9W2143 SHAFT-TRACK ROLLER Caterpillar parts
205B, 211B, 215B, 215D
Rating:
Alternative (cross code) number:
CA9W2143
9W-2143
9W2143
CA9W2143
9W-2143
9W2143
Weight: 22 pounds 10 kg.
EXCAVATOR,
Information:
The components of the switchgear are contained in two cabinets. All operational interface functions for the genset are performed by the devices that are located on the doors of the right cabinet. The general layout and general component locations are shown in illustration 1.The panel for wiring connections for the power module (2) contains the following items:
Wiring connections for the power module
Circuit breakers for the distribution of AC power
Switches for AC
Circuit breakers for the distribution of DC power
Switches for DC
Battery charger
Distribution relays for the source selective power
Control circuit for the louver assembly (optional equipment)
Heater for the compartmentThe panel for the touchscreen display and controls (3) contains the following items:
Touchscreen display
Engine controls
Generator controls
Annunciator
Paralleling controls
Loading controls
Wiring connections for control by the customer
Illustration 2 g00842685
Rear View (8) Connections for the fan motor (factory connections) (9) Transformer for power distribution (37.5 kVA, 480:240/120 ACV secondary) (10) Connections for the generator (factory connections) (11) Transformer for ground current (12) Neutral for the system (13) Connections for the load (customer connections)Illustration 2 shows the locations of the components that are accessible from the back of the cabinet. Access to the rear components is through the exterior bus access doors of the power module and removable panels of the switchgear. For clarity, the panels have been removed.
Illustration 3 g00853335
Detail of the Rear View (10) Connections for the generator (factory connections) (11) Transformer for ground current (12) Neutral for the system (13) Connections for the Load (customer connections)The panels must be replaced before you energize the utility bus. The panels must be replaced before you energize the bus for the generator.Medium Voltage Switchgear
Illustration 4 g00842681
Front View (14) Door for the radiator fan contactor (15) Panel for touchscreen display and controls (16) Compartment for the generator circuit breaker (17) Panel for relays and power distributionThe components of the switchgear are contained in two cabinets. All operational interface functions for the genset are performed by the devices that are located on the doors of the right cabinet. The general layout and general component locations are shown in illustration 4.The contactor for the circuit for the fan motor is rated at 5 kV. The door for the radiator fan contactor (14) is electrically interlocked. When the door for the radiator fan contactor (14) is opened, the generator circuit breaker is tripped and the genset is shut down.The panel for touchscreen display and controls (15) contains the following items:
Touchscreen display
Engine controls
Generator controls
Annunciator
Paralleling controls
Loading controls
Wiring connections for control by the customer
Wiring connections for the power moduleA heater for the compartment is provided.The panel for relays and power distribution (17) contains the following items:
Generator multifunction relay (GMR)
Utility multifunction relay (UMR)
Generator differential relay (optional equipment)
Circuit breakers for power distribution
Distribution relays for source selective power
Control circuit for the louver assembly (optional equipment)
Battery charger
Drawout fuses
Main distribution breaker
Fuses The fuses are used with the secondary winding of the potential transformer. These fuses are for the utility bus.The compartment for the generator circuit breaker (16) contains a drawout generator circuit breaker that is rated at 5 kV. A heater is
Wiring connections for the power module
Circuit breakers for the distribution of AC power
Switches for AC
Circuit breakers for the distribution of DC power
Switches for DC
Battery charger
Distribution relays for the source selective power
Control circuit for the louver assembly (optional equipment)
Heater for the compartmentThe panel for the touchscreen display and controls (3) contains the following items:
Touchscreen display
Engine controls
Generator controls
Annunciator
Paralleling controls
Loading controls
Wiring connections for control by the customer
Illustration 2 g00842685
Rear View (8) Connections for the fan motor (factory connections) (9) Transformer for power distribution (37.5 kVA, 480:240/120 ACV secondary) (10) Connections for the generator (factory connections) (11) Transformer for ground current (12) Neutral for the system (13) Connections for the load (customer connections)Illustration 2 shows the locations of the components that are accessible from the back of the cabinet. Access to the rear components is through the exterior bus access doors of the power module and removable panels of the switchgear. For clarity, the panels have been removed.
Illustration 3 g00853335
Detail of the Rear View (10) Connections for the generator (factory connections) (11) Transformer for ground current (12) Neutral for the system (13) Connections for the Load (customer connections)The panels must be replaced before you energize the utility bus. The panels must be replaced before you energize the bus for the generator.Medium Voltage Switchgear
Illustration 4 g00842681
Front View (14) Door for the radiator fan contactor (15) Panel for touchscreen display and controls (16) Compartment for the generator circuit breaker (17) Panel for relays and power distributionThe components of the switchgear are contained in two cabinets. All operational interface functions for the genset are performed by the devices that are located on the doors of the right cabinet. The general layout and general component locations are shown in illustration 4.The contactor for the circuit for the fan motor is rated at 5 kV. The door for the radiator fan contactor (14) is electrically interlocked. When the door for the radiator fan contactor (14) is opened, the generator circuit breaker is tripped and the genset is shut down.The panel for touchscreen display and controls (15) contains the following items:
Touchscreen display
Engine controls
Generator controls
Annunciator
Paralleling controls
Loading controls
Wiring connections for control by the customer
Wiring connections for the power moduleA heater for the compartment is provided.The panel for relays and power distribution (17) contains the following items:
Generator multifunction relay (GMR)
Utility multifunction relay (UMR)
Generator differential relay (optional equipment)
Circuit breakers for power distribution
Distribution relays for source selective power
Control circuit for the louver assembly (optional equipment)
Battery charger
Drawout fuses
Main distribution breaker
Fuses The fuses are used with the secondary winding of the potential transformer. These fuses are for the utility bus.The compartment for the generator circuit breaker (16) contains a drawout generator circuit breaker that is rated at 5 kV. A heater is
Caterpillar parts catalog:
Parts shaft Caterpillar catalog:
9T4221
SHAFT GP
215B, 215C, 215D, 219D, 225, 225D, 229, 229D, 231D
215B, 215C, 215D, 219D, 225, 225D, 229, 229D, 231D
2W8087
SHAFT AS
120H, 120H ES, 120H NA, 135H, 135H NA, 205B, 214B, 30/30, 3114, 3116, 3126, 320 L, 320B, 322B L, 322B LN, 325, 325B, 325B L, 446B, 446D, 45, 55, 561M, 613C II, 918F, 924F, 928G, 938F, 938G, 950F, 950F...
120H, 120H ES, 120H NA, 135H, 135H NA, 205B, 214B, 30/30, 3114, 3116, 3126, 320 L, 320B, 322B L, 322B LN, 325, 325B, 325B L, 446B, 446D, 45, 55, 561M, 613C II, 918F, 924F, 928G, 938F, 938G, 950F, 950F...
2W8090
SHAFT AS-IDLER
120H, 120H ES, 120H NA, 135H, 135H NA, 205B, 214B, 30/30, 3114, 3116, 3126, 320 L, 320B, 322B L, 322B LN, 325, 325B, 325B L, 446B, 446D, 45, 55, 561M, 613C II, 918F, 924F, 928G, 938F, 938G, 950F, 950F...
120H, 120H ES, 120H NA, 135H, 135H NA, 205B, 214B, 30/30, 3114, 3116, 3126, 320 L, 320B, 322B L, 322B LN, 325, 325B, 325B L, 446B, 446D, 45, 55, 561M, 613C II, 918F, 924F, 928G, 938F, 938G, 950F, 950F...
4P3538
SHAFT-THROTTLE
120H, 120H ES, 120H NA, 135H, 135H NA, 206B, 211B, 213B, 214B, 3114, 3116, 3126, 320B, 322B L, 322B LN, 322C, 322C FM, 325, 325B, 325B L, 35, 446B, 446D, 45, 525B, 533, 535B, 539, 543, 55, 550, 561M, ...
120H, 120H ES, 120H NA, 135H, 135H NA, 206B, 211B, 213B, 214B, 3114, 3116, 3126, 320B, 322B L, 322B LN, 322C, 322C FM, 325, 325B, 325B L, 35, 446B, 446D, 45, 525B, 533, 535B, 539, 543, 55, 550, 561M, ...
8N3088
SHAFT AS-THROTTLE
120G, 12G, 12H, 12H ES, 12H NA, 130G, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 215, 215B, 225, 229, 229D, 235, 235B, 235C, 235D, 3204, 330, 330 FM L, 330...
120G, 12G, 12H, 12H ES, 12H NA, 130G, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 215, 215B, 225, 229, 229D, 235, 235B, 235C, 235D, 3204, 330, 330 FM L, 330...
1W2871
SHAFT AS-BALANCE
120G, 130G, 215B, 225, 3304B
120G, 130G, 215B, 225, 3304B
1W2870
SHAFT AS-BALANCE
120G, 130G, 215B, 225, 3304B
120G, 130G, 215B, 225, 3304B
3G2331
SHAFT
215, 215B
215, 215B
5C8582
SHAFT
215, 215B, 215C
215, 215B, 215C
9T3384
SHAFT
215B, 225
215B, 225
8U6998
SHAFT
205B, 206B, 211B, 212B
205B, 206B, 211B, 212B
8U7066
SHAFT AS
205B, 206B, 211B, 212B
205B, 206B, 211B, 212B
7T5653
SHAFT
235D, 245
235D, 245
4W6955
SHAFT-AUXILIARY DRIVE
235, 515, 525, 545, D7G, R1300, R1300G
235, 515, 525, 545, D7G, R1300, R1300G
5C9600
SHAFT
245
245
7W4751
SHAFT
224
224
7W4636
SHAFT-PUMP DRIVE
214, 224
214, 224
6T2191
SHAFT
245
245
8V2384
SHAFT
245
245
9T2562
SHAFT
215B
215B
9T2909
SHAFT
215B
215B
8V7079
SHAFT
235, 235B, 235C
235, 235B, 235C
4T9155
SHAFT
235, 235B
235, 235B