3798579 SHIELD AS Caterpillar parts
C11, C13
Rating:
Alternative (cross code) number:
CA3798579
379-8579
3798579
CA3798579
379-8579
3798579
Weight: 0.42 pounds 0 kg.
TRUCK ENGINE,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$129.89
20 Aug 2023
US: GAMA PARTS STOR
379-8579, CAT Shield Assembly - Exhaust Manifold
Generic Quick overview CAT Engine Exhaust Manifold Shield Assembly 3798579 - 10-13 Liter C11 & C13 || Please Note That Some Listings Use Stock Images As A Reference For Customers note that all OEM part numbers and logos are to be used for identification purposes only
Generic Quick overview CAT Engine Exhaust Manifold Shield Assembly 3798579 - 10-13 Liter C11 & C13 || Please Note That Some Listings Use Stock Images As A Reference For Customers note that all OEM part numbers and logos are to be used for identification purposes only
Information:
Introduction
The installation of a 7X1180 Internal Expansion Board (IEB) enhances the use of the 8T8697 Electronic Control Analyzer Programmer (ECAP). It provides an additional four sockets to install service program modules (SPM).After the IEB installation, the ECAP will have a total of seven sockets for service program module installation and use. The only tool necessary for removal and installation of the key board panel is a phillips screwdriver.Reference: SEHS8742, Using the 8T8697 Electronic Control Analyzer Programmer (ECAP).Installing the 7X1180 Internal Expansion Board
1. Remove eight screws (1) holding key board panel (2) of the ECAP. The two screws on the front edge of key board panel (2) are shorter than the other six screws. Make sure the two shorter screws are returned to the same holes during reinstallation. 2. Carefully lift key board panel (2) out of the case by lifting on Port #1 connector (3). 3. Carefully turn key board panel (2) over for access to main circuit board (4). 4. Locate SPM sockets (5) in the lower right corner of main circuit board (4). 5. Position IEB (6) to align SPM sockets U2, U3, U4 and U5 above SPM sockets U45, U46, U47 and U48. 6. Inspect for proper alignment of all pins and connectors between the IEB (6) and main circuit board (4). Make sure all connector pins and mounting connectors are aligned correctly, with each other, before proceeding to Step 7. 7. Press down, gently and evenly, at all four corners of IEB (6) until the connector pins start to engage with mounting connectors. 8. If the connector pins and mounting connectors have engaged properly, press IEB (6) down firmly, at all four corners, until support posts (7) "snap" into place.9. Make sure that all connector pins and mounting connectors have mated (engaged) correctly.10. If any of the connector pins and mounting connectors have NOT mated (engaged) correctly:* Remove the IEB.Refer to Removing the 7X1180 Internal Expansion Board, in this instruction.* Inspect each connector pin and carefully straighten if necessary.* Reinstall the IEB following the above Steps 4 thru 10. This completes the installation of the IEB.* If you are going to install additional SPM(s) (8), at this time, refer to SEHS8742.* If not, proceed to Step 11.11. Reinstall key board panel (2) into the case, using eight screws (1). Make sure the two shorter screws are returned to the same holes during reinstallation, as noted in Step 1.12. Power up (turn ON) the ECAP.Any SPM installed in the IEB should now appear on the LCD of the ECAP.If any or all of the SPM(s) do not display on the ECAP:* Inspect for power to the ECAP* Inspect for proper installation of the IEB.Refer to Installing the 7X1180 Internal Expansion Board, in this instruction.* Inspect for proper installation of the SPM(s).* Inspect each SPM to make sure you have not installed a duplicate.Removing the 7X1180 Internal Expansion Board
If any of the SPM(s) installed in sockets U45, U46, U47, or ECAP Executive Program Module U48, need
The installation of a 7X1180 Internal Expansion Board (IEB) enhances the use of the 8T8697 Electronic Control Analyzer Programmer (ECAP). It provides an additional four sockets to install service program modules (SPM).After the IEB installation, the ECAP will have a total of seven sockets for service program module installation and use. The only tool necessary for removal and installation of the key board panel is a phillips screwdriver.Reference: SEHS8742, Using the 8T8697 Electronic Control Analyzer Programmer (ECAP).Installing the 7X1180 Internal Expansion Board
1. Remove eight screws (1) holding key board panel (2) of the ECAP. The two screws on the front edge of key board panel (2) are shorter than the other six screws. Make sure the two shorter screws are returned to the same holes during reinstallation. 2. Carefully lift key board panel (2) out of the case by lifting on Port #1 connector (3). 3. Carefully turn key board panel (2) over for access to main circuit board (4). 4. Locate SPM sockets (5) in the lower right corner of main circuit board (4). 5. Position IEB (6) to align SPM sockets U2, U3, U4 and U5 above SPM sockets U45, U46, U47 and U48. 6. Inspect for proper alignment of all pins and connectors between the IEB (6) and main circuit board (4). Make sure all connector pins and mounting connectors are aligned correctly, with each other, before proceeding to Step 7. 7. Press down, gently and evenly, at all four corners of IEB (6) until the connector pins start to engage with mounting connectors. 8. If the connector pins and mounting connectors have engaged properly, press IEB (6) down firmly, at all four corners, until support posts (7) "snap" into place.9. Make sure that all connector pins and mounting connectors have mated (engaged) correctly.10. If any of the connector pins and mounting connectors have NOT mated (engaged) correctly:* Remove the IEB.Refer to Removing the 7X1180 Internal Expansion Board, in this instruction.* Inspect each connector pin and carefully straighten if necessary.* Reinstall the IEB following the above Steps 4 thru 10. This completes the installation of the IEB.* If you are going to install additional SPM(s) (8), at this time, refer to SEHS8742.* If not, proceed to Step 11.11. Reinstall key board panel (2) into the case, using eight screws (1). Make sure the two shorter screws are returned to the same holes during reinstallation, as noted in Step 1.12. Power up (turn ON) the ECAP.Any SPM installed in the IEB should now appear on the LCD of the ECAP.If any or all of the SPM(s) do not display on the ECAP:* Inspect for power to the ECAP* Inspect for proper installation of the IEB.Refer to Installing the 7X1180 Internal Expansion Board, in this instruction.* Inspect for proper installation of the SPM(s).* Inspect each SPM to make sure you have not installed a duplicate.Removing the 7X1180 Internal Expansion Board
If any of the SPM(s) installed in sockets U45, U46, U47, or ECAP Executive Program Module U48, need
Caterpillar parts catalog:
Parts shield Caterpillar catalog:
7E7978
SHIELD
14M, 16M, 3176, 3176C, 345C, 345C L, 345C MH, 345D, 345D L, 345D L VG, 349D, 349D L, 349E, 349E L, 349E L HVG, 349E L VG, 349F L, 621H, 621K, 623H, 623K, 623K LRC, 627H, 627K, 627K LRC, 725, 730, 730C...
14M, 16M, 3176, 3176C, 345C, 345C L, 345C MH, 345D, 345D L, 345D L VG, 349D, 349D L, 349E, 349E L, 349E L HVG, 349E L VG, 349F L, 621H, 621K, 623H, 623K, 623K LRC, 627H, 627K, 627K LRC, 725, 730, 730C...
3401135
SHIELD-HEAT
C13, TH35-C13T
C13, TH35-C13T
3401136
SHIELD-HEAT
C13, TH35-C13T
C13, TH35-C13T
3401137
SHIELD-HEAT
C13, TH35-C13T
C13, TH35-C13T
3401138
SHIELD-HEAT
C13, TH35-C13T
C13, TH35-C13T
3135972
SHIELD-HEAT
C13, TH35-C13T
C13, TH35-C13T
3082684
SHIELD-HEAT
C13, TH35-C13T
C13, TH35-C13T
2386735
SHIELD-HEAT
C13, TH35-C13T
C13, TH35-C13T
2846693
SHIELD-HEAT
C13, TH35-C13T
C13, TH35-C13T
2761954
SHIELD-HEAT
C13, TH35-C13T
C13, TH35-C13T
2884317
SHIELD-HEAT
C13, TH35-C13T
C13, TH35-C13T
2497039
SHIELD-HEAT
C11, C13
C11, C13
2874501
SHIELD-HEAT
C15, TH35-C15T
C15, TH35-C15T
2585671
SHIELD
C15
C15
1590051
SHIELD
3176C, 3196, C-10, C-12
3176C, 3196, C-10, C-12
2303284
SHIELD-HEAT
C11, C13
C11, C13
2386736
SHIELD-HEAT
C11, C13
C11, C13
2296717
SHIELD-HEAT
C11, C13
C11, C13
2428826
SHIELD-HEAT
C11, C13, RM-300
C11, C13, RM-300
2197424
SHIELD-HEAT
C11, C13
C11, C13
2509273
SHIELD
C11, C13, TH35-C13T
C11, C13, TH35-C13T