AVSPARE.COM
parts catalog

SHUT-OFF GP-MECHANICAL 5N3661 - Caterpillar


5N3661 SHUT-OFF GP-MECHANICAL Caterpillar parts D346, D348, D349
Rating:
21
Alternative (cross code) number:
CA5N3661
5N-3661
5N3661
Caterpillar 5N3661 SHUT-OFF GP-MECHANICAL

Buy SHUT-OFF GP-MECHANICAL 5N3661 Caterpillar genuine, new aftermarket tractor parts with delivery
INDUSTRIAL ENGINE, MARINE ENGINE,

Compatible equipment models: 5N3661:

INDUSTRIAL ENGINE  D346   D348   D349  
MARINE ENGINE  D346   D348   D349   Caterpillar
Number on catalog scheme:
  For full view, you need register

Information:

Fuse Failure Modes
Open
An open fuse is the result of system overload. Fuses with the element visible can give a clue as to the cause. Testing on a questionable fuse only requires a 6V7070 Multimeter (or equivalent) on the 200 ohm scale. A good fuse will read less than approximately 0.2 ohms. An open fuse will read "OL" for open circuit.
1. The glass or plastic housing is smoked or blackened. This is caused by gross circuit overload far beyond the fuse rating. This is usually caused by a short circuit-to-ground from: ...Incorrect troubleshooting as with a screwdriver.
...A component short as in a forward warning horn.
...A harness short where a wire (conductor) is pinched to make a connection to ground.
2. The glass or plastic housing is clear showing the fuse element simply melted open. This is caused by a gentle overload somewhat greater than the fuse rating.Will not fit fuse holder
1. Incorrect type or size of fuse for holder.2. Supplier tolerances are incorrect.Breaker Failure Modes
Open
An open circuit breaker is an automatic or manual breaker that will not reset (reads "OL" on 6V7070 Multimeter). This usually occurs from gross circuit overload far beyond the breaker current rating. This is usually caused by a short circuit-to-ground from: ...Incorrect troubleshooting as with a screwdriver....A component short as in a forward warning horn....A harness short where a wire (conductor) is pinched to make a connection to ground.
Failure of a circuit breaker to reset is often caused by a melted disk or a disk that was so hot during overload that it is warped and cannot be reset to a closed position.
Shorted
A shorted circuit breaker, one that will not open under an overload, is rare and might be found in a circuit with wiring and/or harness damage. This may possibly be caused by an overload condition that welded the disk in place.


Parts shut Caterpillar catalog:

2N6262 SHUT-OFF GP
D346, D348, D349
3N0584 SHUT-OFF GP-SOLENOID
3304, 3306, 3406, 3408, 3412, D343, D346, D348, D349, D379, D379A, D398, D398A, D399
3N2849 SHUT-OFF GP
D346, D348, D349
5N3736 SHUT-OFF GP
D346, D348, D349
3N7742 SHUT-OFF GP
3306, 3406, 3406C
7S9480 SHUT-OFF GP
627, 637, 657B, 666, D6C
Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.