1885638 SEGMENT GP- Caterpillar parts
Rating:
Alternative (cross code) number:
CA1885638
188-5638
1885638
CA1885638
188-5638
1885638
Weight: 163 pounds 73 kg.
Information:
"Top Engine Fan Speed"
The "Top Engine Fan Speed" parameter is used to set the top speed of the fan. Factory passwords are required."Ether Control"
The parameter for the "Ether Control" allows this feature to be enabled or disabled."Engine Prelube"
The parameter for the "Engine Prelube" allows this feature to be enabled or disabled."Variable Pitch Engine Fan"
The "Variable Pitch Engine Fan" parameter allows the variable pitch fan to be enabled or disabled."Variable Pitch Engine Fan Blade Cooling Position"
The "Variable Pitch Engine Fan Blade Cooling Position" parameter allows the customer to specify the cooling position of the engine fan blade."Engine Fan Purge Cycle Interval"
The "Engine Fan Purge Cycle Interval" parameter allows the customer to set the time interval between purges."Engine Fan Purge Cycle Duration"
The "Engine Fan Purge Cycle Duration" parameter allows the customer to set the duration of an individual purge."Engine Fan Suspend Purge"
The "Engine Fan Suspend Purge" parameter allows the suspend purge in forward gear to be enabled or disabled."Engine Fan Manual Purge"
The "Engine Fan Manual Purge" parameter allows the manual purge button to be enabled or disabled.Parameter Table
Table 2
System Configuration Parameters    
Parameter    Available Range or Options    Default    Required Password    
"Equipment ID"     17 characters     N/A     None    
"Engine Serial Number"     8 characters     N/A     None    
"FLS"     -128 to +127     0     Factory    
"FTS"     -128 to +127     0     Factory    
"Fuel Air Ratio Control Adjust (FARC)"     100 to 250     100     None    
"Engine Fan Control"     On
Off     Off     None    
"Top Engine Fan Speed"     500 to 1500 rpm     Application dependent     Factory    
"Ether Control"     Enabled
Disabled     Disabled     None    
"Engine Prelube"     Enabled
Disabled     Enabled     None    
"Variable Pitch Engine Fan"     Enabled
Disabled     Disabled     None    
"Variable Pitch Engine Fan Blade Cooling Position"     Push
Pull     Push     None    
"Engine Fan Purge Cycle Interval"     300 to 7200 sec     1200 sec     None    
"Engine Fan Purge Cycle Duration"     5 to 30 sec     15 sec     None    
"Engine Fan Suspend Purge"     Enabled
Disabled     Disabled     None    
"Engine Fan Manual Purge"     Enabled
Disabled     Enabled     None    Parameter Worksheet
Record the following information before you change any programmable parameter.
Table 3
Information from ECM    
"Equipment ID"    
   
"Engine Serial Number"    
   
"ECM Serial Number"    
   
"Personality Module Part Number"    
   
"Personality Module Release Date"    
   
"Personality Module Description"    
   
"FLS"    
   
"FTS"    
   
"FARC"    
   
"Engine Fan Control"    
   
"Top Engine Fan Speed"    
   
"Ether Control"    
   
"Engine Prelube"    
   
"Variable Pitch Engine Fan"    
   
"Variable Pitch Engine Fan Blade Cooling Position"    
   
"Engine Fan Purge Cycle Interval"    
   
"Engine Fan Purge Cycle Duration"    
   
"Engine Fan Suspend Purge"    
   
"Engine Fan Manual Purge"    
   
"Total Tattletale"    
   
Information From Engine Information Plate    
Engine Serial Number
The "Top Engine Fan Speed" parameter is used to set the top speed of the fan. Factory passwords are required."Ether Control"
The parameter for the "Ether Control" allows this feature to be enabled or disabled."Engine Prelube"
The parameter for the "Engine Prelube" allows this feature to be enabled or disabled."Variable Pitch Engine Fan"
The "Variable Pitch Engine Fan" parameter allows the variable pitch fan to be enabled or disabled."Variable Pitch Engine Fan Blade Cooling Position"
The "Variable Pitch Engine Fan Blade Cooling Position" parameter allows the customer to specify the cooling position of the engine fan blade."Engine Fan Purge Cycle Interval"
The "Engine Fan Purge Cycle Interval" parameter allows the customer to set the time interval between purges."Engine Fan Purge Cycle Duration"
The "Engine Fan Purge Cycle Duration" parameter allows the customer to set the duration of an individual purge."Engine Fan Suspend Purge"
The "Engine Fan Suspend Purge" parameter allows the suspend purge in forward gear to be enabled or disabled."Engine Fan Manual Purge"
The "Engine Fan Manual Purge" parameter allows the manual purge button to be enabled or disabled.Parameter Table
Table 2
System Configuration Parameters    
Parameter    Available Range or Options    Default    Required Password    
"Equipment ID"     17 characters     N/A     None    
"Engine Serial Number"     8 characters     N/A     None    
"FLS"     -128 to +127     0     Factory    
"FTS"     -128 to +127     0     Factory    
"Fuel Air Ratio Control Adjust (FARC)"     100 to 250     100     None    
"Engine Fan Control"     On
Off     Off     None    
"Top Engine Fan Speed"     500 to 1500 rpm     Application dependent     Factory    
"Ether Control"     Enabled
Disabled     Disabled     None    
"Engine Prelube"     Enabled
Disabled     Enabled     None    
"Variable Pitch Engine Fan"     Enabled
Disabled     Disabled     None    
"Variable Pitch Engine Fan Blade Cooling Position"     Push
Pull     Push     None    
"Engine Fan Purge Cycle Interval"     300 to 7200 sec     1200 sec     None    
"Engine Fan Purge Cycle Duration"     5 to 30 sec     15 sec     None    
"Engine Fan Suspend Purge"     Enabled
Disabled     Disabled     None    
"Engine Fan Manual Purge"     Enabled
Disabled     Enabled     None    Parameter Worksheet
Record the following information before you change any programmable parameter.
Table 3
Information from ECM    
"Equipment ID"    
   
"Engine Serial Number"    
   
"ECM Serial Number"    
   
"Personality Module Part Number"    
   
"Personality Module Release Date"    
   
"Personality Module Description"    
   
"FLS"    
   
"FTS"    
   
"FARC"    
   
"Engine Fan Control"    
   
"Top Engine Fan Speed"    
   
"Ether Control"    
   
"Engine Prelube"    
   
"Variable Pitch Engine Fan"    
   
"Variable Pitch Engine Fan Blade Cooling Position"    
   
"Engine Fan Purge Cycle Interval"    
   
"Engine Fan Purge Cycle Duration"    
   
"Engine Fan Suspend Purge"    
   
"Engine Fan Manual Purge"    
   
"Total Tattletale"    
   
Information From Engine Information Plate    
Engine Serial Number
Parts segment Caterpillar catalog:
1876365
SEGMENT
Caterpillar
Caterpillar
1874846
SEGMENT-
Caterpillar
Caterpillar
1874845
SEGMENT-
Caterpillar
Caterpillar
1856152
SEGMENT-
Caterpillar
Caterpillar
1856151
SEGMENT-
Caterpillar
Caterpillar
1793683
SEGMENT
Caterpillar
Caterpillar
1999137
SEGMENT AS.
Caterpillar
Caterpillar
1977508
SEGMENT GP-
Caterpillar
Caterpillar
1946698
SEGMENT GP-
Caterpillar
Caterpillar
1946687
SEGMENT GP-
Caterpillar
Caterpillar
1905485
SEGMENT-RIM
Caterpillar
Caterpillar
1885641
SEGMENT GP-CLA
Caterpillar
Caterpillar