2727094 SHUTOFF GP-AIR Caterpillar parts
3508, 3508B, 3508C, 3512B, 3512C, 3516B
Rating:
Alternative (cross code) number:
CA2727094
272-7094
2727094
CA2727094
272-7094
2727094
Weight: 25 pounds 11 kg.
GEN SET ENGINE, PETROLEUM ENGINE,
This part in 2 request:
Show.
This information for suppliers only!
2021-04-20
2017-05-16
Compatible equipment models: 2727094:
Information:
Fuel Recommendations
Cat gas engines will operate successfully on a broad range of gaseous fuels. Pipeline natural gas has been used for many years. Commercial fuel gases are mixtures of gases. These fuels consist primarily of hydrocarbons (combinations of hydrogen and carbon) and some inert gases. The compositions of these gas mixtures have extreme variations. Contact your Cat dealer before using fuels such as wellhead gas, bio-gas, and manufactured gas. Analyze the fuel in order to determine the following characteristics:
Composition
Contaminants
Heat value
Methane number
Specific gravityField gas can have varying characteristics of combustion. Field gas can contain numerous harmful impurities. The impurities can alter the BTU content. The impurities can also alter the methane number. The impurities include everything from water up to complex hydrocarbons that can lead to detonation and severe engine damage. To minimize these effects, Caterpillar recommends the following guidelines:
Ensure the use of an engine that is configured for a fuel that has a high energy. Consult your local Cat Dealer in order to determine the recommended engine timing. For specific timing recommendations and fuel setup refer to Special Instructions, REHS6590 or contact the local Cat® dealership. For further information on fuels, see Special Publication, SEBU6400, "Caterpillar Gas Engine Lubricant, Fuel, and Coolant Recommendations".Coolant Recommendations
During shipping and storage, the engine must be protected from damage that can be caused by freezing of the cooling system. The cooling system must contain antifreeze that will withstand the lowest ambient temperature If the engine is shipped to a site with freezing temperatures and if the engine is stored in a location with freezing temperatures. Frequently check the concentration of glycol in the coolant/antifreeze. Make sure that the concentration is adequate in order to prevent freezing. If the coolant may be subject to freezing conditions, completely drain the cooling system.Coolant/antifreeze is normally composed of three elements: water, glycol and additives. Each element must meet specific guidelines.Water
Deionized water or distilled water is recommended for use in engine cooling systems. If distilled water or deionized water is not available, use water with the properties that are listed in Table 2.
Table 2
Caterpillar Minimum Acceptable Water Requirements
Property Maximum Limit ASTM Test
Chloride (Cl) 40 mg/L (2.4 gr per US gal) "D512", "D4327"
Sulfate (SO4) 100 mg/L (5.9 gr per US gal) "D516"
Total Hardness 170 mg/L (10 gr per US gal) "D1126"
Total Solids 340 mg/L (20 gr per US gal) "D1888"
Acidity pH of 5.5 to 9.0 "D1293"
Use of water that does not meet the recommendations for the cooling system will damage the cooling system.Do not use these types of water in the cooling system: sea water, softened water that has been conditioned with salt, hard water and tap water.Only use water that meets the recommendations for the cooling system.
If you are not sure about the properties of your water, consult one of the following sources for a water analysis:
Cat dealer
Local water utility company
Agricultural agent
Independent laboratoryGlycol
Do not use Extended Life Coolant (ELC) with Cat Gas Engines.ELC was not formulated for use in Cat Gas Engines.Do not use
Cat gas engines will operate successfully on a broad range of gaseous fuels. Pipeline natural gas has been used for many years. Commercial fuel gases are mixtures of gases. These fuels consist primarily of hydrocarbons (combinations of hydrogen and carbon) and some inert gases. The compositions of these gas mixtures have extreme variations. Contact your Cat dealer before using fuels such as wellhead gas, bio-gas, and manufactured gas. Analyze the fuel in order to determine the following characteristics:
Composition
Contaminants
Heat value
Methane number
Specific gravityField gas can have varying characteristics of combustion. Field gas can contain numerous harmful impurities. The impurities can alter the BTU content. The impurities can also alter the methane number. The impurities include everything from water up to complex hydrocarbons that can lead to detonation and severe engine damage. To minimize these effects, Caterpillar recommends the following guidelines:
Ensure the use of an engine that is configured for a fuel that has a high energy. Consult your local Cat Dealer in order to determine the recommended engine timing. For specific timing recommendations and fuel setup refer to Special Instructions, REHS6590 or contact the local Cat® dealership. For further information on fuels, see Special Publication, SEBU6400, "Caterpillar Gas Engine Lubricant, Fuel, and Coolant Recommendations".Coolant Recommendations
During shipping and storage, the engine must be protected from damage that can be caused by freezing of the cooling system. The cooling system must contain antifreeze that will withstand the lowest ambient temperature If the engine is shipped to a site with freezing temperatures and if the engine is stored in a location with freezing temperatures. Frequently check the concentration of glycol in the coolant/antifreeze. Make sure that the concentration is adequate in order to prevent freezing. If the coolant may be subject to freezing conditions, completely drain the cooling system.Coolant/antifreeze is normally composed of three elements: water, glycol and additives. Each element must meet specific guidelines.Water
Deionized water or distilled water is recommended for use in engine cooling systems. If distilled water or deionized water is not available, use water with the properties that are listed in Table 2.
Table 2
Caterpillar Minimum Acceptable Water Requirements
Property Maximum Limit ASTM Test
Chloride (Cl) 40 mg/L (2.4 gr per US gal) "D512", "D4327"
Sulfate (SO4) 100 mg/L (5.9 gr per US gal) "D516"
Total Hardness 170 mg/L (10 gr per US gal) "D1126"
Total Solids 340 mg/L (20 gr per US gal) "D1888"
Acidity pH of 5.5 to 9.0 "D1293"
Use of water that does not meet the recommendations for the cooling system will damage the cooling system.Do not use these types of water in the cooling system: sea water, softened water that has been conditioned with salt, hard water and tap water.Only use water that meets the recommendations for the cooling system.
If you are not sure about the properties of your water, consult one of the following sources for a water analysis:
Cat dealer
Local water utility company
Agricultural agent
Independent laboratoryGlycol
Do not use Extended Life Coolant (ELC) with Cat Gas Engines.ELC was not formulated for use in Cat Gas Engines.Do not use
Caterpillar SIS machinery equipment:
Caterpillar SIS
3516B Marine Engine 8KN00001-UP »
272-7094
SHUTOFF GP-AIR
3516B Marine Engine 8CN00001-UP »
272-7094
SHUTOFF GP-AIR
3516B Marine Auxiliary Engine 9AN00001-UP »
272-7094
SHUTOFF GP-AIR
3512B Generator Set Engine 8RM00001-UP »
272-7094
SHUTOFF GP-AIR
3512B Marine Engine 4TN00001-UP »
272-7094
SHUTOFF GP-AIR
3512B Marine Engine 7HM00001-UP »
272-7094
SHUTOFF GP-AIR
3512B Marine Auxiliary Engine 8EM00001-UP »
272-7094
SHUTOFF GP-AIR
3508B Generator Set Engine 6PN00001-UP »
272-7094
SHUTOFF GP-AIR
3508B Marine Engine 7SM00001-UP »
272-7094
SHUTOFF GP-AIR
3508B Marine Engine 2BM00001-UP »
272-7094
SHUTOFF GP-AIR
3508B Marine Auxiliary Engine 3DM00001-UP »
272-7094
SHUTOFF GP-AIR
3508B Marine Auxiliary Engine 3DW00001-UP »
272-7094
SHUTOFF GP-AIR
3512B Marine Auxiliary Engine 1PW00001-UP »
272-7094
SHUTOFF GP-AIR
3516B Marine Auxiliary Engine 2FW00001-UP »
272-7094
SHUTOFF GP-AIR
3508B Marine Engine 1TW00001-UP »
272-7094
SHUTOFF GP-AIR
3516B Marine Engine 3CW00001-UP »
272-7094
SHUTOFF GP-AIR
3508B Generator Set Engine 2HW00001-UP »
272-7094
SHUTOFF GP-AIR
3512B Generator Set Engine 4AW00001-UP »
272-7094
SHUTOFF GP-AIR
3516B Generator Set Engine 1NW00001-UP »
272-7094
SHUTOFF GP-AIR
3512B High Displacement Generator Set Engine 5AW00001-UP »
272-7094
SHUTOFF GP-AIR
3512B Marine Long Stroke Engine 2EZ00001-UP »
272-7094
SHUTOFF GP-AIR
3516B Marine Long Stroke Engine 4BW00001-UP »
272-7094
SHUTOFF GP-AIR
3508B Marine Auxiliary Engine Military BAG00001-UP »
272-7094
SHUTOFF GP-AIR
3508B Industrial Engine BPX00001-UP »
272-7094
SHUTOFF GP-AIR
3512B Industrial Engine BRC00001-UP »
272-7094
SHUTOFF GP-AIR
3508B Industrial Engine CBB00001-UP »
272-7094
SHUTOFF GP-AIR
3516B High Displacement Marine Auxiliary Engine CBN00001-UP »
272-7094
SHUTOFF GP-AIR
3516B High Displacement Marine Engine CDE00001-UP »
272-7094
SHUTOFF GP-AIR
3508B Generator Set CNB00001-UP »
272-7094
SHUTOFF GP-AIR
3512B Generator Set CMC00001-UP »
272-7094
SHUTOFF GP-AIR
3508B Generator Set BGX00001-UP »
272-7094
SHUTOFF GP-AIR
3512B Generator Set BLF00001-UP »
272-7094
SHUTOFF GP-AIR
3516B Generator Set BMB00001-UP »
272-7094
SHUTOFF GP-AIR
3512B Generator Set BRK00001-UP »
272-7094
SHUTOFF GP-AIR
3516B Generator Set CPA00001-UP »
272-7094
SHUTOFF GP-AIR
3512B High Displacement Marine Engine BRN00001-UP »
272-7094
SHUTOFF GP-AIR
3512B Generator Set Oil Field Land Rig PTF00001-UP »
272-7094
SHUTOFF GP-AIR
3508B Generator Set Oil Field Land Rig PTN00001-UP »
272-7094
SHUTOFF GP-AIR
3508B Marine Auxiliary S2A00001-UP »
272-7094
SHUTOFF GP-AIR
3508B Marine Auxiliary Engine S2B00001-UP »
272-7094
SHUTOFF GP-AIR
3508B Marine Engine S2D00001-UP »
272-7094
SHUTOFF GP-AIR
3508B Marine Engine S2E00001-UP »
272-7094
SHUTOFF GP-AIR
3508B Marine Engine S2F00001-UP »
272-7094
SHUTOFF GP-AIR
3512B Marine Auxiliary Engine S2G00001-UP »
272-7094
SHUTOFF GP-AIR
3512B Marine Auxiliary Engine S2H00001-UP »
272-7094
SHUTOFF GP-AIR
3512B Marine Engine S2J00001-UP »
272-7094
SHUTOFF GP-AIR
3512B Marine Engine S2K00001-UP »
272-7094
SHUTOFF GP-AIR
3512B Marine Engine S2L00001-UP »
272-7094
SHUTOFF GP-AIR
3512B Marine Engine S2M00001-UP »
272-7094
SHUTOFF GP-AIR
3512B Marine Engine S2N00001-UP »
272-7094
SHUTOFF GP-AIR
3516B Marine Auxiliary Engine S2P00001-UP »
272-7094
SHUTOFF GP-AIR
3516B Marine Auxiliary Engine S2R00001-UP »
272-7094
SHUTOFF GP-AIR
3516B Marine Engine S2S00001-UP »
272-7094
SHUTOFF GP-AIR
3516B Marine Engine S2T00001-UP »
272-7094
SHUTOFF GP-AIR
3516B Marine Engine S2W00001-UP »
272-7094
SHUTOFF GP-AIR
3516B Marine Engine S2X00001-UP »
272-7094
SHUTOFF GP-AIR
3516B Marine Engine S2Y00001-UP »
272-7094
SHUTOFF GP-AIR
3516B Generator Set GZY00001-UP »
272-7094
SHUTOFF GP-AIR
3516B Generator Set GZT00001-UP »
272-7094
SHUTOFF GP-AIR
3512B Marine Engine Military NSC00001-UP »
272-7094
SHUTOFF GP-AIR
3508B Generator Set ZAD00001-UP »
272-7094
SHUTOFF GP-AIR
3512B Generator Set ZAH00001-UP »
272-7094
SHUTOFF GP-AIR
3512B Generator Set ZAJ00001-UP »
272-7094
SHUTOFF GP-AIR
3512C Engine LLA00001-UP »
272-7094
SHUTOFF GP-AIR
3512C Engine LLB00001-UP »
272-7094
SHUTOFF GP-AIR
3508C Engine LLC00001-UP »
272-7094
SHUTOFF GP-AIR
3512C Generator Set RMS00001-UP »
272-7094
SHUTOFF GP-AIR
3516B Marine Auxiliary Engine S2Z00001-UP »
272-7094
SHUTOFF GP-AIR
3508C Industrial Engine LLE00001-UP »
272-7094
SHUTOFF GP-AIR
3512C Industrial Engine LLF00001-UP »
272-7094
SHUTOFF GP-AIR
Cat SIS web machinery list:
Parts shutoff Caterpillar catalog:
2W5531
SHUTOFF GP-MANUAL
3508, 3508B, 3508C, 3512, 3512B, 3516, 3516B
3508, 3508B, 3508C, 3512, 3512B, 3516, 3516B
2727099
SHUTOFF GP-AIR
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516B, SPF343, SPS343, SPT343
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516B, SPF343, SPS343, SPT343
2080823
SHUTOFF GP-AIR
3512B, 3516B, PM3516
3512B, 3516B, PM3516
2727095
SHUTOFF GP-AIR
3508, 3508B, 3508C, 3512B, 3512C, 3516B
3508, 3508B, 3508C, 3512B, 3512C, 3516B
2882762
SHUTOFF GP-AIR
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516B, 3516C, SPF343, SPT343
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516B, 3516C, SPF343, SPT343
1350180
SHUTOFF GP-AIR
3508B, 3512B, 3516, 3516B, PM3516
3508B, 3512B, 3516, 3516B, PM3516
2882765
SHUTOFF GP-AIR
3508B, 3512B
3508B, 3512B
1186677
SHUTOFF GP-AIR
3512B, 3516, 3516B
3512B, 3516, 3516B
2177747
SHUTOFF GP-AIR
3516B
3516B
1225946
SHUTOFF GP-AIR
3508, 3508B, 3512, 3512B, 3516, 3516B, SPF343, SPS343, SPT343
3508, 3508B, 3512, 3512B, 3516, 3516B, SPF343, SPS343, SPT343
5N1683
SHUTOFF GP-ELECTRICAL
3508, 3512, 3516
3508, 3512, 3516
9Y4848
SHUTOFF GP-ELECTRICAL
3406B, 3406C
3406B, 3406C
2W5203
SHUTOFF GP-ELECTRICAL
3204, 3304, 3306, 3306B
3204, 3304, 3306, 3306B
5N5338
SHUTOFF GP-CONTROL
3508, 3512, 3516
3508, 3512, 3516
1W4861
SHUTOFF GP-MANUAL
3508, 3512, 3516, 3606, 3608, 3612, 3616, 777B, 785, 789, 793, 994
3508, 3512, 3516, 3606, 3608, 3612, 3616, 777B, 785, 789, 793, 994
2882761
SHUTOFF GP-AIR
3508B, 3512, 3512B, 3512C, 3516B, SPF343, SPT343
3508B, 3512, 3512B, 3512C, 3516B, SPF343, SPT343
2131627
SHUTOFF GP-AIR
C-10, C-12
C-10, C-12
1720260
SHUTOFF GP-HYDROMECHANICAL
3508, 3512, 3516
3508, 3512, 3516
2899118
SHUTOFF GP-AIR
3508B, 3512B
3508B, 3512B
1720257
SHUTOFF GP-CONTROL
3508, 3508C, 3512, 3512B, 3516
3508, 3508C, 3512, 3512B, 3516