7N5899 SHAFT-WATER PUMP Caterpillar parts
120G, 140B, 1673C, 235, 3304, 3306, 3306B, 528, 814, 815B, 920, 930, 941, 955L, 966C, D4E, D5B, D7G, G3304, G3306
Rating:
Alternative (cross code) number:
CA7N5899
7N-5899
7N5899
CA7N5899
7N-5899
7N5899
Weight: 0.54 pounds 0 kg.
ENGINE - MACHINE, WHEEL SKIDDER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$19.05
19 Dec 2023
US: Florida-Parts-Z
1725189 - IMPELLER-PUMP 1725185 2W7255 7N5899 1558758 for Caterpillar (CAT)
FIRST PRICE PARTS
FIRST PRICE PARTS
$19.56
09 Oct 2023
US: Florida-Parts-Z
2W7255 - SHAFT-WATER PUMP 1725185 1725189 1490791 7N5899 for Caterpillar (CAT)
FIRST PRICE PARTS
FIRST PRICE PARTS
$8.76
28 Nov 2022
Amazon.com
CTP 7N5899 Caterpillar Water Pump Shaft for Model D342
CTP All impellers are balanced to improve pump performance and reduce vibration || All internal components are made to specifications to ensure CTP Components fit properly || Come with a stainless steel shaft to increase the longevity of the pump, while competitors use a carbon steel shaft
CTP All impellers are balanced to improve pump performance and reduce vibration || All internal components are made to specifications to ensure CTP Components fit properly || Come with a stainless steel shaft to increase the longevity of the pump, while competitors use a carbon steel shaft
Compatible equipment models: 7N5899:
Information:
Note: Power factor (PF) regulation is an optional feature.Parameters that are related to PF regulation are listed below.:01 - Generator Output Voltage:02 - Ratio of Output Voltage to Sensing Voltage:03 - Generator Type:04 - Rated Generator Output Current:05 - CT Voltage at Rated Generator Current:31 - PF/KVAR Select:32 - PF Reference:33 - KVAR Reference:36 - Paralleling Integral Gain:37 - Paralleling Proportional Gain:38 - PF Switch PointNote: Parameters :36, :37 and :38 are only available on part number 155-xxxx or newer.If a generator is connected in parallel with an infinite bus (utility), then the voltage of the generator is controlled by the infinite bus. The voltage of the generator will change as the infinite bus voltage changes. It is not possible to control the system voltage when the generator is connected to an infinite bus. In this instance, it is necessary for the digital voltage regulator to regulate the reactive power output which is supplied by the generator. There are two methods for regulating the reactive power output.
KVAR Regulation
Power Factor RegulationNote: KVAR stands for kilo-Volt-Ampere-Reactive, which is the unit of measurement for reactive power.If the digital voltage regulator is in the power factor operating mode, then it regulates so that the generator produces a constant power factor, regardless of the real power output of the generator. In this case, the reactive current will change when the real power output of the generator changes. A current transformer (CT) is necessary for this mode to work.Operation of the power factor mode has changed a number of times. The power factor mode has changed in order to improve the behavior at low levels of real current. The first change took place when the "PROM ID" (parameter :91) changed to 1.03. The "PROM ID" change coincided with the new fault parameter methods. The second change took place when the part number for the regulator changed to 155-xxxx and the "PROM ID" changed to 1.05.Original Power Factor Operation
If parameter :31 is set to zero, and the external switch on terminal 41 is closed, then the regulator will operate in "power factor control mode". The regulator assumes the generator is connected to an infinite bus, therefore, the voltage cannot be changed. In power factor mode the generator will supply a varying amount of reactive power (KVARs) based upon the real power output (kW) of the generator to obtain the desired power factor set in parameter :32 (or a remote rheostat).PROM ID 1.03 Power Factor Operation
If parameter :31 is set to zero, and the external switch on terminal 41 is closed, then the regulator will start-up in the KVAR mode supplying 0 KVAR. When the real current measurement is equal to or above 10% of the rated generator output current, the regulator will switch operation to the power factor control mode. The rated generator output current is parameter :04. Thus, the generator set needs to provide a significant amount of real kW power before the digital voltage regulator will regulate in the power factor mode. The
KVAR Regulation
Power Factor RegulationNote: KVAR stands for kilo-Volt-Ampere-Reactive, which is the unit of measurement for reactive power.If the digital voltage regulator is in the power factor operating mode, then it regulates so that the generator produces a constant power factor, regardless of the real power output of the generator. In this case, the reactive current will change when the real power output of the generator changes. A current transformer (CT) is necessary for this mode to work.Operation of the power factor mode has changed a number of times. The power factor mode has changed in order to improve the behavior at low levels of real current. The first change took place when the "PROM ID" (parameter :91) changed to 1.03. The "PROM ID" change coincided with the new fault parameter methods. The second change took place when the part number for the regulator changed to 155-xxxx and the "PROM ID" changed to 1.05.Original Power Factor Operation
If parameter :31 is set to zero, and the external switch on terminal 41 is closed, then the regulator will operate in "power factor control mode". The regulator assumes the generator is connected to an infinite bus, therefore, the voltage cannot be changed. In power factor mode the generator will supply a varying amount of reactive power (KVARs) based upon the real power output (kW) of the generator to obtain the desired power factor set in parameter :32 (or a remote rheostat).PROM ID 1.03 Power Factor Operation
If parameter :31 is set to zero, and the external switch on terminal 41 is closed, then the regulator will start-up in the KVAR mode supplying 0 KVAR. When the real current measurement is equal to or above 10% of the rated generator output current, the regulator will switch operation to the power factor control mode. The rated generator output current is parameter :04. Thus, the generator set needs to provide a significant amount of real kW power before the digital voltage regulator will regulate in the power factor mode. The
Cat SIS web machinery list:
Parts shaft Caterpillar catalog:
2D8764
SHAFT
12E, 140B, 14E
12E, 140B, 14E
2Y2158
SHAFT
120B, 140B
120B, 140B
2Y1993
SHAFT
120B, 140B
120B, 140B
7D6524
SHAFT
120B, 12F, 140B, 14E
120B, 12F, 140B, 14E
8D0682
SHAFT
120, 120B, 140, 140B
120, 120B, 140, 140B
6F1752
SHAFT
120B, 12E, 140, 140B
120B, 12E, 140, 140B
6F1751
SHAFT
120B, 12E, 140, 140B
120B, 12E, 140, 140B
7D1846
SHAFT ASSEM.
120B, 140, 140B
120B, 140, 140B
4D5448
SHAFT ASSEM.
120B, 12E, 140B
120B, 12E, 140B
8J6296
SHAFT
120G, 12G, 130G
120G, 12G, 130G
2G9853
SHAFT
120B, 140B
120B, 140B
7D5446
SHAFT
140B
140B
6N0591
SHAFT
3304, 3306, 3306B, 3406C, 627B, 637D, D6C
3304, 3306, 3306B, 3406C, 627B, 637D, D6C
0676929
SHAFT
206, 212, 312, 315, 317, 428B, RT50
206, 212, 312, 315, 317, 428B, RT50
4550726
SHAFT
424B HD
424B HD
4543205
SHAFT-PUMP
424B
424B
3808840
SHAFT
424B
424B
3837987
SHAFT-OUTPUT
424B
424B
9R0535
SHAFT AS
426, 428
426, 428
9R0981
SHAFT
428
428
9R0915
SHAFT AS
416, 428, 438
416, 428, 438
9R1676
SHAFT
426, 428
426, 428
3S4125
SHAFT
3304, 3306, 815, 963, 966C, 973, 980B, D6C, R1300, R1300G
3304, 3306, 815, 963, 966C, 973, 980B, D6C, R1300, R1300G
9R2408
SHAFT AS
426
426