7Y2496 SHIM Caterpillar parts
1090, 1190, 1190T, 1290T, 2290, 2390, 2391, 2491, 315, 317, 318C, 319C, 319D, 319D L, 319D LN, 320 L, 320B, 320B FM LL, 320B L, 320C, 320C FM, 320D, 320E LN, 320N, 322, 322 FM L, 322 LN, 322B, 322B L,...
Rating:
Alternative (cross code) number:
CA7Y2496
7Y-2496
7Y2496
CA7Y2496
7Y-2496
7Y2496
Weight: 0.25 pounds 0 kg.
Information:
ID
72
mm
MATERIAL THICKNESS
1.6
mm
OD
130
mm
EXCAVATOR, WHEELED EXCAVATOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$11.17
21 Mar 2022
US: Florida-Parts-Z
7Y2496 - Shim (1.6mm Thick) for Caterpillar (CAT)
FIRST PRICE PARTS
FIRST PRICE PARTS
Compatible equipment models: 7Y2496:
EXCAVATOR
315
317
318C
319C
319D
319D L
319D LN
320 L
320B
320B FM LL
320B L
320C
320C FM
320D
320E LN
320N
322
322 FM L
322 LN
322B
322B L
322B LN
322C FM
323D L
323D LN
323D SA
323D2 L
323E L
324D FM
324D FM LL
325
325 L
325 LN
325B
325B L
325C
325D
325D L
330
330 FM L
330 L
330B L
330C
330D L
345B II
345B L
345C
345C L
345D
345D L
349D
349D L
349E L
349E L VG
349F L
350 L
365B
365B II
365C
365C L
375
385B
385C L
E120B
E200B
E240C
E70B
EL240B
M325D L MH
M325D MH
FRONT SHOVEL
5080
LOGGER
322C
Information:
Chapter 3. Operation and Adjustment
Initial Pre-Start Settings
-OVERSPEEDOverspeed with resultant equipment damage, personal injury, or death is possible when setting up a control system. Read this entire procedure before starting the prime mover for the first time.
CAUTION-DO NOT TURN POTS BEYOND THEIR STOPSThe Rated Speed Potentiometer is the only multi-turn pot in this control. All other pots are single-turn. Take care not to turn these pots beyond their stops.
1. RATED SPEEDa. Set the RATED SPEED potentiometer to minimum (fully counterclockwise in ten-turn potentiometer).b. Set the external SPEED TRIM, if used, to mid-position.2. RESET- Set at mid-position. (One-turn potentiometer).3. GAIN- Set at mid-position. (One-turn potentiometer).4. RAMP TIME- Set at minimum (fully ccw, one-turn potentiometer- be careful not to overtorque the pot ).5. LOW IDLE SPEED- Set at minimum (fully ccw, one-turn potentiometer- be careful not to overtorque the pot ).6. DROOP- Set optional external droop (if used) at minimum (fully counterclockwise, one-turn potentiometer- be careful not to overtorque the pot ).7. ACTUATOR COMPENSATION (One-turn potentiometer)a. DIESEL, GAS TURBINE, FUEL-INJECTED GASOLINE PRIME MOVERS: Set the ACTUATOR COMPENSATION potentiometer at 2 on the 0 to 10 scale.b. CARBURETED GAS OR GASOLINE or STEAM TURBINE PRIME MOVERS: Set the ACTUATOR COMPENSATION potentiometer at 6 on the 0 to 10 scale.8. START FUEL LIMIT- Set at maximum (fully cw one-turn potentiometer- be careful not to overtorque the pot ).9. Be sure the actuator is connected to terminals 9 (+) and 10 (-).Start-up Adjustments
1. Complete the installation checkout procedure in Chapter 2, and the initial prestart settings above.2. Close the Close for Rated contact. If the external droop feature is being used it should already be set at isochronous, fully ccw be careful not to overtorque the pot). This is for initial prime mover start-up only. For normal start-up, the Close for Rated contact should be open if the prime mover is to start at idle.3. Apply input power to the control.4. Preset rated speed.If a signal generator is not used, set the RATED SPEED potentiometer at minimum (fully counterclockwise).If a signal is not used set the signal for the frequency of the speed sensor at rated speed, and connect it to terminals 7 and 8. (The rated speed frequency in Hz equals the rated engine speed in RPM times the number of teeth on the speed sensing gear, times the ratio of engine speed to speed-sensing-gear speed, divided by 60.) Put the Close For Rated contact in rated (closed) position set the speed trim potentiometer (if used) to mid position. Connect a dc analog voltmeter to terminals 9 (+) and 10 (-) to read actuator voltage.If the actuator voltage is at minimum (about 0 volts) slowly turn the RATED SPEED potentiometer clockwise (counterclockwise for reverse acting controls) until the voltage just begins to move toward maximum.If the actuator voltage is at maximum, slowly turn the RATED SPEED potentiometer counterclockwise (clockwise for reverse acting controls) until the voltage just begins to move toward minimum.Continue to very slowly adjust the RATED SPEED potentiometer in the appropriate
Initial Pre-Start Settings
-OVERSPEEDOverspeed with resultant equipment damage, personal injury, or death is possible when setting up a control system. Read this entire procedure before starting the prime mover for the first time.
CAUTION-DO NOT TURN POTS BEYOND THEIR STOPSThe Rated Speed Potentiometer is the only multi-turn pot in this control. All other pots are single-turn. Take care not to turn these pots beyond their stops.
1. RATED SPEEDa. Set the RATED SPEED potentiometer to minimum (fully counterclockwise in ten-turn potentiometer).b. Set the external SPEED TRIM, if used, to mid-position.2. RESET- Set at mid-position. (One-turn potentiometer).3. GAIN- Set at mid-position. (One-turn potentiometer).4. RAMP TIME- Set at minimum (fully ccw, one-turn potentiometer- be careful not to overtorque the pot ).5. LOW IDLE SPEED- Set at minimum (fully ccw, one-turn potentiometer- be careful not to overtorque the pot ).6. DROOP- Set optional external droop (if used) at minimum (fully counterclockwise, one-turn potentiometer- be careful not to overtorque the pot ).7. ACTUATOR COMPENSATION (One-turn potentiometer)a. DIESEL, GAS TURBINE, FUEL-INJECTED GASOLINE PRIME MOVERS: Set the ACTUATOR COMPENSATION potentiometer at 2 on the 0 to 10 scale.b. CARBURETED GAS OR GASOLINE or STEAM TURBINE PRIME MOVERS: Set the ACTUATOR COMPENSATION potentiometer at 6 on the 0 to 10 scale.8. START FUEL LIMIT- Set at maximum (fully cw one-turn potentiometer- be careful not to overtorque the pot ).9. Be sure the actuator is connected to terminals 9 (+) and 10 (-).Start-up Adjustments
1. Complete the installation checkout procedure in Chapter 2, and the initial prestart settings above.2. Close the Close for Rated contact. If the external droop feature is being used it should already be set at isochronous, fully ccw be careful not to overtorque the pot). This is for initial prime mover start-up only. For normal start-up, the Close for Rated contact should be open if the prime mover is to start at idle.3. Apply input power to the control.4. Preset rated speed.If a signal generator is not used, set the RATED SPEED potentiometer at minimum (fully counterclockwise).If a signal is not used set the signal for the frequency of the speed sensor at rated speed, and connect it to terminals 7 and 8. (The rated speed frequency in Hz equals the rated engine speed in RPM times the number of teeth on the speed sensing gear, times the ratio of engine speed to speed-sensing-gear speed, divided by 60.) Put the Close For Rated contact in rated (closed) position set the speed trim potentiometer (if used) to mid position. Connect a dc analog voltmeter to terminals 9 (+) and 10 (-) to read actuator voltage.If the actuator voltage is at minimum (about 0 volts) slowly turn the RATED SPEED potentiometer clockwise (counterclockwise for reverse acting controls) until the voltage just begins to move toward maximum.If the actuator voltage is at maximum, slowly turn the RATED SPEED potentiometer counterclockwise (clockwise for reverse acting controls) until the voltage just begins to move toward minimum.Continue to very slowly adjust the RATED SPEED potentiometer in the appropriate
Cat SIS web machinery list:
Parts shim Caterpillar catalog:
2676863
SHIM
320D, 320D FM, 320D FM RR, 322C, 323D LN, 323D SA, 323E L, 324D, 324D L, 324D LN, 324E, 324E L, 324E LN, 325C, 325D, 325D L, 325D MH, 326D L, 329D, 329D L, 329D LN, 329E, 329E L, 329E LN, OEMS
320D, 320D FM, 320D FM RR, 322C, 323D LN, 323D SA, 323E L, 324D, 324D L, 324D LN, 324E, 324E L, 324E LN, 325C, 325D, 325D L, 325D MH, 326D L, 329D, 329D L, 329D LN, 329E, 329E L, 329E LN, OEMS
4I6604
SHIM
115, 324D, 324D L, 324D LN, 324E, 324E L, 324E LN, 325B L, 325C, 325D, 325D L, 326D L, 328D LCR, 329D, 329D L, 329D LN, 329E, 329E L, 329E LN, 330, 330 FM L, 330 L, 330B, 330B L, 330C, 330C L, 330D, 3...
115, 324D, 324D L, 324D LN, 324E, 324E L, 324E LN, 325B L, 325C, 325D, 325D L, 326D L, 328D LCR, 329D, 329D L, 329D LN, 329E, 329E L, 329E LN, 330, 330 FM L, 330 L, 330B, 330B L, 330C, 330C L, 330D, 3...
4I6605
SHIM
115, 324D, 324D L, 324D LN, 324E, 324E L, 324E LN, 325B L, 325C, 325D, 325D L, 326D L, 328D LCR, 329D, 329D L, 329D LN, 329E, 329E L, 329E LN, 330, 330 FM L, 330 L, 330B, 330B L, 330C, 330C L, 330D, 3...
115, 324D, 324D L, 324D LN, 324E, 324E L, 324E LN, 325B L, 325C, 325D, 325D L, 326D L, 328D LCR, 329D, 329D L, 329D LN, 329E, 329E L, 329E LN, 330, 330 FM L, 330 L, 330B, 330B L, 330C, 330C L, 330D, 3...
4I4039
SHIM
324D L, 325D L, 328D LCR, 329D L, 330D, 330D L, 330D LN, 336D, 336D L, 336D LN, 336D2, 336D2 L, 336E, 336E H, 336E L, 336E LN, 340D L, 340D2 L, 345B II, 345B L, 345C, 345C L, 345D, 345D L, 345D L VG, ...
324D L, 325D L, 328D LCR, 329D L, 330D, 330D L, 330D LN, 336D, 336D L, 336D LN, 336D2, 336D2 L, 336E, 336E H, 336E L, 336E LN, 340D L, 340D2 L, 345B II, 345B L, 345C, 345C L, 345D, 345D L, 345D L VG, ...
4I4043
SHIM
324D L, 325D L, 328D LCR, 329D L, 330D, 330D L, 330D LN, 336D, 336D L, 336D LN, 336D2, 336D2 L, 336E, 336E H, 336E L, 336E LN, 340D L, 340D2 L, 345B II, 345B L, 345C, 345C L, 345D, 345D L, 345D L VG, ...
324D L, 325D L, 328D LCR, 329D L, 330D, 330D L, 330D LN, 336D, 336D L, 336D LN, 336D2, 336D2 L, 336E, 336E H, 336E L, 336E LN, 340D L, 340D2 L, 345B II, 345B L, 345C, 345C L, 345D, 345D L, 345D L VG, ...
1107234
SHIM
330B, 330B L, OEMS
330B, 330B L, OEMS
1107235
SHIM
330B, 330B L, OEMS
330B, 330B L, OEMS
2122841
SHIM
330C, 330C FM, 330C L, 330C MH, 330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 336E, 336E H, 336E HVG, 336E L, 336E LH, 336E LN, 336F L, 340D L, 340D2 L, M330D
330C, 330C FM, 330C L, 330C MH, 330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 336E, 336E H, 336E HVG, 336E L, 336E LH, 336E LN, 336F L, 340D L, 340D2 L, M330D
5I4480
SHIM
330, 330 FM L, 330 L, 330B, 330B L, 345B, 345B L, W330B
330, 330 FM L, 330 L, 330B, 330B L, 345B, 345B L, W330B
5I4481
SHIM
330, 330 FM L, 330 L, 330B, 330B L, 345B, 345B L, W330B
330, 330 FM L, 330 L, 330B, 330B L, 345B, 345B L, W330B
5I4482
SHIM
330, 330 FM L, 330 L, 330B, 330B L, 345B, 345B L, W330B
330, 330 FM L, 330 L, 330B, 330B L, 345B, 345B L, W330B
5I4483
SHIM
330, 330 FM L, 330 L, 330B, 330B L, 345B, 345B L, W330B
330, 330 FM L, 330 L, 330B, 330B L, 345B, 345B L, W330B
2506989
SHIM
TH220B, TH580B
TH220B, TH580B
2506988
SHIM
TH220B, TH580B
TH220B, TH580B
3008828
SHIM
TH220B, TH580B
TH220B, TH580B
2226312
SHIM
TH220B, TH580B
TH220B, TH580B
2226311
SHIM
TH220B, TH580B
TH220B, TH580B
2478479
SHIM
TH220B, TH580B
TH220B, TH580B
2939884
SHIM
416E, 416F, 420E, 420F, 430E, 430F, 450E, 450F
416E, 416F, 420E, 420F, 430E, 430F, 450E, 450F
2939882
SHIM
416E, 416F, 420E, 420F, 430E, 430F, 450E, 450F
416E, 416F, 420E, 420F, 430E, 430F, 450E, 450F
2875667
SHIM
416E, 416F, 420E, 420F, 422E, 428E, 430E, 430F, 432E, 434E, 442E, 444E, 450E, 450F
416E, 416F, 420E, 420F, 422E, 428E, 430E, 430F, 432E, 434E, 442E, 444E, 450E, 450F
2335167
SHIM
416E, 416F, 420E, 420F, 422E, 428E, 430E, 430F, 432E, 434E, 442E, 444E, 450E, 450F
416E, 416F, 420E, 420F, 422E, 428E, 430E, 430F, 432E, 434E, 442E, 444E, 450E, 450F
2335166
SHIM
416E, 416F, 420E, 420F, 422E, 428E, 430E, 430F, 432E, 434E, 442E, 444E, 450E, 450F
416E, 416F, 420E, 420F, 422E, 428E, 430E, 430F, 432E, 434E, 442E, 444E, 450E, 450F
1332424
SHIM
311D LRR, 312D, 312E, 314D LCR, 314E LCR, 315, 315B, 315B FM L, 315B L, 315C, 315D L, 316E L, 317B LN, 318B, 318D L, 318D2 L, 318E L, 320 L, 320B, 320B FM LL, 320B L, 320C, 320C FM, 320D, 322B, 322B L...
311D LRR, 312D, 312E, 314D LCR, 314E LCR, 315, 315B, 315B FM L, 315B L, 315C, 315D L, 316E L, 317B LN, 318B, 318D L, 318D2 L, 318E L, 320 L, 320B, 320B FM LL, 320B L, 320C, 320C FM, 320D, 322B, 322B L...