OPERATOR STATION
PANEL GPOPERATOR STATION
PANEL GP#SEBP40400160
243-3791: PANEL GP-ELECTRICAL
243-3791 PANEL GP-ELECTRICAL
SYSTEM CONTROLLER
PART OF 244-4501 PANEL GP-POWER SUPPLY
ALSO AN ATTACHMENT
SYSTEM CONTROLLER
PART OF 244-4501 PANEL GP-POWER SUPPLY
ALSO AN ATTACHMENT
Parts for your ES12F UNINTERRUPTIBLE PWR SU:
CATERPILLAR SISPos. | Part No | Qty | Parts name | Comments |
---|---|---|---|---|
300. | 239-9266 Y | [1] | BOARD AS-CIRCUIT (SYSTEM CONTROLLER) | |
(PARTS SHOWN ON THE GRAPHIC WITHOUT CATERPILLAR PART NUMBERS CAN BE PROCURED | ||||
FROM LOCAL PARTS DISTRIBUTORS BY THE DESCRIPTIONS SHOWN.) | ||||
Y | SEPARATE ILLUSTRATION |
#SEBP40400161
243-3793: PANEL GP-ELECTRICAL
243-3793 PANEL GP-ELECTRICAL
DISCONNECT SWITCH
PART OF 244-4501 PANEL GP-POWER SUPPLY
ALSO AN ATTACHMENT
DISCONNECT SWITCH
PART OF 244-4501 PANEL GP-POWER SUPPLY
ALSO AN ATTACHMENT
Parts for your ES12F UNINTERRUPTIBLE PWR SU:
CATERPILLAR SISPos. | Part No | Qty | Parts name | Comments |
---|---|---|---|---|
100. | 240-1918 | [1] | PANEL | |
200. | 240-1907 | [1] | HANDLE | |
201. | 240-2733 | [1] | LIGHT (RED) | |
202. | 240-2734 | [1] | LIGHT (GREEN) | |
203. | 240-2729 | [1] | SWITCH-PUSH BUTTON (FLYWHEEL READY STATUS) | |
PARTS SHOWN ON THE GRAPHIC WITHOUT CATERPILLAR PART NUMBERS CAN BE PROCURED FROM LOCAL PARTS DISTRIBUTORS BY THE DESCRIPTIONS SHOWN |
#SEBP40400162
243-3795: PANEL GP-ELECTRICAL
243-3795 PANEL GP-ELECTRICAL
DC INTERFACE
PART OF 244-4501 PANEL GP-POWER SUPPLY
ALSO AN ATTACHMENT
DC INTERFACE
PART OF 244-4501 PANEL GP-POWER SUPPLY
ALSO AN ATTACHMENT
Parts for your ES12F UNINTERRUPTIBLE PWR SU:
CATERPILLAR SIS#SEBP40400163
244-4504: PANEL GP-ELECTRICAL
244-4504 PANEL GP-ELECTRICAL
CONVERTER MODULE
PART OF 244-4501 PANEL GP-POWER SUPPLY
ALSO AN ATTACHMENT
CONVERTER MODULE
PART OF 244-4501 PANEL GP-POWER SUPPLY
ALSO AN ATTACHMENT
Parts for your ES12F UNINTERRUPTIBLE PWR SU:
CATERPILLAR SIS#SEBP40400164
244-4980: PANEL GP-ELECTRICAL
244-4980 PANEL GP-ELECTRICAL
S/N CZS1-UP; CZT1-UP
USER INTERFACE
PART OF 244-4979 ENCLOSURE GP-POWER SUPPLY
S/N CZS1-UP; CZT1-UP
USER INTERFACE
PART OF 244-4979 ENCLOSURE GP-POWER SUPPLY
Parts for your ES12F UNINTERRUPTIBLE PWR SU:
CATERPILLAR SISPos. | Part No | Qty | Parts name | Comments |
---|---|---|---|---|
200. | 240-1699 | [1] | DISPLAY | |
201. | 201-2631 | [1] | SWITCH-PUSH BUTTON (EMERGENCY STOP) | |
202. | 240-2683 | [1] | GUARD (SWITCH, RECTANGULAR) | |
204. | 227-4840 | [1] | COVER | |
300. | 279-6658 Y | [1] | BOARD AS-CIRCUIT (DISPLAY INTERFACE) | |
301. | 240-2547 | [1] | MODULE (MASTER) | |
302. | 267-9384 | [1] | BOARD AS (BACKLIGHT) | |
705. | 256-7182 | [4] | FASTENER | |
900. | 240-2552 | [1] | PANEL-DISPLAY (DISPLAY) | |
PARTS SHOWN ON THE GRAPHIC WITHOUT CATERPILLAR PART NUMBERS CAN BE PROCURED FROM LOCAL PARTS DISTRIBUTORS BY THE DESCRIPTIONS SHOWN | ||||
Y | SEPARATE ILLUSTRATION |
#SEBP40400165
244-4983: PANEL GP-ELECTRICAL
244-4983 PANEL GP-ELECTRICAL
S/N CZS1-UP; CZT1-UP
CONTROL, RH
PART OF 244-4982 ENCLOSURE GP-POWER SUPPLY
S/N CZS1-UP; CZT1-UP
CONTROL, RH
PART OF 244-4982 ENCLOSURE GP-POWER SUPPLY
Parts for your ES12F UNINTERRUPTIBLE PWR SU:
CATERPILLAR SISPos. | Part No | Qty | Parts name | Comments |
---|---|---|---|---|
200. | 240-2707 | [6] | TRANSFORMER AS | |
202. | 240-2509 | [1] | BLOCK-TERMINAL (4-POLE) | |
300. | 242-9379 | [1] | BOARD AS-CIRCUIT (HIGH VOLTAGE INTERFACE) | |
301. | 239-9264 Y | [1] | BOARD AS-CIRCUIT (SYSTEM CONTROLLER TWO) | |
302. | 242-9374 Y | [1] | BOARD AS-CIRCUIT (DUAL NETWORK INTERFACE) | |
(PARTS SHOWN ON THE GRAPHIC WITHOUT CATERPILLAR PART NUMBERS CAN BE PROCURED | ||||
FROM LOCAL PARTS DISTRIBUTORS BY THE DESCRIPTIONS SHOWN.) | ||||
Y | SEPARATE ILLUSTRATION |
#SEBP40400166
244-4984: PANEL GP-ELECTRICAL
244-4984 PANEL GP-ELECTRICAL
S/N CZS1-UP; CZT1-UP
CONTROL, REAR
PART OF 244-4982 ENCLOSURE GP-POWER SUPPLY, 294-3319 FRAME AS
S/N CZS1-UP; CZT1-UP
CONTROL, REAR
PART OF 244-4982 ENCLOSURE GP-POWER SUPPLY, 294-3319 FRAME AS
Parts for your ES12F UNINTERRUPTIBLE PWR SU:
CATERPILLAR SISPos. | Part No | Qty | Parts name | Comments |
---|---|---|---|---|
200. | 236-4172 | [1] | TRANSFORMER (3.34-AMPERE) | |
201. | 240-2716 | [2] | CONTACTOR | |
203. | 240-1913 | [12] | RESISTOR | |
204. | 240-2721 | [4] | TRANSFORMER (630-VOLT) | |
206. | 242-3341 | [4] | THERMISTOR (10-AMPERE) | |
208. | 240-2705 | [2] | BLOCK-FUSE (3-POLE) | |
209. | 240-2533 | [3] | FUSE (8-AMPERE) | |
210. | 240-1901 | [4] | BLOCK (TERMINAL END) | |
211. | 200-6265 | [3] | FUSE (4-AMPERE) | |
300. | 242-7425 Y | [2] | BOARD AS-CIRCUIT (POWER SUPPLY) | |
PARTS SHOWN ON THE GRAPHIC WITHOUT CATERPILLAR PART NUMBERS CAN BE PROCURED FROM LOCAL PARTS DISTRIBUTORS BY THE DESCRIPTIONS SHOWN | ||||
Y | SEPARATE ILLUSTRATION |
#SEBP40400167
244-4985: PANEL GP-ELECTRICAL
244-4985 PANEL GP-ELECTRICAL
S/N CZS1-UP; CZT1-UP
CONTROL, LH
PART OF 244-4982 ENCLOSURE GP-POWER SUPPLY, 294-3319 FRAME AS
S/N CZS1-UP; CZT1-UP
CONTROL, LH
PART OF 244-4982 ENCLOSURE GP-POWER SUPPLY, 294-3319 FRAME AS
Parts for your ES12F UNINTERRUPTIBLE PWR SU:
CATERPILLAR SISPos. | Part No | Qty | Parts name | Comments |
---|---|---|---|---|
200. | 202-8903 | [1] | TRANSFORMER (230-VOLT) | |
201. | 240-2704 | [2] | BLOCK-FUSE (2-POLE) | |
202. | 287-5712 Y | [1] | SWITCH GP-PUSH BUTTON (EMERGENCY POWER OFF) | |
203. | 240-2709 | [1] | TRANSFORMER | |
204. | 240-2509 | [2] | BLOCK-TERMINAL (4-POLE) | |
205. | 240-1891 | [1] | THERMISTOR (10-OHM) | |
206. | 240-2706 | [2] | BLOCK-FUSE (2-POLE) | |
207. | 240-2705 | [1] | BLOCK-FUSE (3-POLE) | |
208. | 200-6266 | [2] | FUSE (7-AMPERE) | |
209. | 240-1903 | [3] | FUSE (30-AMPERE) | |
210. | 200-6267 | [2] | FUSE (1-AMPERE) | |
211. | 240-2507 | [4] | PLATE | |
212. | 199-5099 | [2] | FUSE (10-AMPERE) | |
213. | 240-2536 | [2] | FUSE (12-AMPERE) | |
214. | 240-2682 | [1] | BLOCK-TERMINAL | |
215. | 242-3346 | [3] | FUSE (3.15-AMPERE) | |
216. | 240-2714 | [1] | RELAY (240-VOLT)(CONTROL POWER RECONFIGURE) | |
217. | 242-3365 | [1] | CONTACT-AUXILIARY (RELAY) | |
218. | 240-1901 | [2] | BLOCK (TERMINAL END) | |
301. | 282-3659 Y | [1] | BOARD AS-CIRCUIT (BREAKER CONTACTOR, STATUS) | |
302. | 242-7422 Y | [1] | BOARD AS-CIRCUIT (GENERAL PURPOSE INTERFACE) | |
PARTS SHOWN ON THE GRAPHIC WITHOUT CATERPILLAR PART NUMBERS CAN BE PROCURED FROM LOCAL PARTS DISTRIBUTORS BY THE DESCRIPTIONS SHOWN | ||||
Y | SEPARATE ILLUSTRATION |
#SEBP40400168
244-4986: PANEL GP-ELECTRICAL
244-4986 PANEL GP-ELECTRICAL
S/N CZS1-UP; CZT1-UP
LOWER CONTROL
PART OF 244-4982 ENCLOSURE GP-POWER SUPPLY, 294-3319 FRAME AS
S/N CZS1-UP; CZT1-UP
LOWER CONTROL
PART OF 244-4982 ENCLOSURE GP-POWER SUPPLY, 294-3319 FRAME AS
Parts for your ES12F UNINTERRUPTIBLE PWR SU:
CATERPILLAR SIS#SEBP40400169
244-4987: PANEL GP-ELECTRICAL
244-4987 PANEL GP-ELECTRICAL
S/N CZS1-UP; CZT1-UP
CONTACTOR
PART OF 244-4986 PANEL GP-ELECTRICAL
S/N CZS1-UP; CZT1-UP
CONTACTOR
PART OF 244-4986 PANEL GP-ELECTRICAL
Parts for your ES12F UNINTERRUPTIBLE PWR SU:
CATERPILLAR SISPos. | Part No | Qty | Parts name | Comments |
---|---|---|---|---|
600. | 244-4988 Y | [1] | FILTER AS-ELECTRICAL (INDUCTOR) | |
601. | 244-4989 Y | [1] | CONTACTOR GP | |
602. | 244-4990 Y | [1] | PANEL AS-ELECTRICAL (BASE) | |
PARTS SHOWN ON THE GRAPHIC WITHOUT CATERPILLAR PART NUMBERS CAN BE PROCURED FROM LOCAL PARTS DISTRIBUTORS BY THE DESCRIPTIONS SHOWN | ||||
Y | SEPARATE ILLUSTRATION |
Information:
OPERATOR STATION
PANEL GP
Engine News
Dealer Solution Network Now Provides Product Support for Uninterruptible Power Supply {4480}
2011/02/23
2011/02/23
New CAT Inspect Form Available for EMCP Troubleshooting and Inspection {0374, 4490, 7451, 7620}
New CAT Inspect Form Available for EMCP Troubleshooting and Inspection {0374, 4490, 7451, 7620}
New CAT Inspect Form Available for EMCP Troubleshooting and Inspection {0374, 4490, 7451, 7620}
Operation and Maintenance Manual
Battery - Replace - "APC2" Controller Board
ES12F, UPS 1000S and UPS 1200S Uninterruptible Power Supplys
ES12F, UPS 1000S and UPS 1200S Uninterruptible Power Supplys
Device Bus Network - Modbus Communications
ES12F, UPS 1000S and UPS 1200S Uninterruptible Power Supplys
ES12F, UPS 1000S and UPS 1200S Uninterruptible Power Supplys
Vacuum Pump Startup - Required Procedure After Extended Storage
ES12F, UPS 1000S and UPS 1200S Uninterruptible Power Supplys
ES12F, UPS 1000S and UPS 1200S Uninterruptible Power Supplys
Special Instruction
Configuring the Active Power Control (APC) Parameter for the Uninterruptible Power Supply ( UPS ){4480}
Configuring the Active Power Control (APC) Parameter for the Uninterruptible Power Supply ( UPS ){4480}
Configuring the Active Power Control (APC) Parameter for the Uninterruptible Power Supply ( UPS ){4480}
Troubleshooting Guide for Leaks in the Vacuum of Certain UPS Systems{4287}
Troubleshooting Guide for Leaks in the Vacuum of Certain UPS Systems{4287}
Troubleshooting Guide for Leaks in the Vacuum of Certain UPS Systems{4287}
Procedure for Testing the Vacuum Pump On Certain Uninterruptible Power Supply{4287}
Procedure for Testing the Vacuum Pump On Certain Uninterruptible Power Supply{4287}
Procedure for Testing the Vacuum Pump On Certain Uninterruptible Power Supply{4287}
Inspection and Cleaning Procedure For Certain Uninterruptible Power Supplies{4480}
Inspection and Cleaning Procedure For Certain Uninterruptible Power Supplies{4480}
Inspection and Cleaning Procedure For Certain Uninterruptible Power Supplies{4480}
Procedure For Tightening of SAE Plugs on Certain Flywheel UPS Products{1156, 4480}
Procedure For Tightening of SAE Plugs on Certain Flywheel UPS Products{1156, 4480}
Procedure For Tightening of SAE Plugs on Certain Flywheel UPS Products{1156, 4480}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.4 {4490}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.4 {4490}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.4 {4490}
Procedure for Installing Load Cell, And RPS Assembly on Each Flywheel on Certain Uninterruptible Power Supplies{4480}
Procedure for Installing Load Cell, And RPS Assembly on Each Flywheel on Certain Uninterruptible Power Supplies{4480}
Procedure for Installing Load Cell, And RPS Assembly on Each Flywheel on Certain Uninterruptible Power Supplies{4480}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.2 {4490, 7451}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.2 {4490, 7451}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.2 {4490, 7451}
Instructions for Installing AssetIQ<SUP>TM</SUP> for Commercial Generator Set Systems on Caterpillar and non-Caterpillar Products {4450, 7490}
Instructions for Installing AssetIQTM for Commercial Generator Set Systems on Caterpillar and non-Caterpillar Products {4450, 7490}
Instructions for Installing AssetIQTM for Commercial Generator Set Systems on Caterpillar and non-Caterpillar Products {4450, 7490}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.2 {4490, 7610}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.2 {4490, 7610}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.2 {4490, 7610}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.2B {1408, 4490, 7418, 7426, 7451}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.2B {1408, 4490, 7418, 7426, 7451}
Procedure to Upgrade EMCP 1, EMCP 2, EMCP 2+, EMCP 3.1, EMCP 3.2, and EMCP 3.3 to EMCP 4.2B {1408, 4490, 7418, 7426, 7451}
Systems Operation
Internal Component Preremoval Steps (4 Wire Output Cabinet)
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
Internal Component Preremoval Steps (4 Wire Transformer Cabinet)
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
General Purpose Interface PWA (4 Wire Transformer Cabinet)
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
External Source Sync PWA (4 Wire Transformer Cabinet)
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
Internal Component Preremoval Steps (Maintenance Bypass Cabinet)
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
Internal Component Preremoval Steps (Input/Output Cabinet)
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
Internal Component Preremoval Steps (Static Switch Cabinet)
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
General Purpose Interface PWA (Static Switch Cabinet)
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
Internal Component Preremoval Steps (Controls Cabinet)
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
Filter Fuse, Fuse Status Indicator and Discharge Resistor
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
Internal Component Preremoval Steps (Inverter Cabinet)
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
Internal Component Preremoval Steps (Flywheel Cabinet)
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
Testing and Adjusting
Vacuum Pump Startup - Required Procedure After Extended Storage
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
UPS 1000S/ UPS 1200S Uninterruptible Power Supplys
Service Magazine