Illustration 1 g01359867
Schematic of the Right Auger Reverse SolenoidThis diagnostic code is associated with the Right Auger Reverse Solenoid. The FMI 03 means that the Machine ECM has detected that the voltage of the solenoid circuit is above normal or that the ECM has detected voltage in the circuit when no voltage should be present.Note: The Machine ECM is located inside the Center Console.Conditions that could cause this diagnostic code to be activated are:
The energize circuit of the solenoid is shorted to another voltage source.
The ECM has failed. This situation is unlikely.Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure, and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. System Response:When this diagnostic code is active, the following occurs:
Right auger will run at full speed reverse.
Operator station fault lamp is active.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT
Turn the disconnect switch and the key start switch to the OFF position.
Disconnect the machine harness at the solenoid for the Right Auger Reverse hydraulic valve. Disconnect the machine harness connectors J1 and J2 from the ECM.
At the machine harness ECM connectors, measure the resistance from contact J1-62 (wire K967-WH) to all of the other contacts that are used in the J1 and J2 connectors for the ECM.Expected Result:Each resistance measurement is greater than 5000 ohms. Results:
YES - Each resistance measurement is greater than 5000 ohms. The resistance measurement does not indicate a short in the machine harness. Proceed to Test Step 2.
NO - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. Repair: The short is between wire K967-WH and the circuit that has a low resistance measurement.For information on testing for short circuits and finding short circuits, refer to Troubleshooting, "Wiring Harness (Short Circuit) - Test". Repair the machine harness or replace machine harness.STOPTest Step 2. CHECK THE OPERATION OF THE ECMThe disconnect switch and the key start switch remain in the OFF position. The machine harness connectors for the solenoid and the ECM remain disconnected.
At the machine harness connector J1 for the ECM, use a 151-6320 Removal Tool to remove the solenoid energize wire K967-WH and socket at contact J1-62 from the harness connector.
Reconnect the machine harness J1 and J2 connectors to the ECM.
Turn the disconnect switch and the key start switch to the ON position.
Observe the status of the active
Parts sfwr Caterpillar catalog:
3142398
SFWR GP-A2006
Caterpillar
Caterpillar
3142382
SFWR GP-A5007
Caterpillar
Caterpillar
3142378
SFWR GP-A2000
Caterpillar
Caterpillar
3139588
SFWR GP-A4002
Caterpillar
Caterpillar
3139112
SFWR GP-A3000
Caterpillar
Caterpillar
3132534
SFWR GP-A4008
Caterpillar
Caterpillar
3146288
SFWR GP-A1004
Caterpillar
Caterpillar
3145035
SFWR GP-A4010
Caterpillar
Caterpillar
3145033
SFWR GP-A4010
Caterpillar
Caterpillar
3145031
SFWR GP-A4010
Caterpillar
Caterpillar
3145029
SFWR GP-A4010
Caterpillar
Caterpillar
3145027
SFWR GP-A4010
Caterpillar
Caterpillar