Illustration 1 g01989834
Connections of the implement lockout solenoidThis diagnostic code is associated with the implement lockout solenoid. The FMI 05 means that the ECM has determined that an open in the circuit exists.The possible causes of this diagnostic code are listed below:
The energizer circuit of the solenoid is open.
The return circuit of the solenoid is open.
The solenoid has failed.
The ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0882 FMI 05 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure.Test Step 1. CHECK THE SOLENOID
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Disconnect the solenoid from the machine harness.
At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire P988-OR) to contact 2 (wire H808-WH).
Observe the status of the diagnostic code.Expected Result:The diagnostic code remains active. Then, the diagnostic code changes from FMI 05 to FMI 06 after the jumper wire is installed.Results:
YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code. Proceed to Test Step 2.
NO - The diagnostic is no longer active. The solenoid has failed.Repair: The solenoid has failed. Replace the solenoid. Verify that the new solenoid corrects the problem.STOPTest Step 2. CHECK THE HARNESS FOR AN OPEN
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connector(s) from the ECM.
The jumper wire that was installed in the previous test remains in place.
At the machine harness connector, measure the resistance from signal contact J1-24 (wire P988-OR) to contact J2-4 (wire H808-WH).Expected Result:The resistance is less than 5.0 ohms.Results:
OK - The resistance is less than 5.0 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - The resistance is greater than 5000 ohms. The resistance measurement is not correct. There is an open circuit in the machine harness.Repair: The open is in wire P988-OR or in wire H808-WH of the machine harness. Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK THE OPERATION OF THE ECMThe disconnect switch and the key start switch remain in the OFF position. The machine harness connector for the solenoid and the ECM connectors remain disconnected.
Remove the jumper wire that was installed in the last Test Step.
At the J1 connector for the ECM, use a wire removal tool to remove wire P988-OR from contact J1-24.
Reconnect the machine harness connectors to the ECM.
Turn the disconnect switch and the key start switch to the ON position.
Use a multimeter probe that is not connected to a multimeter or a similar device to make contact with the ECM at contact J1-24 through the empty space in the J1 connector.
Observe the status of the diagnostic code. Ground the other end of the multimeter probe to frame ground.Expected Result:The FMI 05 changes to a
Caterpillar parts catalog:
Parts segment Caterpillar catalog:
4876040
SEGMENT
Caterpillar
Caterpillar
4876039
SEGMENT
Caterpillar
Caterpillar
4876038
SEGMENT
Caterpillar
Caterpillar
4876037
SEGMENT
Caterpillar
Caterpillar
4876036
SEGMENT
Caterpillar
Caterpillar
4876035
SEGMENT
Caterpillar
Caterpillar
5655525
SEGMENT
Caterpillar
Caterpillar
5655524
SEGMENT
Caterpillar
Caterpillar
5655523
SEGMENT
Caterpillar
Caterpillar
5655522
SEGMENT
Caterpillar
Caterpillar
4877651
SEGMENT
Caterpillar
Caterpillar
4877650
SEGMENT
Caterpillar
Caterpillar