1685024 SHAFT Caterpillar parts
AP-1055D, AP-600D, AP-655C, AP-655D, AP-800C, AP-800D, AP-900B, AP1000E, AP1055E, AP555E, BG-225B, BG-2455D, BG-260D, BG1000E, BG1055E, BG500E, BG600D, BG655D, CP-433C, CS-431C, CS-433C
Rating:
Alternative (cross code) number:
CA1685024
168-5024
1685024
CA1685024
168-5024
1685024
Weight: 2 pounds 0 kg.
ASPHALT PAVER, VIBRATORY COMPACTOR,
Compatible equipment models: 1685024:
Information:
Network Switch
A network switch is required to connect the computing hardware. Managed switches supporting Simple Network Management Protocol (SNMP) allow monitoring of traffic and can assist in diagnosis of problems. Managed switches supporting Simple Network Management Protocol (SNMP) are recommended by Catepillar.
Table 8
Requirements    
Description    Specification    
Network Switch     One required    
Ports     Eight "100/1000 Mbps Ethernet RJ45" (1)    
Managed     Preferred    
( 1 ) MinimumEthernet Bulkhead
Refer to Table 9 for the recommended bulkhead to be installed on the network enclosure. Installation of the recommended bulkhead will allow easy connection of Caterpillar supplied Ethernet cables.
Table 9
Requirements    
Ethernet Bulkhead Connection    Part Number    
"M12 4 Pin D Code - RJ45 Female (Straight)"     Amphenol "(LTWSR-000400-0FF-IS001)"    
"M12 4 Pin D Code - RJ45 Female (Right Angle)"     Amphenol "(LTWSR-000400-0FF-ES001)"    Uninterruptible Power Supply (UPS)
A UPS is recommended to avoid data corruption or loss due to a power outage. Hardware should be selected to match specific country requirements.
Table 10
Requirements    
Description    Specification    
Uninterruptible Power Supply     One required    
VMware ESXi     Supported (1)    
Managed     Preferred    
( 1 ) Support for VMware ESXi 4.1, to permit safe management of the Virtual Machine upon loss of powerMobile Automation Operator Station Hardware
Computer hardware for use in a mobile environment should be selected to meet similar performance specifications as for a fixed installation. Computer hardware for use in a mobile environment should also have added environmental requirements. Refer to Table 11 for mobile environment computer hardware requirements.
Table 11
Requirements    
Description    Specification    
Operating Temperature    
−5° to 40°C (23° to 104°F)    
Relative Humidity     Less than 90% Relative Humidity (
40° C (104° F) non-condensing)    
Operating Vibration     0.4 Grms, random, 10 to 500 Hz, X,Y,Z 3 Axes, 0.5 hour/axis    
Operating Shock     8G, half sine, 11ms duration, X,Y,Z 3 axes, six directions, 3 shocks/direction    
Solid State Hard Drive or Drives     Recommended    Customer Requirements Checklist
Table 12
   Item    Quantity Required    Notes:    
Hardware     48V Power Supply            
3 Pole Mini Change Bulkhead        
Site Server Hardware        
Operator Console PC Hardware        
AIS Console Hardware        
Network Switch        
Ethernet Cabling (RJ45 to M12)        
Uninterruptible Power Supply        
Mounting Hardware (1)        
Software     VMware ESXi 4.1            
Siemens "WinCC RT V7 SP3"        
Console Operating Systems (2)        
VNC        
UPS Management Agent for VMware ESXi 4.1        
( 1 ) For Automation Operator Station Hardware, LARN Infrastructure, AIS Infrastructure
( 2 ) Windows XP Professional
A network switch is required to connect the computing hardware. Managed switches supporting Simple Network Management Protocol (SNMP) allow monitoring of traffic and can assist in diagnosis of problems. Managed switches supporting Simple Network Management Protocol (SNMP) are recommended by Catepillar.
Table 8
Requirements    
Description    Specification    
Network Switch     One required    
Ports     Eight "100/1000 Mbps Ethernet RJ45" (1)    
Managed     Preferred    
( 1 ) MinimumEthernet Bulkhead
Refer to Table 9 for the recommended bulkhead to be installed on the network enclosure. Installation of the recommended bulkhead will allow easy connection of Caterpillar supplied Ethernet cables.
Table 9
Requirements    
Ethernet Bulkhead Connection    Part Number    
"M12 4 Pin D Code - RJ45 Female (Straight)"     Amphenol "(LTWSR-000400-0FF-IS001)"    
"M12 4 Pin D Code - RJ45 Female (Right Angle)"     Amphenol "(LTWSR-000400-0FF-ES001)"    Uninterruptible Power Supply (UPS)
A UPS is recommended to avoid data corruption or loss due to a power outage. Hardware should be selected to match specific country requirements.
Table 10
Requirements    
Description    Specification    
Uninterruptible Power Supply     One required    
VMware ESXi     Supported (1)    
Managed     Preferred    
( 1 ) Support for VMware ESXi 4.1, to permit safe management of the Virtual Machine upon loss of powerMobile Automation Operator Station Hardware
Computer hardware for use in a mobile environment should be selected to meet similar performance specifications as for a fixed installation. Computer hardware for use in a mobile environment should also have added environmental requirements. Refer to Table 11 for mobile environment computer hardware requirements.
Table 11
Requirements    
Description    Specification    
Operating Temperature    
−5° to 40°C (23° to 104°F)    
Relative Humidity     Less than 90% Relative Humidity (
40° C (104° F) non-condensing)    
Operating Vibration     0.4 Grms, random, 10 to 500 Hz, X,Y,Z 3 Axes, 0.5 hour/axis    
Operating Shock     8G, half sine, 11ms duration, X,Y,Z 3 axes, six directions, 3 shocks/direction    
Solid State Hard Drive or Drives     Recommended    Customer Requirements Checklist
Table 12
   Item    Quantity Required    Notes:    
Hardware     48V Power Supply            
3 Pole Mini Change Bulkhead        
Site Server Hardware        
Operator Console PC Hardware        
AIS Console Hardware        
Network Switch        
Ethernet Cabling (RJ45 to M12)        
Uninterruptible Power Supply        
Mounting Hardware (1)        
Software     VMware ESXi 4.1            
Siemens "WinCC RT V7 SP3"        
Console Operating Systems (2)        
VNC        
UPS Management Agent for VMware ESXi 4.1        
( 1 ) For Automation Operator Station Hardware, LARN Infrastructure, AIS Infrastructure
( 2 ) Windows XP Professional
Cat SIS web machinery list:
Parts shaft Caterpillar catalog:
1170620
SHAFT
10 FT, AP-800C, BG-225B, BG-225C
10 FT, AP-800C, BG-225B, BG-225C
1931311
SHAFT AS
10-20B, 8-16B, AP-1055D, AP-600D, AP-655D, AP-800C, AP-800D, AS2251, AS2252C, AS2301, AS2302, AS2302C, AS3251C, AS3301C, AS4252C, BG-225B, BG-2455D, BG-260D
10-20B, 8-16B, AP-1055D, AP-600D, AP-655D, AP-800C, AP-800D, AS2251, AS2252C, AS2301, AS2302, AS2302C, AS3251C, AS3301C, AS4252C, BG-225B, BG-2455D, BG-260D
1191409
SHAFT AS
10 FT, 10B, 8 FT, AP-800C, BG-225B, BG-245C
10 FT, 10B, 8 FT, AP-800C, BG-225B, BG-245C
1155742
SHAFT AS
10 FT, 10B, 8 FT, AP-800C, BG-225B
10 FT, 10B, 8 FT, AP-800C, BG-225B
1155739
SHAFT AS
10 FT, 10B, 8 FT, AP-800C, BG-225B
10 FT, 10B, 8 FT, AP-800C, BG-225B
2227155
SHAFT AS
10 FT, 8-16B
10 FT, 8-16B
1033583
SHAFT-AUGER
AP-650B, AP-800C, AP-800D, BG-225B, BG-225C
AP-650B, AP-800C, AP-800D, BG-225B, BG-225C
1552953
SHAFT-COUPLING
10-20B, 10B, AP-1000B, AP-1055B, AP-1055D, AP-600D, AP-650B, AP-655C, AP-655D, AP-800C, AP-800D, AP-900B, AP1000E, AP1055E, AP555E, BG-225B, BG-225C, BG-2455C, BG-2455D, BG-245C, BG-260D, BG1000E, BG1...
10-20B, 10B, AP-1000B, AP-1055B, AP-1055D, AP-600D, AP-650B, AP-655C, AP-655D, AP-800C, AP-800D, AP-900B, AP1000E, AP1055E, AP555E, BG-225B, BG-225C, BG-2455C, BG-2455D, BG-245C, BG-260D, BG1000E, BG1...
1127093
SHAFT-INPUT
AP-800C, AP-800D, BG-225B
AP-800C, AP-800D, BG-225B
0870629
SHAFT
AP-1000B, AP-1055B, AP-1055D, AP-1200, AP-600D, AP-650B, AP-655C, AP-655D, AP-800C, AP-800D, AP-900B, BG-225B, BG-225C, BG-2455C, BG-2455D, BG-245C, BG-260D, BG600D, BG655D, RM-250C, RR-250, RR-250B, ...
AP-1000B, AP-1055B, AP-1055D, AP-1200, AP-600D, AP-650B, AP-655C, AP-655D, AP-800C, AP-800D, AP-900B, BG-225B, BG-225C, BG-2455C, BG-2455D, BG-245C, BG-260D, BG600D, BG655D, RM-250C, RR-250, RR-250B, ...
1931325
SHAFT AS
AP-800C, AS2252C, AS2301, AS2302, BG-225B, BG-260D
AP-800C, AS2252C, AS2301, AS2302, BG-225B, BG-260D
6R1708
SHAFT
AP-800C, AP-800D, BG-225B, CP-563, CS-533
AP-800C, AP-800D, BG-225B, CP-563, CS-533