AMPERE) | ||
| 7C-4471 | [1] | POTENTIOMETER AS (10,000-OHM)(VOLTAGE ADJUST) | ||
| 3N-5714 | [1] | RELAY AS (24-VOLT) | ||
| 7N-8008 | [1] | SWITCH AS-TOGGLE (GOVERNOR) | ||
| 3L-8187 | [6] | LOCKWASHER | ||
| 6T-3631 | [2] | NUT-HEX (15/32-32-THD) | ||
| 6T-3632 | [1] | LOCKWASHER | ||
| 6T-3633 | [1] | RING-LOCKING | ||
| 6V-8374 | [6] | SCREW-MACHINE (6-32X0.25-IN) | ||
| 8D-2676 | [1] | SWITCH AS-TOGGLE (SINGLE POLE)(ON/OFF CONTROL) | ||
| 3L-8187 | [2] | LOCKWASHER | ||
| 6T-3631 | [2] | NUT-HEX (15/32-32-THD) | ||
| 6T-3632 | [1] | LOCKWASHER | ||
| 6T-3633 | [1] | RING-LOCKING | ||
| 6V-8374 | [2] | SCREW-MACHINE (6-32X0.25-IN) | ||
| 5N-5430 | [3] | TRANSFORMER-CURRENT (RATIO 200:5) | ||
| 3N-5977 | [1] | BLOCK-FUSE (30-AMPERE) | ||
| 8N-7864 | [1] | FILM-WARNING (ELECTRICAL SHOCK HAZARD)(ENGLISH,FRENCH,SPANISH) | ||
| [1] | FILM-WARNING (ELECTRICAL SHOCK HAZARD)(PORTUGUESE,ARABIC,GERMAN) | |||
| 7W-0482 | [3] | FUSE (2-AMPERE) | ||
| 3N-5982 | [1] | KNOB (RHEOSTAT VOLTAGE ADJUST) | ||
| 7W-9018 | [1] | FILM-IDENTIFICATION (TERMINAL MARKER) | ||
| 4W-8647 | [1] | METER-FREQUENCY (45-65 HZ) | ||
| 4W-8644 | [1] | METER-VOLT (0 TO 300-VOLT) | ||
| 4W-8645 | [1] | METER-VOLT (0 TO 600-VOLT) | ||
| 7W-6969 | [1] | METER-VOLT (0 TO 750-VOLT) | ||
| 4W-9315 | [1] | METER-WATT (200-VOLT) | ||
| 4W-9316 | [1] | METER-WATT (240-VOLT) | ||
| 4W-9317 | [1] | METER-WATT (300-VOLT) | ||
| 4W-9318 | [1] | METER-WATT (400-VOLT) | ||
| 4W-9319 | [1] | METER-WATT (480-VOLT) | ||
| 4W-9320 | [1] | METER-WATT (600-VOLT) | ||
| 298-5630 | [1] | PLATE-IDENTIFICATION (CAT) | ||
| 6L-7003 | [1] | POTENTIOMETER (LEVEL & GAIN) | ||
| 5N-5498 | [1] | RELAY (32-VOLT DC) | ||
| 3N-5981 | [1] | RHEOSTAT (VOLTAGE ADJUST) | ||
| 4W-5731 | [1] | RHEOSTAT (VOLTAGE ADJUST) | ||
| 4W-8787 | [1] | SOCKET-RELAY | ||
| 5N-5540 | [2] | STRIP-TERMINAL | ||
| 3N-5976 | [1] | SWITCH (PHASE SELECT) | ||
| (4 POSION AMMETER/VOLTMETER PHASE SELECTOR) | ||||
| 4W-8792 | [1] | TIMER-COOL DOWN | ||
| 4W-8791 | [1] | TIMER-CYCLE | ||
| 3N-7817 | [1] | TRACK-MOUNTING | ||
| 4W-8102 | [3] | TRANSFORMER-CURRENT (RATIO 150:5) | ||
| 5N-5429 | [3] | TRANSFORMER-CURRENT (RATIO 100:5) | ||
| 5N-5431 | [3] | TRANSFORMER-CURRENT (RATIO 300:5) | ||
| 5N-5432 | [3] | TRANSFORMER-CURRENT (RATIO 400:5) | ||
| 5N-5433 | [3] | TRANSFORMER-CURRENT (RATIO 600:5) | ||
| 5N-5434 | [3] | TRANSFORMER-CURRENT (RATIO 800:5) | ||
| 7W-8839 | [3] | TRANSFORMER-CURRENT (RATIO 1000:5) | ||
| 7W-8838 | [3] | TRANSFORMER-CURRENT (RATIO 1200:5) | ||
| 7W-8837 | [3] | TRANSFORMER-CURRENT (RATIO 1500:5) | ||
| Y | SEPARATE ILLUSTRATION | |||
#SEBP21961014
7W-3401: PANEL AR-CONTROL
7W-3401 PANEL AR-CONTROL
S/N 83Z3096-UP
FOR USAGE REFER TO CHART @@@@@ 7W-3400@@@@@
AN ATTACHMENT
S/N 83Z3096-UP
FOR USAGE REFER TO CHART @@@@@ 7W-3400@@@@@
AN ATTACHMENT
Parts for your 3304 GEN SET ENGINE:
CATERPILLAR SIS| Pos. | Part No | Qty | Parts name | Comments |
|---|---|---|---|---|
| 4W-5391 Y | [1] | BOX AS-GOVERNOR PREREGULATOR | ||
| 2W-8683 | [1] | BLOCK-CONTACT | ||
| 4W-8790 | [1] | BLOCK-FUSE | ||
| 4W-8734 | [1] | BOARD AS-FAULT (24 VOLT) | ||
| 3N-5719 | [4] | LAMP (24-VOLT) | ||
| 4W-8745 | [4] | HOUSING AS-LAMP | ||
| 4W-8746 | [4] | LENS-LAMP (RED) | ||
| 7W-3403 | [1] | BOARD AS-FAULT (32 VOLT) | ||
| 3N-5719 | [4] | LAMP (24-VOLT) | ||
| 4W-8745 | [4] | HOUSING AS-LAMP | ||
| 4W-8746 | [4] | LENS-LAMP (RED) | ||
| 131-5453 | [1] | CONTROL AS-ELECTRONIC GOVERNOR | ||
| 2W-4899 | [1] | DIODE AS | ||
| 7W-3069 | [1] | FILM-CONTROL PANEL (ENGLISH) | ||
| 7W-3070 | [1] | FILM-CONTROL PANEL (FRENCH) | ||
| 7W-3071 | [1] | FILM-CONTROL PANEL (SPANISH) | ||
| 7W-3072 | [1] | FILM-CONTROL PANEL (PORTUGUESE) | ||
| 7W-3073 | [1] | FILM-CONTROL PANEL (GERMAN) | ||
| 7W-3074 | [1] | FILM-CONTROL PANEL (ARABIC) | ||
| 7T-0037 | [2] | FUSE (0.75-AMPERE) | ||
| 4W-8226 | [1] | MARKER (TERMINAL) | ||
| 4W-8227 | [1] | MARKER (TERMINAL) | ||
| 5N-5498 | [4] | RELAY (32-VOLT DC) | ||
| 3N-5714 | [4] | RELAY AS (24-VOLT) | ||
| 4W-8787 | [4] | SOCKET-RELAY | ||
| 4W-8229 | [2] | STRIP-TERMINAL (20 POINT) | ||
| 3N-5976 | [1] | SWITCH (PHASE SELECT)(ENGINE CONTROL) | ||
| 4W-8735 | [1] | SWITCH-STOP (EMERGENCY) | ||
| 3N-5978 | [1] | TIMER AS-ON DELAY (ARMING) | ||
| 3N-5978 | [1] | TIMER AS-ON DELAY (OVERCRANK) | ||
| 4W-8792 | [1] | TIMER-COOL DOWN | ||
| 4W-8791 | [1] | TIMER-CYCLE (CRANK) | ||
| 7W-3645 | [1] | TRACK-MOUNTING (TIMER) | ||
| 3N-7817 | [2] | TRACK-MOUNTING (TIMER MTG) | ||
| Y | SEPARATE ILLUSTRATION | |||
#SEBP21961015
3N-7325: PANEL GP-ANNUNCIATOR
Parts for your 3304 GEN SET ENGINE:
CATERPILLAR SIS| Pos. | Part No | Qty | Parts name | Comments |
|---|---|---|---|---|
| 1. | 3N-7782 | [13] | LAMP (6-28 VOLTS)(RED) | |
| (FOUR LAMPS AFFIXED TO PANEL FOR SPARE) | ||||
#SEBP21961016
121-4712: PANEL GP-ELECTRONIC
121-4712 PANEL GP-ELECTRONIC
S/N 83Z3096-UP
FOR USE WITH PANEL LIGHTS AND AUXILIARY RELAY ON EMCPII
AN ATTACHMENT
S/N 83Z3096-UP
FOR USE WITH PANEL LIGHTS AND AUXILIARY RELAY ON EMCPII
AN ATTACHMENT
Parts for your 3304 GEN SET ENGINE:
CATERPILLAR SIS| Pos. | Part No | Qty | Parts name | Comments |
|---|---|---|---|---|
| 128-3326 Y | [1] | RELAY GP (24-VOLT)(AUXILIARY) | ||
| 7G-9730 | [2] | LAMP AS (120-VOLT, 3-WATT)(CLEAR) | ||
| (EACH INCLUDES) | ||||
| 6V-8367 | [1] | LOCKWASHER | ||
| 6V-8382 | [1] | NUT-HEX (11/16-27-THD) | ||
| 8D-2676 | [1] | SWITCH AS-TOGGLE (SINGLE POLE)(PANEL LIGHT) | ||
| 3L-8187 | [2] | LOCKWASHER | ||
| 6T-3631 | [2] | NUT-HEX (15/32-32-THD) | ||
| 6T-3632 | [1] | LOCKWASHER | ||
| 6T-3633 | [1] | RING-LOCKING | ||
| 6V-8374 | [2] | SCREW-MACHINE (6-32X0.25-IN) | ||
| 9X-9675 | [2] | BRACKET-END | ||
| 7N-5876 | [3] | LAMP (24-VOLT, 0.2-AMPERE)(CLEAR) | ||
| 5H-6555 | [2] | LOCKWASHER | ||
| 097-5921 | [1] | RAIL-MOUNTING | ||
| 9X-6258 | [2] | SCREW-MACHINE (6-32X0.5-IN) | ||
| 4B-5324 | [2] | WASHER (3.9X9.6X1.2-MM THK) | ||
| Y | SEPARATE ILLUSTRATION | |||
#SEBP21961017
5N-4261: PANEL GP-ELECTRONIC
5N-4261 PANEL GP-ELECTRONIC
S/N 5AA4699-UP; 5CA5985-UP
BOOST SERIES
AN ATTACHMENT
S/N 5AA4699-UP; 5CA5985-UP
BOOST SERIES
AN ATTACHMENT
Parts for your 3304 GEN SET ENGINE:
CATERPILLAR SIS#SEBP21961018
131-1960: PANEL GP-INSTRUMENT
131-1960 PANEL GP-INSTRUMENT
S/N 9AB1945-UP
REMOTE ANNUNCIATOR
FOR USE WITH GENERATOR SET CONTROL PANEL
AN ATTACHMENT
S/N 9AB1945-UP
REMOTE ANNUNCIATOR
FOR USE WITH GENERATOR SET CONTROL PANEL
AN ATTACHMENT
Parts for your 3304 GEN SET ENGINE:
CATERPILLAR SIS#SEBP21961019
131-1961: PANEL GP-INSTRUMENT
131-1961 PANEL GP-INSTRUMENT
S/N 9AB1945-UP
REMOTE ANNUNCIATOR
FOR USE WITH EMCP II
AN ATTACHMENT
S/N 9AB1945-UP
REMOTE ANNUNCIATOR
FOR USE WITH EMCP II
AN ATTACHMENT
Information:
OPERATOR STATION
PANEL GP
Engine News
Product Support Literature Available For Electronic Modular Control Panels Used On SR4 Generators
1988/02/01
1988/02/01
Different Emergency Stop Push Buttons for Electronic Modular Control Panel II (EMCP II) {4490,4450}
1994/09/01
1994/09/01
New CAT Inspect Form Available for EMCP Troubleshooting and Inspection {0374, 4490, 7451, 7620}
New CAT Inspect Form Available for EMCP Troubleshooting and Inspection {0374, 4490, 7451, 7620}
New CAT Inspect Form Available for EMCP Troubleshooting and Inspection {0374, 4490, 7451, 7620}
Special Instruction
Removal Of 4P-6407 Film From The Generator Set Control (GSC) Of The Electronic Modular Control Panel II (EMCP II){4490, 7451}
Removal Of 4P-6407 Film From The Generator Set Control (GSC) Of The Electronic Modular Control Panel II (EMCP II){4490, 7451}
Removal Of 4P-6407 Film From The Generator Set Control (GSC) Of The Electronic Modular Control Panel II (EMCP II){4490, 7451}
EMCP 3 to EMCP 4.1/4.2 Cat <SUP>®</SUP> Retrofit Instructions{4490}
EMCP 3 to EMCP 4.1/4.2 Cat ® Retrofit Instructions{4490}
EMCP 3 to EMCP 4.1/4.2 Cat ® Retrofit Instructions{4490}
Procedure to Upgrade EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.3{4490}
Procedure to Upgrade EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.3{4490}
Procedure to Upgrade EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.3{4490}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.4 {4490}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.4 {4490}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.4 {4490}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.2 {4490, 7451}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.2 {4490, 7451}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.2 {4490, 7451}
Instructions for Installing AssetIQ<SUP>TM</SUP> for Commercial Generator Set Systems on Caterpillar and non-Caterpillar Products {4450, 7490}
Instructions for Installing AssetIQTM for Commercial Generator Set Systems on Caterpillar and non-Caterpillar Products {4450, 7490}
Instructions for Installing AssetIQTM for Commercial Generator Set Systems on Caterpillar and non-Caterpillar Products {4450, 7490}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.2 {4490, 7610}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.2 {4490, 7610}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.2 {4490, 7610}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.2B {1408, 4490, 7418, 7426, 7451}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.2B {1408, 4490, 7418, 7426, 7451}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.2B {1408, 4490, 7418, 7426, 7451}
Systems Operation
Service Magazine
Caterpillar Parts SIS Catalog 3304 :
Truck sale:
650
Caterpillar 303/304 ADAPTER SSL TO MHE, Schnellwechsler, Bau-Und Bergbauausrüstung
- Quick connectors
MILTON CAT
- Quick connectors
MILTON CAT
17.000
Caterpillar 3304, Stationäre Stromaggregate, Bau-Und Bergbauausrüstung
- Stationary Generator Sets
EMPIRE MACHINERY
- Stationary Generator Sets
EMPIRE MACHINERY