1W5559 SENSOR GP-SPEED Caterpillar parts
3208
Rating:
Alternative (cross code) number:
CA1W5559
1W-5559
1W5559
CA1W5559
1W-5559
1W5559
Weight: 0.39 pounds 0 kg.
GEN SET ENGINE, MARINE ENGINE,
Compatible equipment models: 1W5559:
Information:
There are two separate procedures that must be performed in order to program the EMCP 3 digital inputs. The first procedure involves programming the active state of the input as either "Active High" or as "Active Low". The second procedure involves programming the event input functions.Digital Inputs
The main purpose for the digital inputs is to add additional monitoring capabilities for the engine or the generator. The inputs can be configured by navigating to the "EVENT I/P FUNCTIONS" parameter under the "SETPOINTS" menu.Note: There are eight digital inputs on EMCP 3.2 and EMCP 3.3. There are six digital inputs on EMCP 3.1. On all three levels of controls, the first and second digital inputs are dedicated and cannot be programmed.The digital inputs of the EMCP 3 are tied to an internal pull-up resistor inside the control. Therefore, if there is no connection to a digital input, then the digital input will read as a logical high. A ground or battery negative input should be wired to each EMCP 3 digital input. If an active high configuration is desired, then the ground or battery negative input should be wired through a normally closed switch. If an Active Low configuration is desired, then the ground or battery negative input should be wired through a normally open switch.Digital input #1 is dedicated for Emergency Stop and digital input #2 is dedicated for Remote Initiate. The other four or six inputs can be configured to trigger alarms or shutdowns in the EMCP 3. In the EMCP 3 software, digital inputs 3 through 8 are linked to functions that are called "EVENT INPUT FUNCTIONS". In the EMCP 3.1 software, digital inputs 3 through 6 are linked to functions that are called "EVENT INPUT FUNCTIONS". Digital inputs #1 and #2 are dedicated inputs. Therefore, digital input #3 is linked to event input function #1, digital input #4 is linked to event input function #2, and so on. Refer to Illustration 1.
Illustration 1 g01228372
Digital Input #1 - Digital input #1 is used for "Emergency Stop". The input must be wired to battery negative through an emergency stop switch. The input can be set to activate on an active high (normally closed contact) or an active low (normally open contact). If the operator wants to enable the "Reduced Power Mode", then the emergency stop must be configured for active low.ReferenceTesting and Adjusting , "Electronic Control Module (Generator Set) - Configure"Activating the emergency stop input will either cause the generator set to stop immediately or will prevent the generator set from starting. Once digital input #1 goes active, the engine will not start until the event is reset.ReferenceSystem Operation , "Event Resetting"Digital Input #2 - Digital input #2 is used for remotely starting and stopping the generator set. The input must be wired to battery negative through a "Remote Initiate" switch. The input can be set to activate on an active high (normally closed contact) or an active low (normally open contact). If the input is active, and the
The main purpose for the digital inputs is to add additional monitoring capabilities for the engine or the generator. The inputs can be configured by navigating to the "EVENT I/P FUNCTIONS" parameter under the "SETPOINTS" menu.Note: There are eight digital inputs on EMCP 3.2 and EMCP 3.3. There are six digital inputs on EMCP 3.1. On all three levels of controls, the first and second digital inputs are dedicated and cannot be programmed.The digital inputs of the EMCP 3 are tied to an internal pull-up resistor inside the control. Therefore, if there is no connection to a digital input, then the digital input will read as a logical high. A ground or battery negative input should be wired to each EMCP 3 digital input. If an active high configuration is desired, then the ground or battery negative input should be wired through a normally closed switch. If an Active Low configuration is desired, then the ground or battery negative input should be wired through a normally open switch.Digital input #1 is dedicated for Emergency Stop and digital input #2 is dedicated for Remote Initiate. The other four or six inputs can be configured to trigger alarms or shutdowns in the EMCP 3. In the EMCP 3 software, digital inputs 3 through 8 are linked to functions that are called "EVENT INPUT FUNCTIONS". In the EMCP 3.1 software, digital inputs 3 through 6 are linked to functions that are called "EVENT INPUT FUNCTIONS". Digital inputs #1 and #2 are dedicated inputs. Therefore, digital input #3 is linked to event input function #1, digital input #4 is linked to event input function #2, and so on. Refer to Illustration 1.
Illustration 1 g01228372
Digital Input #1 - Digital input #1 is used for "Emergency Stop". The input must be wired to battery negative through an emergency stop switch. The input can be set to activate on an active high (normally closed contact) or an active low (normally open contact). If the operator wants to enable the "Reduced Power Mode", then the emergency stop must be configured for active low.ReferenceTesting and Adjusting , "Electronic Control Module (Generator Set) - Configure"Activating the emergency stop input will either cause the generator set to stop immediately or will prevent the generator set from starting. Once digital input #1 goes active, the engine will not start until the event is reset.ReferenceSystem Operation , "Event Resetting"Digital Input #2 - Digital input #2 is used for remotely starting and stopping the generator set. The input must be wired to battery negative through a "Remote Initiate" switch. The input can be set to activate on an active high (normally closed contact) or an active low (normally open contact). If the input is active, and the
Caterpillar parts catalog:
Parts sensor Caterpillar catalog:
1020050
SENSOR GP-TEMPERATURE
3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C15, C18, G3304, G3306, G3306B, G3406, G3412, G3508, G3512, G3516, PM3412, P...
3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C15, C18, G3304, G3306, G3306B, G3406, G3412, G3508, G3512, G3516, PM3412, P...
1342252
SENSOR GP-TEMPERATURE
24M, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3406E, 3408, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 613G, 621G, 621H, 621K, 623G, 623H, 623K, 623K LRC, 627G, 627H, ...
24M, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3406E, 3408, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 613G, 621G, 621H, 621K, 623G, 623H, 623K, 623K LRC, 627G, 627H, ...
4P5963
SENSOR GP-SPEED
3208, C-12, C11, C13, C13 XQ350, C15, C27, C32, C9, C9.3, CX31-C13I, CX31-C9I, TH31-E61, TH35-C11I, TH35-C13I, TH48-E70
3208, C-12, C11, C13, C13 XQ350, C15, C27, C32, C9, C9.3, CX31-C13I, CX31-C9I, TH31-E61, TH35-C11I, TH35-C13I, TH48-E70
2W8918
SENSOR GP-SPEED
3116, 3176B, 3176C, 3196, 3208, 3516B, 75, 994, C-10, C-12, C11, C12, C13, C27, C32, C9, CX31-C13I, CX31-C9I, G3306, PR-1000, TH31-E61, TH35-C11I, TH35-C13I, TH48-E70
3116, 3176B, 3176C, 3196, 3208, 3516B, 75, 994, C-10, C-12, C11, C12, C13, C27, C32, C9, CX31-C13I, CX31-C9I, G3306, PR-1000, TH31-E61, TH35-C11I, TH35-C13I, TH48-E70
1638516
SENSOR GP-PRESSURE
3208, 3304, 3304B, 3306, 3306B, 3406B, 3408, 3408B, 3408C, 3412, 3412C, 3508, 3512, 3516, G3406, G3408, G3412, G3508, G3512, G3516, G3606, G3608, G3612, G3616, PM3412, SCT673, SPS342, SPT342
3208, 3304, 3304B, 3306, 3306B, 3406B, 3408, 3408B, 3408C, 3412, 3412C, 3508, 3512, 3516, G3406, G3408, G3412, G3508, G3512, G3516, G3606, G3608, G3612, G3616, PM3412, SCT673, SPS342, SPT342
2168684
SENSOR GP-PRESSURE
3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3412, 3412C, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 793C, 854G, 992G, C15, C18, C9, CX31-C13I, CX31-C15I, CX31-C18I, CX31-C9I, CX35-C1...
3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3412, 3412C, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 793C, 854G, 992G, C15, C18, C9, CX31-C13I, CX31-C15I, CX31-C18I, CX31-C9I, CX35-C1...
1070174
SENSOR AS-COOLANT LEVEL
3116, 3126, 3208, 3306B, 3406B, 3406C, 3412
3116, 3126, 3208, 3306B, 3406B, 3406C, 3412
4P5820
SENSOR GP-SPEED
3116, 3126B, 3176C, 3196, 3208, 330C, 330C FM, 330C L, 330C MH, 330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 340D L, 340D2 L, 345C MH, 345D, 345D L, 345D L VG, 349D,...
3116, 3126B, 3176C, 3196, 3208, 330C, 330C FM, 330C L, 330C MH, 330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 340D L, 340D2 L, 345C MH, 345D, 345D L, 345D L VG, 349D,...
1077142
SENSOR GP-PRESSURE
3114, 3116, 3208, 3304, 3306B, 3406B, 3408B, 3508, 3512, G3406, G3408, G3412, G3508, G3512, G3516, G3606, G3608, G3612, G3616
3114, 3116, 3208, 3304, 3306B, 3406B, 3408B, 3508, 3512, G3406, G3408, G3412, G3508, G3512, G3516, G3606, G3608, G3612, G3616
7X6182
SENSOR AS-PRESS
3176, 3208, 3304, 3406B, 3508, 3512, 75
3176, 3208, 3304, 3406B, 3508, 3512, 75
7X1602
SENSOR AS-PRESS
3114, 3116, 3176, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3408, 3408B, 3412, 3412C, 3508, 3512, 3516, 75, G3512, G3516, G3606, G3608, G3612
3114, 3116, 3176, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3408, 3408B, 3412, 3412C, 3508, 3512, 3516, 75, G3512, G3516, G3606, G3608, G3612
1159609
SENSOR GP-TEMPERATURE
3508, 3512, 3512B, 3516, G3516
3508, 3512, 3512B, 3516, G3516
1027532
SENSOR GP-TEMPERATURE
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 5130, 5230, 776C, 784B, 785, 785B, 789B, 793B, D11N, D11R, SPF343, SPS343, SPT343
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 5130, 5230, 776C, 784B, 785, 785B, 789B, 793B, D11N, D11R, SPF343, SPS343, SPT343
0975375
SENSOR
RT50
RT50
3E6381
SENSOR AS-PRESSURE
3176B, 3406E, 75C
3176B, 3406E, 75C
7X1602
SENSOR AS-PRESS
3114, 3116, 3176, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3408, 3408B, 3412, 3412C, 3508, 3512, 3516, 75, G3512, G3516, G3606, G3608, G3612
3114, 3116, 3176, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3408, 3408B, 3412, 3412C, 3508, 3512, 3516, 75, G3512, G3516, G3606, G3608, G3612
7T7757
SENSOR
428, 769C, 773B
428, 769C, 773B
3664746
SENSOR GP-PARTICLE
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, C175-16, G3606, G3608, G3616
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, C175-16, G3606, G3608, G3616
1036091
SENSOR GP-PRESSURE
24H, 3406E, 3412E, 3508, 3508B, 3512, 3512B, 3516, 3516B, 5130B, 657E, 773B, 773D, 775D, 776C, 776D, 777D, 784B, 785B, 789B, 793B, 793C, 836, 990 II, 992C, 992G, D10R, D350E II, D400E II, D9R
24H, 3406E, 3412E, 3508, 3508B, 3512, 3512B, 3516, 3516B, 5130B, 657E, 773B, 773D, 775D, 776C, 776D, 777D, 784B, 785B, 789B, 793B, 793C, 836, 990 II, 992C, 992G, D10R, D350E II, D400E II, D9R
1638523
SENSOR GP-PRESSURE
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C280-6, G3512E, G3516B, G3516C, G3516E, G3520B, G3520C, G3520E, G3606, G3606B, G3608, G3612, G3616, PMG3516, SPF343, SPS343, SPT343
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C280-6, G3512E, G3516B, G3516C, G3516E, G3520B, G3520C, G3520E, G3606, G3606B, G3608, G3612, G3616, PMG3516, SPF343, SPS343, SPT343
1638522
SENSOR GP-PRESSURE
3508, 3508B, 3512, 3512B, 3516, 3516B, SPF343, SPS343, SPT343
3508, 3508B, 3512, 3512B, 3516, 3516B, SPF343, SPS343, SPT343
2616849
SENSOR GP-EXHAUST TEMPERATURE
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 5130, 5230, 784B, 785B, 789B, 793B, SPF343, SPS343, SPT343
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 5130, 5230, 784B, 785B, 789B, 793B, SPF343, SPS343, SPT343
9X7860
SENSOR AS-SPEED
3408B, 3408C, 3412
3408B, 3408C, 3412