4469502 SHIM Caterpillar parts
Rating:
Alternative (cross code) number:
CA4469502
446-9502
4469502
CA4469502
446-9502
4469502
Weight: 0.42 pounds 0 kg.
Information:
Personal injury or death can result from high voltage.When power generation equipment must be in operation to make tests and/or adjustments, high voltage and current are present.Improper test equipment can fail and present a high voltage shock hazard to its user.Make sure the testing equipment is designed for and correctly operated for high voltage and current tests being made.When servicing or repairing electric power generation equipment:
Make sure the unit is off-line (disconnected from utility and/or other generators power service), and either locked out or tagged DO NOT OPERATE.
Remove all fuses.
Make sure the generator engine is stopped.
Make sure all batteries are disconnected.
Make sure all capacitors are discharged.Failure to do so could result in personal injury or death. Make sure residual voltage in the rotor, stator and the generator is discharged.
Accidental engine starting can cause injury or death to personnel working on the equipment.To avoid accidental engine starting, disconnect the battery cable from the negative (−) battery terminal. Completely tape all metal surfaces of the disconnected battery cable end in order to prevent contact with other metal surfaces which could activate the engine electrical system.Place a Do Not Operate tag at the Start/Stop switch location to inform personnel that the equipment is being worked on.
In order to modify the connections, change the position of the shunts on the terminals. The code for the generator windings is specified on the nameplate for the generator.
Illustration 1 g00992028
Note: The generator should be connected with the terminal lugs on top of each other. Refer to Illustration 1.Grounding the Frame
In any generator set installation, the frame of the generator must be positively connected to an earth ground or to the hull of a vessel. This connection is the first connection that is made at the installation. This connection is the last connection that should be removed. If the generator set is on flexible mounting pads, the ground connection must be flexible in order to avoid possible breakage in later operation.Ground connection cable or straps should have at least the current carrying capacity of the largest line lead to the connected load. Joints in cables or straps must be clean, free of electrical resistance, and protected from possible oxidation. Bolted ground connection joints eventually oxidize. The joints are frequent sources of Radio Frequency Interference (RFI). Joints that are silver soldered and bolted are preferred.Neutral Connections
The generators with a Wye Configuration usually have the neutral ground when the generator is installed. Grounding the neutral is for preventing damage to equipment.If the neutral wire is grounded and one of the phase leads becomes grounded, the excessive current will open a load circuit breaker. Also, the excessive current will cause the generator voltage to collapse. The result depends on the following items: electrical characteristics of the generator, type of fault and trip rating of the circuit breaker. An undervoltage device may be required in order to provide an adequate short circuit protection.There are some cases when the neutral wire is not grounded. An ungrounded generator neutral lead is acceptable
Parts shim Caterpillar catalog:
4467191
SHIM
Caterpillar
Caterpillar
4467158
SHIM
Caterpillar
Caterpillar
4463119
SHIM AS-PACK
Caterpillar
Caterpillar
4463083
SHIM
Caterpillar
Caterpillar
4463081
SHIM PACK
Caterpillar
Caterpillar
4463080
SHIM
Caterpillar
Caterpillar
4491767
SHIM
Caterpillar
Caterpillar
4491766
SHIM
Caterpillar
Caterpillar
4491765
SHIM
Caterpillar
Caterpillar
4477231
SHIM
Caterpillar
Caterpillar
4477230
SHIM
Caterpillar
Caterpillar
4477229
SHIM
Caterpillar
Caterpillar