1S4467 SHAFT Caterpillar parts
D5, D6C
Rating:
Alternative (cross code) number:
CA1S4467
1S-4467
1S4467
CA1S4467
1S-4467
1S4467
Weight: 8 pounds 3 kg.
TRACK-TYPE TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$51.92
15 Feb 2024
0.28[0.13] Pounds
Amazon.com
WVE by NTK 1S4467 Windshield Wiper Switch, 1 Pack
WVE by NTK Wiper switch controls the activation and speed of the wiper motor and in some models also controls the washer || When not replaced, wipers may run continually, not function or function at only one speed || Designed to meet or exceed OE specifications in form, fit and function || Global coverage for import and/or domestic applications
WVE by NTK Wiper switch controls the activation and speed of the wiper motor and in some models also controls the washer || When not replaced, wipers may run continually, not function or function at only one speed || Designed to meet or exceed OE specifications in form, fit and function || Global coverage for import and/or domestic applications
$55.19
09 Nov 2023
0.28[0.13] pounds
Amazon.com
WVE by NTK 1S4467 Windshield Wiper Switch, 1 Pack
WVE by NTK Wiper switch controls the activation and speed of the wiper motor and in some models also controls the washer || When not replaced, wipers may run continually, not function or function at only one speed || Designed to meet or exceed OE specifications in form, fit and function || Global coverage for import and/or domestic applications
WVE by NTK Wiper switch controls the activation and speed of the wiper motor and in some models also controls the washer || When not replaced, wipers may run continually, not function or function at only one speed || Designed to meet or exceed OE specifications in form, fit and function || Global coverage for import and/or domestic applications
$63.56
16 Jul 2021
0.28[0.13] Pounds
Amazon.com
WVE by NTK 1S4467 Windshield Wiper Switch, 1 Pack
WVE by NTK Wiper switch controls the activation and speed of the wiper motor and in some models also controls the washer || When not replaced, wipers may run continually, not function or function at only one speed || Designed to meet or exceed OE specifications in form, fit and function || Global coverage for import and/or domestic applications
WVE by NTK Wiper switch controls the activation and speed of the wiper motor and in some models also controls the washer || When not replaced, wipers may run continually, not function or function at only one speed || Designed to meet or exceed OE specifications in form, fit and function || Global coverage for import and/or domestic applications
Information:
Handling
Follow all local regulations covering transport and handling. DEF transport temperature is recommended to be −5° C (23° F) to 25° C (77° F). All transfer equipment and intermediate containers should be used exclusively for DEF. Containers should not be reused for any other fluids. Ensure that transfer equipment is made from DEF-compatible materials. Recommended material for hoses and other non-metallic transfer equipment include:
Nitrile Rubber (NBR)
Fluoroelastomer (FKM)
Ethylene Propylene Diane Ionomer (EPDM)The condition of hoses and other nonmetallic items that are used with DEF should be monitored for signs of degradation. DEF leaks are easily recognizable by white urea crystals that accumulate at the site of the leak. Solid urea can be corrosive to galvanized or unalloyed steel, aluminum, copper, and brass. Leaks should be repaired immediately to avoid damage to surrounding hardware.Cleanliness
Contaminants can degrade the quality and life of DEF. Filtering DEF is recommended when dispensed into the DEF tank. Filters should be compatible with DEF and should be used exclusively with DEF. Check with the filter supplier to confirm compatibility with DEF before using. Mesh-type filters using compatible metals, such as stainless steel, are recommended. Paper (cellulose) media and some synthetic filter media are not recommended because of degradation during use.Care should be taken when dispensing DEF. Spills should be cleaned immediately. Machine or engine surfaces should be wiped clean and rinsed with water. Caution should be used when dispensing DEF near an engine that has recently been running.Note: Spilling DEF onto hot components may cause the release of ammonia vapors. Do not breathe ammonia vapors. Do not clean up any spills with bleach.Stability
DEF fluid is stable when stored and handled properly. The quality of DEF rapidly degrades when stored at high temperatures. The ideal storage temperature for DEF is between −9° C (15.8° F) and 25° C (77° F). DEF that is stored above 35° C (95° F) for longer than 1 month must be tested before use. Testing should evaluate Urea Percentage, Alkalinity as NH3 and Biuret content.The length of storage of DEF is listed in the following table:
Table 3
Storage Temperature    Expected DEF Life    
Below
25° C (77° F)     18 months    
25° C (77° F) to
30° C (86° F)     12 months    
30° C (86° F) to
35° C (95° F)     6 months    
Above
35° C (95° F)     test quality before use    Refer to "ISO 22241" document series for more information about DEF quality control.Note: Dispose of all fluids according to applicable regulations and mandates.General Characteristics of DEF
For detailed information on the requirements and characteristics of DEF, refer "ISO 22241". For a quick reference, typical characteristics of DEF are given in Table 4.
Table 4
Characteristics for Urea Solutions    
Property     Unit     DEF 32.5 percent     Urea Solution 40 percent    
Urea content         32.5 percent (1)     40 percent (2)    
Alkalinity as NH3     Percent     0.2     0.2    
Density at
20° C (68° F)     g/L     1.087 - 1.093 (3)  
Follow all local regulations covering transport and handling. DEF transport temperature is recommended to be −5° C (23° F) to 25° C (77° F). All transfer equipment and intermediate containers should be used exclusively for DEF. Containers should not be reused for any other fluids. Ensure that transfer equipment is made from DEF-compatible materials. Recommended material for hoses and other non-metallic transfer equipment include:
Nitrile Rubber (NBR)
Fluoroelastomer (FKM)
Ethylene Propylene Diane Ionomer (EPDM)The condition of hoses and other nonmetallic items that are used with DEF should be monitored for signs of degradation. DEF leaks are easily recognizable by white urea crystals that accumulate at the site of the leak. Solid urea can be corrosive to galvanized or unalloyed steel, aluminum, copper, and brass. Leaks should be repaired immediately to avoid damage to surrounding hardware.Cleanliness
Contaminants can degrade the quality and life of DEF. Filtering DEF is recommended when dispensed into the DEF tank. Filters should be compatible with DEF and should be used exclusively with DEF. Check with the filter supplier to confirm compatibility with DEF before using. Mesh-type filters using compatible metals, such as stainless steel, are recommended. Paper (cellulose) media and some synthetic filter media are not recommended because of degradation during use.Care should be taken when dispensing DEF. Spills should be cleaned immediately. Machine or engine surfaces should be wiped clean and rinsed with water. Caution should be used when dispensing DEF near an engine that has recently been running.Note: Spilling DEF onto hot components may cause the release of ammonia vapors. Do not breathe ammonia vapors. Do not clean up any spills with bleach.Stability
DEF fluid is stable when stored and handled properly. The quality of DEF rapidly degrades when stored at high temperatures. The ideal storage temperature for DEF is between −9° C (15.8° F) and 25° C (77° F). DEF that is stored above 35° C (95° F) for longer than 1 month must be tested before use. Testing should evaluate Urea Percentage, Alkalinity as NH3 and Biuret content.The length of storage of DEF is listed in the following table:
Table 3
Storage Temperature    Expected DEF Life    
Below
25° C (77° F)     18 months    
25° C (77° F) to
30° C (86° F)     12 months    
30° C (86° F) to
35° C (95° F)     6 months    
Above
35° C (95° F)     test quality before use    Refer to "ISO 22241" document series for more information about DEF quality control.Note: Dispose of all fluids according to applicable regulations and mandates.General Characteristics of DEF
For detailed information on the requirements and characteristics of DEF, refer "ISO 22241". For a quick reference, typical characteristics of DEF are given in Table 4.
Table 4
Characteristics for Urea Solutions    
Property     Unit     DEF 32.5 percent     Urea Solution 40 percent    
Urea content         32.5 percent (1)     40 percent (2)    
Alkalinity as NH3     Percent     0.2     0.2    
Density at
20° C (68° F)     g/L     1.087 - 1.093 (3)  
Caterpillar parts catalog:
Parts shaft Caterpillar catalog:
8H9804
SHAFT-PUMP IDLER
120G, 12E, 12G, 140B, 140G, 14G, 1673, 1673C, 1676, 215, 225, 235, 3160, 3208, 3304, 3306, 3408, 3412, 518, 613B, 613C, 627B, 637D, 650B, 651E, 657E, 941, 950, 955L, 977H, 988B, 992, 992C, CS-551, D33...
120G, 12E, 12G, 140B, 140G, 14G, 1673, 1673C, 1676, 215, 225, 235, 3160, 3208, 3304, 3306, 3408, 3412, 518, 613B, 613C, 627B, 637D, 650B, 651E, 657E, 941, 950, 955L, 977H, 988B, 992, 992C, CS-551, D33...
2S6838
SHAFT
1674, 1693, 3306, 631C, 941, 950, 951B, 966C, D334, D343, D6C, D7F, D8H
1674, 1693, 3306, 631C, 941, 950, 951B, 966C, D334, D343, D6C, D7F, D8H
4N4320
SHAFT ASSEM.
120B, 120G, 12G, 130G, 140B, 140G, 14G, 1673C, 215, 225, 235, 518, 528, 627B, 637D, 920, 930, 941, 950, 951B, 955K, 955L, 966C, 977K, D4D, D4E, D5, D5B, D6C, D6D, D7F, D7G
120B, 120G, 12G, 130G, 140B, 140G, 14G, 1673C, 215, 225, 235, 518, 528, 627B, 637D, 920, 930, 941, 950, 951B, 955K, 955L, 966C, 977K, D4D, D4E, D5, D5B, D6C, D6D, D7F, D7G
2H4498
SHAFT
561B, 561C, 955C, 977D, D4D, D4E, D4E SR, D5, D5B, D5E, D6C, D6D, D6E SR, D7F, D7G
561B, 561C, 955C, 977D, D4D, D4E, D4E SR, D5, D5B, D5E, D6C, D6D, D6E SR, D7F, D7G
9M2020
SHAFT
572G, 977K, D6C, D6D, D6E, D6G2 LGP, D6G2 XL, D7G, D7G2
572G, 977K, D6C, D6D, D6E, D6G2 LGP, D6G2 XL, D7G, D7G2
8M8652
SHAFT
572G, 621, 621B, 623, 623B, 627, 627B, 631C, 631D, 633D, 637, 637D, 639D, 641B, 650B, 657B, 666B, 977K, D6C, D6D, D6E, D6G2 LGP, D6G2 XL, D7G, D7G2
572G, 621, 621B, 623, 623B, 627, 627B, 631C, 631D, 633D, 637, 637D, 639D, 641B, 650B, 657B, 666B, 977K, D6C, D6D, D6E, D6G2 LGP, D6G2 XL, D7G, D7G2
5M6211
SHAFT-PLANETARY
14E, 572G, 977K, D6C, D6D, D6E, D6G, D6G2 LGP, D6G2 XL, D7G, D7G2
14E, 572G, 977K, D6C, D6D, D6E, D6G, D6G2 LGP, D6G2 XL, D7G, D7G2
5S6116
SHAFT
14E, 941, 966C, 977K, D6C, D7F
14E, 941, 966C, 977K, D6C, D7F
4S8534
SHAFT ASSEM.
814, 815, 950, 955K, 955L, 966C, D5, D5B
814, 815, 950, 955K, 955L, 966C, D5, D5B
8H4714
SHAFT ASSEM.
D9E, D9G
D9E, D9G
4M0578
SHAFT
D9G, D9H
D9G, D9H
5M3999
SHAFT
594, 594H, D8H, D8K, D9G, D9H
594, 594H, D8H, D8K, D9G, D9H
3S1261
SHAFT
594, 594H, 657, D9G, D9H
594, 594H, 657, D9G, D9H
1M4167
SHAFT
594, 594H, D8H, D8K, D9G, D9H
594, 594H, D8H, D8K, D9G, D9H
5J5105
SHAFT
955K, 955L, 977K
955K, 955L, 977K
3S0726
SHAFT
583K, 594H, D8H, D9G
583K, 594H, D8H, D9G
9H8913
SHAFT
594H, 983, 983B, D8H, D9G
594H, 983, 983B, D8H, D9G
4M2296
SHAFT (LEFT HAND)
594H, D9G
594H, D9G
4M2297
SHAFT
594H, D9G
594H, D9G
9H0966
SHAFT
583H, 583K, 594H, D8H, D8K, D9G, D9H
583H, 583K, 594H, D8H, D8K, D9G, D9H
9H8823
SHAFT ASSEM.
583H, 583K, 594H, D8H, D8K, D9G, D9H
583H, 583K, 594H, D8H, D8K, D9G, D9H