8E9567 SHAFT AS-INPUT Caterpillar parts
D5H, D5M, D6M
Rating:
Alternative (cross code) number:
CA8E9567
8E-9567
8E9567
CA8E9567
8E-9567
8E9567
Weight: 22 pounds 10 kg.
TRACK-TYPE TRACTOR,
Information:
If the trip point for a shutdown is programmed to activate before the trip point for a warning, the engine will shut down and the warning will not be activated.Integrated Sensing Module (ISM)
The ISM monitors the temperatures of the cylinder exhaust ports, the inlets of the turbocharger turbine, and the outlets of the turbocharger turbines. The ISM also monitors the combustion sensors.If a temperature exceeds an acceptable range, the ISM can initiate a warning or a shutdown. Both of the responses are available for all of the parameters.Note: To initiate the responses, the ISM sends commands to the ECM via the Cat Data Link.The default settings for the parameters are programmed at the factory. To accommodate unique applications and sites, the parameters may be reprogrammed with Cat ET. The screens of Cat ET provide guidance for changing trip points. Use Cat ET to perform the following activities:
Select the available responses.
Program the level for monitoring.
Program delay times for each response.Table 4 lists default examples of the values for the parameters. However, the values may have changed. Use Cat ET to determine the programming for your engine.
Table 4
Default Settings of the Integrated Sensing Module
Parameter Action Default State Security Level
Password Trip Point Range Delay in Seconds Range of the Delay in Seconds
1184–15 High Left Turbo Turbine Outlet Temperature (1)
Warning On Customer 570 °C (1058 °F) 400 to 650 °C (752 to 1202 °F) 10 1 to 1200
1184–0 High Left Turbo Turbine Outlet Temperature (3)
Shutdown 600 °C (1112 °F)
1185–0 High Right Turbo Turbine Outlet Temperature (1)
Warning On Customer 570 °C (1058 °F) 400 to 650 °C (752 to 1202 °F) 10 1 to 1200
1185–0 High Right Turbo Turbine Outlet Temperature (3)
Shutdown 600 °C (1112 °F)
1181–15 High Right Turbo Turbine Inlet Temperature (1)
Warning On Customer 600 °C (1112 °F) 400 to 700 °C (752 to 1292 °F) 10 1 to 1200
1181–0 High Right Turbo Turbine Inlet Temperature (3)
Shutdown 650 °C (1202 °F)
1180–15 High Left Turbo Turbine Inlet Temperature (1)
Warning On Customer 600 °C (1112 °F) 400 to 700 °C (752 to 1292 °F) 10 1 to 1200
1180–0 High Left Turbo Turbine Inlet Temperature (3)
Shutdown 650 °C (1202 °F)
1137-15 through 1151-15 Cylinder High Exhaust Port Temp 15
Warning Off Customer 600 °C (1112 °F) 100 to 1000 °C (212 to 1832 °F) 10 1 to 1200
1137-0 through 1151-0 Cylinder High Exhaust Port Temp 0
Shutdown 650 °C (1202 °F)
5686-15 through 5701-15 Exhaust Port Temp Deviating High (1)
Warning On Customer 50 °C (90 °F) 10 to 500 °C (18 to 900 °F) 240 1 to 1200
5686-0 through 5701-0 Exhaust Port Temp Deviating High (3)
Shutdown Off 100 °C (180 °F) 600
5686-17 through 5701-17 Exhaust Port Temp Deviating Low (1)
Warning On Customer 120 °C (216 °F) 10 to 500 °C (18 to 900 °F) 300 1 to 1200
5686-1 through 5701-1 Exhaust Port Temp Deviating Low (3)
Shutdown Off 400 °C (720 °F)
The ISM monitors the temperatures of the cylinder exhaust ports, the inlets of the turbocharger turbine, and the outlets of the turbocharger turbines. The ISM also monitors the combustion sensors.If a temperature exceeds an acceptable range, the ISM can initiate a warning or a shutdown. Both of the responses are available for all of the parameters.Note: To initiate the responses, the ISM sends commands to the ECM via the Cat Data Link.The default settings for the parameters are programmed at the factory. To accommodate unique applications and sites, the parameters may be reprogrammed with Cat ET. The screens of Cat ET provide guidance for changing trip points. Use Cat ET to perform the following activities:
Select the available responses.
Program the level for monitoring.
Program delay times for each response.Table 4 lists default examples of the values for the parameters. However, the values may have changed. Use Cat ET to determine the programming for your engine.
Table 4
Default Settings of the Integrated Sensing Module
Parameter Action Default State Security Level
Password Trip Point Range Delay in Seconds Range of the Delay in Seconds
1184–15 High Left Turbo Turbine Outlet Temperature (1)
Warning On Customer 570 °C (1058 °F) 400 to 650 °C (752 to 1202 °F) 10 1 to 1200
1184–0 High Left Turbo Turbine Outlet Temperature (3)
Shutdown 600 °C (1112 °F)
1185–0 High Right Turbo Turbine Outlet Temperature (1)
Warning On Customer 570 °C (1058 °F) 400 to 650 °C (752 to 1202 °F) 10 1 to 1200
1185–0 High Right Turbo Turbine Outlet Temperature (3)
Shutdown 600 °C (1112 °F)
1181–15 High Right Turbo Turbine Inlet Temperature (1)
Warning On Customer 600 °C (1112 °F) 400 to 700 °C (752 to 1292 °F) 10 1 to 1200
1181–0 High Right Turbo Turbine Inlet Temperature (3)
Shutdown 650 °C (1202 °F)
1180–15 High Left Turbo Turbine Inlet Temperature (1)
Warning On Customer 600 °C (1112 °F) 400 to 700 °C (752 to 1292 °F) 10 1 to 1200
1180–0 High Left Turbo Turbine Inlet Temperature (3)
Shutdown 650 °C (1202 °F)
1137-15 through 1151-15 Cylinder High Exhaust Port Temp 15
Warning Off Customer 600 °C (1112 °F) 100 to 1000 °C (212 to 1832 °F) 10 1 to 1200
1137-0 through 1151-0 Cylinder High Exhaust Port Temp 0
Shutdown 650 °C (1202 °F)
5686-15 through 5701-15 Exhaust Port Temp Deviating High (1)
Warning On Customer 50 °C (90 °F) 10 to 500 °C (18 to 900 °F) 240 1 to 1200
5686-0 through 5701-0 Exhaust Port Temp Deviating High (3)
Shutdown Off 100 °C (180 °F) 600
5686-17 through 5701-17 Exhaust Port Temp Deviating Low (1)
Warning On Customer 120 °C (216 °F) 10 to 500 °C (18 to 900 °F) 300 1 to 1200
5686-1 through 5701-1 Exhaust Port Temp Deviating Low (3)
Shutdown Off 400 °C (720 °F)
Caterpillar parts catalog:
Parts shaft Caterpillar catalog:
8G5798
SHAFT AS
D5H
D5H
1318742
SHAFT-TRACK ROLLER
517, 953C, D5H, D5H XL, D5HTSK II, D6M, D6N, OEMS
517, 953C, D5H, D5H XL, D5HTSK II, D6M, D6N, OEMS
6E6572
SHAFT
527, D5H, D5H XL, D5HTSK II, D6M
527, D5H, D5H XL, D5HTSK II, D6M
6T2620
SHAFT-TRACK IDLER
561M, D4H, D4H XL, D4HTSK II, D4HTSK III, D5M, PM-565, PM-565B
561M, D4H, D4H XL, D4HTSK II, D4HTSK III, D5M, PM-565, PM-565B
9T3932
SHAFT
D4H, D4H XL, D4HTSK II, D4HTSK III, D5M
D4H, D4H XL, D4HTSK II, D4HTSK III, D5M
1060714
SHAFT
D6M
D6M
1796707
SHAFT
D5R LGP, D6K LGP, D6K2, D6K2 LGP, D6M, D6N, D6N LGP, D6N OEM, PL61
D5R LGP, D6K LGP, D6K2, D6K2 LGP, D6M, D6N, D6N LGP, D6N OEM, PL61
1617350
SHAFT-TRACK IDLER
D5R LGP, D6M, D6N, D6N LGP, D6N OEM
D5R LGP, D6M, D6N, D6N LGP, D6N OEM
1080803
SHAFT AS
D5R LGP, D6M, D6N, D6N LGP, OEMS
D5R LGP, D6M, D6N, D6N LGP, OEMS
1080850
SHAFT AS
D5R LGP, D6M, D6N, D6N LGP, D6N OEM, OEMS
D5R LGP, D6M, D6N, D6N LGP, D6N OEM, OEMS
1096772
SHAFT AS
D5M, D5N
D5M, D5N
1108384
SHAFT
561M, 572R, D5M, D6M, D6R, D7R
561M, 572R, D5M, D6M, D6R, D7R
1453852
SHAFT
D5M, D6M, D6R, D7R
D5M, D6M, D6R, D7R
1108383
SHAFT
561M, 572R, D5M, D6M, D6R, D7R
561M, 572R, D5M, D6M, D6R, D7R
1210487
SHAFT AS
D6M, D6N
D6M, D6N
1533797
SHAFT
561M, D5M, D6M
561M, D5M, D6M
1152954
SHAFT
561M, D5M, D6M
561M, D5M, D6M
1688936
SHAFT
D6R, D7R
D6R, D7R
8E2881
SHAFT
D5M, D6M, D9R
D5M, D6M, D9R
1330155
SHAFT
561N, 572R II, 587T, D10R, D10T, D10T2, D11R, D11T, D5M, D5N, D6M, D6N, D6R, D6R II, D7R, D7R II, PL87
561N, 572R II, 587T, D10R, D10T, D10T2, D11R, D11T, D5M, D5N, D6M, D6N, D6R, D6R II, D7R, D7R II, PL87
1300701
SHAFT
561N, 572R II, 587T, D10R, D10T, D10T2, D11R, D11T, D5M, D5N, D6M, D6N, D6R, D6R II, D7R, D7R II, PL87
561N, 572R II, 587T, D10R, D10T, D10T2, D11R, D11T, D5M, D5N, D6M, D6N, D6R, D6R II, D7R, D7R II, PL87
1337230
SHAFT
561N, 572R, 572R II, 587T, D10R, D10T, D10T2, D11R, D11T, D5M, D5N, D6M, D6N, D6R, D6R II, D7R, D7R II, PL87
561N, 572R, 572R II, 587T, D10R, D10T, D10T2, D11R, D11T, D5M, D5N, D6M, D6N, D6R, D6R II, D7R, D7R II, PL87
1337214
SHAFT
561N, 572R, 572R II, 587T, D10R, D10T, D10T2, D11R, D11T, D5M, D5N, D6M, D6N, D6R, D6R II, D7R, D7R II, PL87
561N, 572R, 572R II, 587T, D10R, D10T, D10T2, D11R, D11T, D5M, D5N, D6M, D6N, D6R, D6R II, D7R, D7R II, PL87