Procedure For Programming The Hour meter
This procedure uses a new GSC with 0 hours as an example. The hour meter in the new GSC will be set to a value of 1,234 hours. The value must be higher than the original value. Note: Service mode cannot be entered when the ECS is in the AUTO position. Note: Any active shutdown fault must be made inactive in order to access service mode. A FLASHING shutdown indicator means that a shutdown fault exists. To temporarily change a shutdown fault from an active shutdown fault to an inactive shutdown fault, turn the ECS to the OFF/RESET position. To permanently change a shutdown fault from an active shutdown fault to an inactive shutdown fault, the fault must not be occurring. Also, the ECS must be turned to the OFF/RESET position. If the jumper from terminal 6 to terminal 9 is not installed on the ECS, then the GSC will not power up in OFF/RESET and any active shutdown fault must be corrected before entering service mode.
Turn the ECS to the STOP position in order to shut down the engine. Enter service mode and enter the password. "OP 1" is showing on lower display. See Systems Operation, "Service Mode" for more information. See Systems Operation, "Password Entry OP3" for more information.
Press "SCROLL UP" key six times. "OP 7" is showing on the lower display.
Press "SELECT" key. The present value for the hour meter is showing.
. Press "SELECT" key. "000000" is showing and the first digit is flashing.
Press "SCROLL RIGHT" key two times. "000000" is showing and the third digit is flashing.
Press "SCROLL UP" key. "001000" is showing and the third digit is flashing.
Press "SCROLL RIGHT" key. "001000" is showing and the fourth digit is flashing.
. Press "SCROLL UP" key two times. "001200" is showing and the fourth digit is flashing.
Press "SCROLL RIGHT" key. "001200" is showing and the fifth digit is flashing.
Press "SCROLL UP" key three times. "001230" is showing and the fifth digit is flashing.
Press "SCROLL RIGHT" key. "001230" is showing and the sixth digit is flashing.
Press "SCROLL UP" key four times. "001234" is showing and the sixth digit is flashing.
Press "ENTER" key. "001234" flashes on the lower display and "ArE YOU SUrE" is showing on the upper display.
For "yes", press "ENTER" key. "001234" stops flashing.
For "no", press "SELECT" key. "000000" is showing and the first digit is flashing. Repeat this procedure to program the hour meter again.Note: In order to exit this procedure without saving any changes, press the exit key twice when the display shows "ArE YOU SUrE". The GSC returns to the normal display. The original value for the hour meter is kept in the memory of the GSC. Note: Lower hours cannot be entered into the GSC if the GSC has a value that is stored. the upper display briefly shows "Error". The display then shows the original hours that are stored in the GSC and the first digit is flashing.
Press "EXIT" key. "OP 1" is showing on
This procedure uses a new GSC with 0 hours as an example. The hour meter in the new GSC will be set to a value of 1,234 hours. The value must be higher than the original value. Note: Service mode cannot be entered when the ECS is in the AUTO position. Note: Any active shutdown fault must be made inactive in order to access service mode. A FLASHING shutdown indicator means that a shutdown fault exists. To temporarily change a shutdown fault from an active shutdown fault to an inactive shutdown fault, turn the ECS to the OFF/RESET position. To permanently change a shutdown fault from an active shutdown fault to an inactive shutdown fault, the fault must not be occurring. Also, the ECS must be turned to the OFF/RESET position. If the jumper from terminal 6 to terminal 9 is not installed on the ECS, then the GSC will not power up in OFF/RESET and any active shutdown fault must be corrected before entering service mode.
Turn the ECS to the STOP position in order to shut down the engine. Enter service mode and enter the password. "OP 1" is showing on lower display. See Systems Operation, "Service Mode" for more information. See Systems Operation, "Password Entry OP3" for more information.
Press "SCROLL UP" key six times. "OP 7" is showing on the lower display.
Press "SELECT" key. The present value for the hour meter is showing.
. Press "SELECT" key. "000000" is showing and the first digit is flashing.
Press "SCROLL RIGHT" key two times. "000000" is showing and the third digit is flashing.
Press "SCROLL UP" key. "001000" is showing and the third digit is flashing.
Press "SCROLL RIGHT" key. "001000" is showing and the fourth digit is flashing.
. Press "SCROLL UP" key two times. "001200" is showing and the fourth digit is flashing.
Press "SCROLL RIGHT" key. "001200" is showing and the fifth digit is flashing.
Press "SCROLL UP" key three times. "001230" is showing and the fifth digit is flashing.
Press "SCROLL RIGHT" key. "001230" is showing and the sixth digit is flashing.
Press "SCROLL UP" key four times. "001234" is showing and the sixth digit is flashing.
Press "ENTER" key. "001234" flashes on the lower display and "ArE YOU SUrE" is showing on the upper display.
For "yes", press "ENTER" key. "001234" stops flashing.
For "no", press "SELECT" key. "000000" is showing and the first digit is flashing. Repeat this procedure to program the hour meter again.Note: In order to exit this procedure without saving any changes, press the exit key twice when the display shows "ArE YOU SUrE". The GSC returns to the normal display. The original value for the hour meter is kept in the memory of the GSC. Note: Lower hours cannot be entered into the GSC if the GSC has a value that is stored. the upper display briefly shows "Error". The display then shows the original hours that are stored in the GSC and the first digit is flashing.
Press "EXIT" key. "OP 1" is showing on
Caterpillar parts catalog:
Parts shaft Caterpillar catalog:
5493962
SHAFT
Caterpillar
Caterpillar
5433710
SHAFT-REAR
Caterpillar
Caterpillar
5433709
SHAFT-FRONT
Caterpillar
Caterpillar
5433689
SHAFT & CPLG GP-PISTON PUMP
Caterpillar
Caterpillar
5269279
SHAFT-TRACK IDLER
Caterpillar
Caterpillar
5232220
SHAFT-TRACK ROLLER
Caterpillar
Caterpillar
3581208
SHAFT-AXLE
Caterpillar
Caterpillar
3260755
SHAFT AS
Caterpillar
Caterpillar
2861689
SHAFT
Caterpillar
Caterpillar
5516797
SHAFT-DRIVE
Caterpillar
Caterpillar
5516796
SHAFT-DRIVE
Caterpillar
Caterpillar
5505782
SHAFT AS-MOTOR
Caterpillar
Caterpillar