290-5565 HEAT SINK AS S/N 5NJ1-UP; 6EJ1-UP; 7AJ2261-UP; 1MS1-UP PART OF 130-0234, 9Y-0386, 9Y-0400 GENERATOR GP ALSO FIELD INSTALLATION 3412





GENERATORS

GENERATOR GP
 

#SEBP22680960
 

290-5565: HEAT SINK AS

290-5565 HEAT SINK AS
S/N 5NJ1-UP; 6EJ1-UP; 7AJ2261-UP; 1MS1-UP
PART OF 130-0234, 9Y-0386, 9Y-0400 GENERATOR GP
ALSO FIELD INSTALLATION
i02583931 SEBP2268
  For full view, you need register

Parts for your 3412 GEN SET ENGINE:

Pos. Part No Qty Parts name Comments
    (NO SERVICED PARTS)
 

#SEBP22680961
 

4P-4488: HEAT SINK AS

4P-4488 HEAT SINK AS
S/N 5NJ1-UP; 6EJ1-UP; 7AJ1-UP; 1MS1-UP
PART OF 106-3578, 106-3579, 109-1595, 109-1596, 109-1597, 109-1598, 109-1599, 109-1600, 109-1601, 109-1602, 109-1603, 109-1604, 109-1605, 109-1606, 129-5034, 130-0235, 183-5788, 207-1785, 207-1786, 9Y-0385, 9Y-0386, 9Y-0392, 9Y-0393, 9Y-0400, 9Y-1430, 9Y-1431 GENERATOR GP
i00376340 SEBP2268
  For full view, you need register

Parts for your 3412 GEN SET ENGINE:

Pos. Part No Qty Parts name Comments
1. 9Y-0916 [1] RECTIFIER AS  
  4C-6715 [1] KIT-RECTIFIER SILICONE  
  7X-3362 B [2] BOLT (10-32X0.625-IN)  
  8H-4959 B [2] BOLT (10-32X0.875-IN)  
  117-8556 [2] WASHER (5.6X7.8X0.5-MM THK)  
2. 9Y-9412 [1] VARISTOR  
3. 8L-5832 [2] NUT-HEX (10-32-THD)  
4. 9F-7022 [2] BOLT (1/4-20X1.5-IN)  
5. 9S-8750 [2] NUT-FULL (1/4-20-THD)  
6. 5P-0537 [2] WASHER-HARD (7.2X14.5X2-MM THK)  
7. 4P-4608 [1] HEAT SINK  
8. 5N-3886 [2] SCREW (10-32X1.5-IN)  
9. 4B-4274 [2] WASHER (5.5X13X1.2-MM THK)  
  B   USE AS REQUIRED
 

#SEBP22680962
 

161-6012: HEATER AS-SPACE

161-6012 HEATER AS-SPACE
S/N 2WJ1-UP
FOR USE WITH POWER MODULES
AN ATTACHMENT
i00968593 SEBP2268
  For full view, you need register

Parts for your 3412 GEN SET ENGINE:

Pos. Part No Qty Parts name Comments
    (NO SERVICED PARTS)
 

#SEBP22680963
 

4P-1782: KIT-BUS BAR

4P-1782 KIT-BUS BAR
S/N 5NJ1-UP; 6EJ1-UP; 7AJ1-UP
PROVIDES CONNECTION POINT FOR POWER LEADS COMING OUT OF STATOR AS
PART OF 106-3578, 106-3579, 109-1595, 109-1596, 109-1597, 109-1598, 109-1599, 109-1600, 109-1601, 109-1602, 109-1603, 109-1604, 109-1605, 109-1606, 183-5788, 207-1785, 296-5201, 344-2719, 9Y-0385, 9Y-0386, 9Y-0392, 9Y-0393, 9Y-0400, 9Y-1430, 9Y-1431 GENERATOR GP
ALSO AN ATTACHMENT
i01155767 SEBP2268
  For full view, you need register

Parts for your 3412 GEN SET ENGINE:

Pos. Part No Qty Parts name Comments
1. 4P-4515 [1] BRACKET-BUS BAR  
2. 4P-4522 [1] SUPPORT  
3. 4P-4506 [1] INSULATOR  
4. 4P-4521 [3] BAR-BUS  
5. 4P-1778 [1] BAR-BUS  
6. 4P-8402 [4] BRACKET  
7. 8C-3121 [2] BOLT (5/16-18X1.5-IN)  
8. 4M-6425 [18] BOLT (5/16-18X1-IN)  
9. 8T-4224 [36] WASHER-HARD (8.8X16X2-MM THK)  
10. 6V-8189 [16] NUT (5/16-18-THD)  
11. 4L-9337 [6] BOLT (3/8-16X1.5-IN)  
12. 8T-4896 [12] WASHER-HARD (10.2X18.5X2.5-MM THK)  
13. 6V-8801 [6] NUT (3/8-16-THD)  
 

#SEBP22680964
 

4P-1799: KIT-BUS BAR

4P-1799 KIT-BUS BAR
S/N 5NJ1-UP; 7AJ500-UP; 1MS1-UP
PROVIDES DUAL VOLTAGE BUS BAR AS.
PART OF 129-5034, 130-0234, 130-0235, 207-1786, 342-0549, 344-2713 GENERATOR GP
ALSO AN ATTACHMENT
i01155928 SEBP2268
  For full view, you need register

Parts for your 3412 GEN SET ENGINE:

Pos. Part No Qty Parts name Comments
1. 4P-4515 [1] BRACKET-BUS BAR  
2. 4P-4522 [1] SUPPORT  
3. 126-2427 [1] BAR-BUS  
4. 4P-4521 [3] BAR-BUS  
5. 126-2428 [1] INSULATOR  
6. 4P-8402 [4] BRACKET  
7. 8T-2501 [6] BOLT (3/8-16X2-IN)  
8. 8T-4224 [36] WASHER-HARD (8.8X16X2-MM THK)  
9. 4M-6425 [18] BOLT (5/16-18X1-IN)  
10. 6V-8189 [16] NUT (5/16-18-THD)  
11. 4L-9337 [6] BOLT (3/8-16X1.5-IN)  
12. 8T-4896 [64] WASHER-HARD (10.2X18.5X2.5-MM THK)  
13. 6V-8801 [32] NUT (3/8-16-THD)  
14. 8C-3121 [2] BOLT (5/16-18X1.5-IN)  
15. 9B-7237 [14] BOLT (3/8-16X1.25-IN)  
 

#SEBP22680965
 

4P-1788: KIT-SPACE HEATER

4P-1788 KIT-SPACE HEATER -GENERATOR
S/N 5NJ1-UP; 6EJ1-UP; 7AJ1-UP; 1MS1-UP
PART OF 106-3579, 109-1597, 109-1600, 109-1603, 109-1606, 129-5034, 207-1785, 207-1786, 296-5201, 342-0549, 344-2713, 344-2719, 9Y-1430, 9Y-1431 GENERATOR GP
FOR USE WITH 590 SQUARE LAMINATION SR4B GENERATOR
ALSO AN ATTACHMENT
i00374201 SEBP2268
  For full view, you need register

Parts for your 3412 GEN SET ENGINE:

Pos. Part No Qty Parts name Comments
1. 8T-9043 [4] BOLT (5/16-18X0.875-IN)  
2. 4P-1801 [2] HEATER GP-SPACE (GENERATOR)  
3. 8L-8413 B [4] STRAP-CABLE (WHITE)  
4. 4D-6066 [1] STRIP-TERMINAL  
5. 3N-8763 [1] STRIP-TERMINAL  
6. 115-4598 [1] LEAD AS  
7. 6V-8548 [2] SCREW-WASHER HEAD (8-32X0.85-IN)  
8. 5P-4116 [4] WASHER-HARD (8.8X20.5X2-MM THK)  
  B   USE AS REQUIRED
 

#SEBP22680966
 

5N-2312: LIFTING GP-GENERATOR

5N-2312 LIFTING GP-GENERATOR
S/N 2WJ1-UP
FOR USE WITH ENCLOSURE BASE ONLY
AN ATTACHMENT
i00384630 SEBP2268
  For full view, you need register

Parts for your 3412 GEN SET ENGINE:

Pos. Part No Qty Parts name Comments
1. 5N-2313 [1] LIFTING AS  
2. 1D-4709 [16] BOLT (1-8X3-IN)  
  9B-1948 [16] SPACER (1.031X1.625X1-IN THK)  
 

#SEBP22680967
 

123-8591: MOUNTING GP-VOLTAGE REGULATOR

123-8591 MOUNTING GP-VOLTAGE REGULATOR
S/N 6EJ1-UP
PART OF 121-6200 REGULATOR GP-VOLTAGE
AN ATTACHMENT
i00515476 SEBP2268
  For full view, you need register

Parts for your 3412 GEN SET ENGINE:

Pos. Part No Qty Parts name Comments
1. 4B-4674 [1] WASHER (6.4X14.5X1.6-MM THK)  
2. 7C-5708 [3] GROMMET  
3. 7C-5709 [3] SLEEVE  
4. 246-8826 [6] WASHER-HARD (7.2X32X1-MM THK)  
5. 5P-0537 [6] WASHER-HARD (7.2X14.5X2-MM THK)  
6. 6V-8185 [4] NUT (1/4-20-THD)  
7. 8J-1256 [1] CLIP (LOOP)  
8. 4L-3776 [4] BOLT (1/4-20X4.75-IN)  
 

#SEBP22680968
 

124-1563: MOUNTING GP-VOLTAGE REGULATOR

124-1563 MOUNTING GP-VOLTAGE REGULATOR
S/N 5NJ1-UP; 6EJ1-UP; 7AJ1-UP; 1MS1-UP
PART OF 121-6202 REGULATOR GP-VOLTAGE
AN ATTACHMENT
i00516309 SEBP2268
  For full view, you need register

Parts for your 3412 GEN SET ENGINE:

Pos. Part No Qty Parts name Comments
1. 4B-2043 [1] NUT (8-32-THD)  
2. 4B-4674 [1] WASHER (6.4X14.5X1.6-MM THK)  
3. 7C-5708 [3] GROMMET  
4. 7C-5709 [3] SLEEVE  
5. 9B-7233 [1] LOCKWASHER  
6. 033-2075 [6] WASHER (0.266X1.25X0.06-IN THK)  
7. 5P-0537 [6] WASHER-HARD (7.2X14.5X2-MM THK)  
8. 6V-8185 [4] NUT (1/4-20-THD)  
9. 8J-1256 [1] CLIP (LOOP)  
 

#SEBP22680969
 

130-3481: MOUNTING GP-VOLTAGE REGULATOR

130-3481 MOUNTING GP-VOLTAGE REGULATOR
S/N 5NJ1-UP; 6EJ1-UP; 7AJ1-UP; 1MS1-UP
FOR USE WITH 590 FRAME GENERATOR WITH VR3, VR3F, AND DIGITAL VOLTAGE REGULATOR
AN ATTACHMENT
i00501457 SEBP2268
  For full view, you need register

Parts for your 3412 GEN SET ENGINE:

Pos. Part No Qty Parts name Comments
1. 9S-8750 [4] NUT-FULL (1/4-20-THD)  
2. 7C-5708 [3] GROMMET  
3. 7C-5709 [3] SLEEVE  
4. 246-8826 [6] WASHER-HARD (7.2X32X1-MM THK)  
5. 5P-0537 [7] WASHER-HARD (7.2X14.5X2-MM THK)  
6. 9B-7233 [1] LOCKWASHER  
7. 4B-2043 [1] NUT (8-32-THD)  
8. 8J-1256 [1] CLIP (LOOP)  
9. 3S-2093 B [6] STRAP-CABLE  
  B   USE AS REQUIRED
 

Information:

General Service Information
Safety
SR4 GENERATOR MOUNTED CONTROL PANEL FOR SPARK IGNITED (SI) E
Identification
SR4 GENERATOR MOUNTED CONTROL PANEL FOR SPARK IGNITED (SI) E
Abbreviations
SR4 GENERATOR MOUNTED CONTROL PANEL FOR SPARK IGNITED (SI) E
Symbols
SR4 GENERATOR MOUNTED CONTROL PANEL FOR SPARK IGNITED (SI) E
Components
SR4 GENERATOR MOUNTED CONTROL PANEL FOR SPARK IGNITED (SI) E
Energize To Run Engine System
SR4 GENERATOR MOUNTED CONTROL PANEL FOR SPARK IGNITED (SI) E
Schematics And Wiring Diagrams
SR4 GENERATOR MOUNTED CONTROL PANEL FOR SPARK IGNITED (SI) E
Operation
FLOOR-STANDING SWITCHGEAR
Automatic Start-Stop
FLOOR-STANDING SWITCHGEAR
Automatic Start-Stop Troubleshooting
FLOOR-STANDING SWITCHGEAR
Engine News
Special Instruction
Generator Service Literature Index{4450}
Generator Service Literature Index{4450}
Grounding Design Guide for Electric Power Generation Products {4450, 4459}
Grounding Design Guide for Electric Power Generation Products {4450, 4459}
Generator Bearing Service {4457}
Generator Bearing Service {4457}
Instructions for Installing AssetIQ<SUP>TM</SUP> for Commercial Generator Set Systems on Caterpillar and non-Caterpillar Products {4450, 7490}
Instructions for Installing AssetIQTM for Commercial Generator Set Systems on Caterpillar and non-Caterpillar Products {4450, 7490}
Technical Information Bulletin
Generator Lead Connections Can Rub Against The Terminal Box Or Each Other
Generator Lead Connections Can Rub Against The Terminal Box Or Each Other
Paralleling Generators To Utility Substations
Paralleling Generators To Utility Substations
Application of Thermally Conductive 4C-6715 Rectifier Silicone Kit when Installing 9Y-0916 Rectifier Assembly
Application of Thermally Conductive 4C-6715 Rectifier Silicone Kit when Installing 9Y-0916 Rectifier Assembly
Specifications
General Information
SR4 and SR4B Electric Power Generation Rewind Data
Generator Identification
SR4 and SR4B Electric Power Generation Rewind Data
Component Views
SR4 and SR4B Electric Power Generation Rewind Data
Connection Diagrams for Exciter
SR4 and SR4B Electric Power Generation Rewind Data
Connection Diagrams for Main Stator and Main Rotor
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for <B>5N-0001</B> Generator through <B>5N-0025</B> Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for <B>5N-0027</B> Generator through <B>5N-0050</B> Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for <B>5N-0051</B> Generator through <B>5N-0075</B> Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for <B>5N-0076</B> Generator through <B>5N-0090</B> Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for <B>5N-0431</B> Generator through <B>5N-7207</B> Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for <B>5N-7208</B> Generator through <B>5N-7232</B> Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for <B>5N-7233</B> Generator through <B>5N-7309</B> Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for <B>5N-8891</B> Generator through <B>5N-8911</B> Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for <B>5N-9081</B> Generator through <B>5N-9432</B> Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for <B>4P-2236</B> Generator through <B>4P-9907</B> Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for <B>4W-0183</B> Generator through <B>4W-9669</B> Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for <B>7C-1601</B> Generator through <B>7C-9126</B> Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for <B>7E-0097</B> Generator through <B>7E-9695</B> Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for <B>7W-1877</B> Generator through <B>7W-8825</B> Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for <B>9Y-0157</B> Generator through <B>9Y-0389</B> Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for <B>9Y-0390</B> Generator through <B>9Y-0533</B> Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for <B>9Y-1408</B> Generator through <B>9Y-9422</B> Generator
SR4 and SR4B Electric Power Generation Rewind Data
Terminology
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for 144-0469 Generator through 144-0583 Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for 166-2651 Generator through 166-2689 Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for 166-2691 Generator through 166-7187 Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for 144-1811 Generator through 144-1951 Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for 147-9437 Generator through 147-9497 Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for 153-3081 Generator through 153-3098 Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for 167-1351 Generator through 167-1354 Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for 126-8022 Generator through 128-7424 Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for 136-6580 Generator through 136-6609 Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for 141-5534 Generator through 142-9900 Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for 144-1666 Generator through 144-1766 Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for 136-6610 Generator through 136-6641 Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for 144-1964 Generator through 144-2088 Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for 149-2447 Generator through 150-9152 Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for 158-6410 Generator through 163-8546 Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for 164-0975 Generator through 164-4946 Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for 173-7078 Generator through 194-6563 Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for 203-5749 Generator through 324-5120 Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for 6I-0053 Generator through 6I-4860 Generator
SR4 and SR4B Electric Power Generation Rewind Data
Winding Data for 109-3776 Generator through 109-7874 Generator
SR4 and SR4B Electric Power Generation Rewind Data
Systems Operation
Generator Operation
SR4B Generators
General Information
SR4B Generators
Component Descriptions
SR4B Generators
Glossary
SR4B Generators
Main Revolving Field Connections (All Except SR4B for 3500 Engines)
Connection Diagrams: SR4 and SR4B Generators, Voltage Regulators, Options
Options (All Except SR4B for 3500 Engines)
Connection Diagrams: SR4 and SR4B Generators, Voltage Regulators, Options
Main Revolving Field Connections (SR4B for 3500 Engines)
Connection Diagrams: SR4 and SR4B Generators, Voltage Regulators, Options
Options (SR4B for 3500 Engines)
Connection Diagrams: SR4 and SR4B Generators, Voltage Regulators, Options
General Information (All Except SR4B for 3500 Engines)
Connection Diagrams: SR4 and SR4B Generators, Voltage Regulators, Options
General Information (SR4B for 3500 Engines)
Connection Diagrams: SR4 and SR4B Generators, Voltage Regulators, Options
Generator Wiring Diagrams (SR4B for 3500 Engines)
Connection Diagrams: SR4 and SR4B Generators, Voltage Regulators, Options
Main Stator and Voltage Sensing Lead Connections (All Except SR4B for 3500 Engines)
Connection Diagrams: SR4 and SR4B Generators, Voltage Regulators, Options
Main Stator and Voltage Sensing Lead Connections (SR4B for 3500 Engines)
Connection Diagrams: SR4 and SR4B Generators, Voltage Regulators, Options
Oil Field Generator Connections (SR4)
Connection Diagrams: SR4 and SR4B Generators, Voltage Regulators, Options
Testing and Adjusting
General Information
SR4B Generators
Troubleshooting
SR4B Generators
Generator Set - Test
SR4B Generators
Varistor - Test
SR4B Generators
Winding - Test
SR4B Generators
Resistor - Test
SR4B Generators
Exciter Field - Flash
SR4B Generators
Generator - Dry
SR4B Generators
Insulation - Test
SR4B Generators
Disassembly and Assembly
Coupling - Install
SR4B Generators
Coupling - Remove
SR4B Generators
Generator - Align
SR4B Generators
Generator - Install
SR4B Generators
Generator - Remove
SR4B Generators
Service Magazine

Caterpillar Parts SIS Catalog 3412 :

Truck sale:

95,720 
Caterpillar 3412, mobile generator sets, Construction
- mobile generator sets
FINANZAUTO S.A.
96,795 
Caterpillar 3412, mobile generator sets, Construction
- mobile generator sets
FINANZAUTO S.A.
93,569 
Caterpillar 3412, mobile generator sets, Construction
- mobile generator sets
FINANZAUTO S.A.
60,000 
Caterpillar 3412, Stationary Generator Sets, Construction
- Stationary Generator Sets
FOLEY EQUIPMENT COMPANY
159,600 
Caterpillar 3412, Stationary Generator Sets, Construction
- Stationary Generator Sets
FOLEY EQUIPMENT COMPANY