3483435 SHAFT GP-DRIVE Caterpillar parts
924K, 930K
Rating:
Alternative (cross code) number:
CA3483435
348-3435
3483435
CA3483435
348-3435
3483435
WHEEL LOADER,
Information:
Throttle Lock Engine Set Speed Increment
The "Throttle Lock Engine Set Speed Increment" controls the increase in engine speed when the PTO switch is briefly operated to ACCELERATE or DECELERATE. If this parameter is set to "0", the feature is turned off.
Table 8
Minimum    Maximum    Default    
0 rpm     200 rpm     10 rpm    Miscellaneous
Monitoring Mode Shutdowns
"Monitoring Mode Shutdowns" controls the shutdown feature that is associated with the engine monitoring feature. When this feature is enabled and an event code with a "-3" suffix is detected, the engine will be shut down.
Table 9
Value    Default    
Disabled
Enabled     Disabled    Monitoring Mode Derates
"Monitoring Mode Derates" controls the derate that is associated with the engine monitoring feature. When this feature is enabled and an event code with a "-2" is detected, the engine will be derated.
Table 10
Value    Default    
Disabled
Enabled     Enabled    Limp Home Desired Engine Speed
The "Limp Home Desired Engine Speed" is the maximum speed of the engine when the engine has been derated.
Table 11
Minimum    Maximum    Default    
700 rpm     1800 rpm     1200 rpm    J1939 Continuous Fault Handling
Remote Torque Speed Control Enable Status
The "Remote Torque Speed Control Enable Status" parameter determines the way that faults will be handled by the ECM when the "J1939 Torque Speed Control (TSC1)" message is used as a speed request input to the ECM. Programming the "Remote Torque Speed Control Enable Status" to "Enabled" will cause the ECM to display a fault code if a valid TSC1 message is not received by the engine ECM within 30 seconds of the engine starting. If the" Remote Torque Speed Control Enable Status" is programmed to "Disabled", the engine will display a 247-12 Data Link Malfunction immediately after a loss of a TSC1 message. Program "Remote Torque Speed Control Enable Status" to "Enabled" if the ECM will always be receiving a TSC1 message.
Table 12
Value    Default    
Disabled
Enabled     Disabled    Configurable Inputs
Coolant Level Sensor
A coolant level sensor is an optional switch input. Programming the "Coolant Level Sensor" parameter to "Enabled" notifies the ECM that a coolant level sensor input is present. If this parameter is programmed
The "Throttle Lock Engine Set Speed Increment" controls the increase in engine speed when the PTO switch is briefly operated to ACCELERATE or DECELERATE. If this parameter is set to "0", the feature is turned off.
Table 8
Minimum    Maximum    Default    
0 rpm     200 rpm     10 rpm    Miscellaneous
Monitoring Mode Shutdowns
"Monitoring Mode Shutdowns" controls the shutdown feature that is associated with the engine monitoring feature. When this feature is enabled and an event code with a "-3" suffix is detected, the engine will be shut down.
Table 9
Value    Default    
Disabled
Enabled     Disabled    Monitoring Mode Derates
"Monitoring Mode Derates" controls the derate that is associated with the engine monitoring feature. When this feature is enabled and an event code with a "-2" is detected, the engine will be derated.
Table 10
Value    Default    
Disabled
Enabled     Enabled    Limp Home Desired Engine Speed
The "Limp Home Desired Engine Speed" is the maximum speed of the engine when the engine has been derated.
Table 11
Minimum    Maximum    Default    
700 rpm     1800 rpm     1200 rpm    J1939 Continuous Fault Handling
Remote Torque Speed Control Enable Status
The "Remote Torque Speed Control Enable Status" parameter determines the way that faults will be handled by the ECM when the "J1939 Torque Speed Control (TSC1)" message is used as a speed request input to the ECM. Programming the "Remote Torque Speed Control Enable Status" to "Enabled" will cause the ECM to display a fault code if a valid TSC1 message is not received by the engine ECM within 30 seconds of the engine starting. If the" Remote Torque Speed Control Enable Status" is programmed to "Disabled", the engine will display a 247-12 Data Link Malfunction immediately after a loss of a TSC1 message. Program "Remote Torque Speed Control Enable Status" to "Enabled" if the ECM will always be receiving a TSC1 message.
Table 12
Value    Default    
Disabled
Enabled     Disabled    Configurable Inputs
Coolant Level Sensor
A coolant level sensor is an optional switch input. Programming the "Coolant Level Sensor" parameter to "Enabled" notifies the ECM that a coolant level sensor input is present. If this parameter is programmed
Caterpillar SIS machinery equipment:
Caterpillar SIS
924K Wheel Loader PWR00001-UP (MACHINE) POWERED BY C6.6 Engine »
348-3435
SHAFT GP-DRIVE
930K Wheel Loader RHN00001-UP (MACHINE) POWERED BY C6.6 Engine »
348-3435
SHAFT GP-DRIVE
924K Small Wheel Loader ENC00001-UP (MACHINE) POWERED BY C7.1 Engine »
348-3435
SHAFT GP-DRIVE
924K Small Wheel Loader HJF00001-UP (MACHINE) POWERED BY C7.1 Engine »
348-3435
SHAFT GP-DRIVE
930K Small Wheel Loader DYB00001-UP (MACHINE) POWERED BY C7.1 Engine »
348-3435
SHAFT GP-DRIVE
930K Small Wheel Loader EYE00001-UP (MACHINE) POWERED BY C7.1 Engine »
348-3435
SHAFT GP-DRIVE
Caterpillar parts catalog:
Parts shaft Caterpillar catalog:
8R2200
SHAFT-PLANETARY
928F, 928G, 928H, 928HZ, 930G, 930K, IT18F, IT28F, IT28G
928F, 928G, 928H, 928HZ, 930G, 930K, IT18F, IT28F, IT28G
8R0248
SHAFT-PLANETARY
918F, 924F, 924G, 924GZ, 924H, 924HZ, 924K, IT12B, IT18F, IT24F
918F, 924F, 924G, 924GZ, 924H, 924HZ, 924K, IT12B, IT18F, IT24F
3548645
SHAFT
924K, 930K, 938K
924K, 930K, 938K
3391873
SHAFT GP-INPUT
924K, 930K, 938K
924K, 930K, 938K
3370298
SHAFT
924K, 930K, 938K
924K, 930K, 938K
3391942
SHAFT GP-INPUT
924K, 930K, 938K
924K, 930K, 938K
3478322
SHAFT
924K, 930K, 938K
924K, 930K, 938K
3782829
SHAFT
924K
924K
3452751
SHAFT
924K, 930K, 938K
924K, 930K, 938K
3782808
SHAFT
930K, 938K
930K, 938K
3476229
SHAFT AS
924H, 930K
924H, 930K
4523028
SHAFT
930K
930K
2969358
SHAFT GP-VIBRATORY
AP-600D, AP-655D, AP555E, AS4251C
AP-600D, AP-655D, AP555E, AS4251C
1005926
SHAFT GP-DRIVE
938F, 938G, IT38F, IT38G
938F, 938G, IT38F, IT38G
2807008
SHAFT GP-OUTPUT
434E, 434F, 444E, 444F
434E, 434F, 444E, 444F
1975004
SHAFT GP-OUTPUT
M325B
M325B
2655695
SHAFT GP-TRANSMISSION
TA22-M4WD
TA22-M4WD
3558966
SHAFT GP-ECCENTRIC WEIGHT
CP-74B, CS-74B, CS-76B, CS-78B
CP-74B, CS-74B, CS-76B, CS-78B
2659249
SHAFT GP-DRIVE
M315D, M317D 2
M315D, M317D 2
2708684
SHAFT GP-DRIVE
CB-434D
CB-434D