7E6831 SENDER-WATER TEMPERATURE Caterpillar parts
206, 3054, C4.4
Rating:
Alternative (cross code) number:
CA7E6831
7E-6831
7E6831
CA7E6831
7E-6831
7E6831
Weight: 0.20 pounds 0 kg.
EXCAVATOR, GENERATOR SET,
This part in 4 request:
Show.
This information for suppliers only!
2023-02-10
2021-09-03
2020-08-17
2019-07-04
Information:
Engine:
3508 (S/N: 23Z1-UP; CNF1-UP)
3508B (S/N: S2A1-UP; S2B1-UP; 3DM1-UP; 3DW1-UP; CNB1-UP)
3512 (S/N: 24Z1-UP; CMJ1-UP)
3512B (S/N: CMC1-UP; S2G1-UP; S2H1-UP; 8EM1-UP; 1PW1-UP; BLF1-UP)
3516 (S/N: 25Z1-UP; 73Z1-UP; CMD1-UP)
3516B (S/N: 9AN1-UP; S2P1-UP; S2R1-UP; 2FW1-UP; BPJ1-UP; PPS1-UP)
Generator Set:
3508 (S/N: 5PW1-UP)
3508B (S/N: 5KW1-UP; BGX1-UP)
3512 (S/N: 6WW1-UP; FDR1-UP; PTG1-UP; PTH1-UP)
3512B (S/N: 6GW1-UP; BRK1-UP; FDE1-UP; PTF1-UP; PTM1-UP)
3512C (S/N: SBG1-UP)
3516 (S/N: 8TW1-UP; CAL1-UP; PTD1-UP; RKT1-UP; GZX1-UP; GZR1-UP)
3516B (S/N: 8NW1-UP; FDN1-UP; FDX1-UP; GAR1-UP; GZS1-UP; GZT1-UP; LEK1-UP; PBR1-UP)
3516C (S/N: SBJ1-UP)
Power Module:
PM3508 (S/N: BLM1-UP)
PM3512 (S/N: BNR1-UP)
PM3516 (S/N: BPD1-UP)
Engine News SEBD9551, 04 August 2008, "Shutdown the Jacket Water Heater During Generator Set Operation". Disregard this article. Refer to the following article.The following canister type of jacket water heaters are supplied without AC circuitry.
200-6504 Jacket Water Heater Gp
7E-6247 Jacket Water Heater Gp
7E-6248 Jacket Water Heater Gp The customer must provide separate wiring and control. This information is stated in the price list.In order to maximize the reliability of the jacket water heaters, the canister heaters must be turned off during operation of the generator set. If the AC power input is left on during engine operation, premature failure of the thermostat can occur due to vibration during generator set operation.Add a contactor for control that is energized from the crank relay for the engine. This will ensure that the heater is turned off while the generator set is running. The contactor must be rated for either 3, 6 or 12 kW power requirement.
Illustration 1 g01525127
Wiring for the contactorRefer to Illustration 2 in order to wire the 200-6504 Jacket Water Heater Gp and the 7E-6248 Jacket Water Heater Gp for 200 to 240 volt supply.
Illustration 2 g01620614
200 to 240 volt single phase wiring for the 200-6504 Jacket Water Heater Gp and the 7E-6248 Jacket Water Heater Gp Refer to Illustration 3 in order to wire the 200-6504 Jacket Water Heater Gp and the 7E-6248 Jacket Water Heater Gp for 400 to 480 volt supply.
Illustration 3 g01525129
400 to 480 volt single phase wiring for the 200-6504 Jacket Water Heater Gp and the 7E-6248 Jacket Water Heater Gp Refer to Illustration 4 in order to wire the 7E-6247 Jacket Water Heater Gp for 120 volt supply.
Illustration 4 g01525132
120 volt single phase wiring for the 7E-6247 Jacket Water Heater Gp Refer to Illustration 5 in order to wire the 7E-6247 Jacket Water Heater Gp for 240 volt supply.
Illustration 5 g01525133
240 volt single phase wiring for the 7E-6247 Jacket Water Heater Gp If you have any questions, route any related issues through your Technical Communicator to the Dealer Solution Network (DSN).
3508 (S/N: 23Z1-UP; CNF1-UP)
3508B (S/N: S2A1-UP; S2B1-UP; 3DM1-UP; 3DW1-UP; CNB1-UP)
3512 (S/N: 24Z1-UP; CMJ1-UP)
3512B (S/N: CMC1-UP; S2G1-UP; S2H1-UP; 8EM1-UP; 1PW1-UP; BLF1-UP)
3516 (S/N: 25Z1-UP; 73Z1-UP; CMD1-UP)
3516B (S/N: 9AN1-UP; S2P1-UP; S2R1-UP; 2FW1-UP; BPJ1-UP; PPS1-UP)
Generator Set:
3508 (S/N: 5PW1-UP)
3508B (S/N: 5KW1-UP; BGX1-UP)
3512 (S/N: 6WW1-UP; FDR1-UP; PTG1-UP; PTH1-UP)
3512B (S/N: 6GW1-UP; BRK1-UP; FDE1-UP; PTF1-UP; PTM1-UP)
3512C (S/N: SBG1-UP)
3516 (S/N: 8TW1-UP; CAL1-UP; PTD1-UP; RKT1-UP; GZX1-UP; GZR1-UP)
3516B (S/N: 8NW1-UP; FDN1-UP; FDX1-UP; GAR1-UP; GZS1-UP; GZT1-UP; LEK1-UP; PBR1-UP)
3516C (S/N: SBJ1-UP)
Power Module:
PM3508 (S/N: BLM1-UP)
PM3512 (S/N: BNR1-UP)
PM3516 (S/N: BPD1-UP)
Engine News SEBD9551, 04 August 2008, "Shutdown the Jacket Water Heater During Generator Set Operation". Disregard this article. Refer to the following article.The following canister type of jacket water heaters are supplied without AC circuitry.
200-6504 Jacket Water Heater Gp
7E-6247 Jacket Water Heater Gp
7E-6248 Jacket Water Heater Gp The customer must provide separate wiring and control. This information is stated in the price list.In order to maximize the reliability of the jacket water heaters, the canister heaters must be turned off during operation of the generator set. If the AC power input is left on during engine operation, premature failure of the thermostat can occur due to vibration during generator set operation.Add a contactor for control that is energized from the crank relay for the engine. This will ensure that the heater is turned off while the generator set is running. The contactor must be rated for either 3, 6 or 12 kW power requirement.
Illustration 1 g01525127
Wiring for the contactorRefer to Illustration 2 in order to wire the 200-6504 Jacket Water Heater Gp and the 7E-6248 Jacket Water Heater Gp for 200 to 240 volt supply.
Illustration 2 g01620614
200 to 240 volt single phase wiring for the 200-6504 Jacket Water Heater Gp and the 7E-6248 Jacket Water Heater Gp Refer to Illustration 3 in order to wire the 200-6504 Jacket Water Heater Gp and the 7E-6248 Jacket Water Heater Gp for 400 to 480 volt supply.
Illustration 3 g01525129
400 to 480 volt single phase wiring for the 200-6504 Jacket Water Heater Gp and the 7E-6248 Jacket Water Heater Gp Refer to Illustration 4 in order to wire the 7E-6247 Jacket Water Heater Gp for 120 volt supply.
Illustration 4 g01525132
120 volt single phase wiring for the 7E-6247 Jacket Water Heater Gp Refer to Illustration 5 in order to wire the 7E-6247 Jacket Water Heater Gp for 240 volt supply.
Illustration 5 g01525133
240 volt single phase wiring for the 7E-6247 Jacket Water Heater Gp If you have any questions, route any related issues through your Technical Communicator to the Dealer Solution Network (DSN).
Caterpillar parts catalog:
Parts sender Caterpillar catalog:
7W1132
SENDER GP
206, 212
206, 212
1967654
SENDER
3034, 3054, 3054B, 3056, C1.5, C2.2
3034, 3054, 3054B, 3056, C1.5, C2.2
2144147
SENDER-PRESSURE
3054, 3056
3054, 3056
2144148
SENDER-TEMPERATURE
3054, 3056
3054, 3056
2144148
SENDER-TEMPERATURE
3054, 3056
3054, 3056
2144147
SENDER-PRESSURE
3054, 3056
3054, 3056
1967654
SENDER
3034, 3054, 3054B, 3056, C1.5, C2.2
3034, 3054, 3054B, 3056, C1.5, C2.2
8D1266
SENDER-PRESSURE
3306, 3406, 3406B, 3406C, 631D, 650B, 666B, 768B, 769, 772, 773, 988B, 992C
3306, 3406, 3406B, 3406C, 631D, 650B, 666B, 768B, 769, 772, 773, 988B, 992C
1091586
SENDER
3304B, 3306B
3304B, 3306B
6I1793
SENDER-PRESSURE
3606, 3608, 3612, 3616
3606, 3608, 3612, 3616
7E0028
SENDER-PRESSURE
3606, 3608, 3612, 3616, C280-12, C280-16, C280-6, C280-8, G3606, G3608, G3612, G3616
3606, 3608, 3612, 3616, C280-12, C280-16, C280-6, C280-8, G3606, G3608, G3612, G3616
2305499
SENDER
C1.5, C2.2
C1.5, C2.2