7C1309 SHUTOFF GP-ELECTRICAL Caterpillar parts
3126, 3508, 3508C, 3512, 3516
Rating:
Alternative (cross code) number:
CA7C1309
7C-1309
7C1309
CA7C1309
7C-1309
7C1309
GEN SET ENGINE, TRUCK ENGINE,
Compatible equipment models: 7C1309:
Information:
SIZE="-1">Illustration 1 g03679141
Illustration 2 g03325748
P1 ECM connector (P1-40) Run/Stop 1 (P1-54) Run/Stop 2
Illustration 3 g03393083
P2 ECM connector (92) Digital return
Illustration 4 g03679162
P1 ECM connector (AA) Start/Run/Stop 1 (AB) Start/Run/Stop 2 (BC) Keyswitch
Table 2
1. Inspect the Electrical Connectors and Wiring
A. Turn the main disconnect switch to the OFF position.
B. Thoroughly inspect the connectors for the stop switches and the J1/P1 ECM connector.
a. Check for a loose connection or check for poor connections at the connector for the stop switches.
b. Check connections between the stop switches and the ECM.
Refer to Troubleshooting, "Electrical Connectors - Inspect" for information related to inspecting the electrical connectors and wiring.
C. Perform a
45 N (10 lb) pull test on each of the wires that are associated with the circuit for the stop switches.
D. Check the allen head screw for each of the ECM connectors for the proper torque.
Refer to Troubleshooting, "Electrical Connectors - Inspect" for the correct torque values.
E. Check the harness and wiring for abrasion and for pinch points from the stop switches to the ECM.
   
Connectors and Wiring
    Result: The connectors and the wiring appear to be OK.
Proceed to Test Step 2.
Result: There is a problem in the connectors and/or the wiring.
Repair: Repair the connectors or the wiring. Ensure that all of the seals for the connectors are properly in place and ensure that the connectors are coupled.
Verify that the repair eliminated the problem.
   
2. Check the Status of the Switch-on Caterpillar Electronic Technician (ET)
A. Connect Caterpillar Electronic Technician (ET) to the service tool connector.
B. Restore the electrical power to the ECM.
C. Monitor the status of the start/run/stop switch-on Cat ET.
D. Turn the start/run/stop switch to the STOP position.
E. Turn the start/run/stop switch to the START position.
F. Turn the start/run/stop switch to the STOP position.
   
ECS Status
    Result: The status for the switch is correct in both the START and STOP positions. A diagnostic code for the switch is not active.
Repair: The switch appears to be operating correctly. There may be an intermittent problem in the harness or in a connector.
For information related to identifying intermittent electrical problems, refer to Troubleshooting, "Electrical Connectors - Inspect".
Verify that the repair eliminated the problem.
Result: The parameter for the switch is not correct in either the STOP or the START positions.
Proceed to Test Step 3.
   
3. Check the
Illustration 2 g03325748
P1 ECM connector (P1-40) Run/Stop 1 (P1-54) Run/Stop 2
Illustration 3 g03393083
P2 ECM connector (92) Digital return
Illustration 4 g03679162
P1 ECM connector (AA) Start/Run/Stop 1 (AB) Start/Run/Stop 2 (BC) Keyswitch
Table 2
1. Inspect the Electrical Connectors and Wiring
A. Turn the main disconnect switch to the OFF position.
B. Thoroughly inspect the connectors for the stop switches and the J1/P1 ECM connector.
a. Check for a loose connection or check for poor connections at the connector for the stop switches.
b. Check connections between the stop switches and the ECM.
Refer to Troubleshooting, "Electrical Connectors - Inspect" for information related to inspecting the electrical connectors and wiring.
C. Perform a
45 N (10 lb) pull test on each of the wires that are associated with the circuit for the stop switches.
D. Check the allen head screw for each of the ECM connectors for the proper torque.
Refer to Troubleshooting, "Electrical Connectors - Inspect" for the correct torque values.
E. Check the harness and wiring for abrasion and for pinch points from the stop switches to the ECM.
   
Connectors and Wiring
    Result: The connectors and the wiring appear to be OK.
Proceed to Test Step 2.
Result: There is a problem in the connectors and/or the wiring.
Repair: Repair the connectors or the wiring. Ensure that all of the seals for the connectors are properly in place and ensure that the connectors are coupled.
Verify that the repair eliminated the problem.
   
2. Check the Status of the Switch-on Caterpillar Electronic Technician (ET)
A. Connect Caterpillar Electronic Technician (ET) to the service tool connector.
B. Restore the electrical power to the ECM.
C. Monitor the status of the start/run/stop switch-on Cat ET.
D. Turn the start/run/stop switch to the STOP position.
E. Turn the start/run/stop switch to the START position.
F. Turn the start/run/stop switch to the STOP position.
   
ECS Status
    Result: The status for the switch is correct in both the START and STOP positions. A diagnostic code for the switch is not active.
Repair: The switch appears to be operating correctly. There may be an intermittent problem in the harness or in a connector.
For information related to identifying intermittent electrical problems, refer to Troubleshooting, "Electrical Connectors - Inspect".
Verify that the repair eliminated the problem.
Result: The parameter for the switch is not correct in either the STOP or the START positions.
Proceed to Test Step 3.
   
3. Check the
Caterpillar SIS machinery equipment:
Caterpillar SIS
3512 GENERATOR SET ENGINE 24Z01317-UP »
7C-1309
SHUTOFF GP-ELECTRICAL
3508 GENERATOR SET ENGINE 23Z01023-03488 »
7C-1309
SHUTOFF GP-ELECTRICAL
3516 Generator Set Engine 25Z00684-02188 »
7C-1309
SHUTOFF GP-ELECTRICAL
3508 GENERATOR SET ENGINE 1ZF00001-UP »
7C-1309
SHUTOFF GP-ELECTRICAL
3512 ENGINE GENERATOR SET 3YF00001-UP »
7C-1309
SHUTOFF GP-ELECTRICAL
3516 Generator Set Engine 4XF00001-UP »
7C-1309
SHUTOFF GP-ELECTRICAL
3516 Generator Set Engine 5SJ00001-UP »
7C-1309
SHUTOFF GP-ELECTRICAL
3508 Generator Set Engine 70Z00757-UP »
7C-1309
SHUTOFF GP-ELECTRICAL
3508 Generator Set Engine (High Speed) 23Z03489-UP »
7C-1309
SHUTOFF GP-ELECTRICAL
3512 Generator Set Engine 24Z04366-UP »
7C-1309
SHUTOFF GP-ELECTRICAL
3512 Generator Set Engine 67Z00772-UP »
7C-1309
SHUTOFF GP-ELECTRICAL
3516 Generator Set Engine 25Z02189-UP »
7C-1309
SHUTOFF GP-ELECTRICAL
3516 Generator Set Engine 73Z00808-UP »
7C-1309
SHUTOFF GP-ELECTRICAL
3508 Marine Generator Set Military 8TL00001-UP »
7C-1309
SHUTOFF GP-ELECTRICAL
3508 Generator Set CNF00001-UP »
7C-1309
SHUTOFF GP-ELECTRICAL
3512 Generator Set CMJ00001-UP »
7C-1309
SHUTOFF GP-ELECTRICAL
3516 Generator Set Oil Field Land Rig PTD00001-UP »
7C-1309
SHUTOFF GP-ELECTRICAL
3512 Generator Set Oil Field Land Rig PTG00001-UP »
7C-1309
SHUTOFF GP-ELECTRICAL
3512 Generator Set Oil Field Land Rig PTH00001-UP »
7C-1309
SHUTOFF GP-ELECTRICAL
3508 Generator Set Oil Field Land Rig PTK00001-UP »
7C-1309
SHUTOFF GP-ELECTRICAL
3516 Generator Set Oil Field Land Rig RKT00001-UP »
7C-1309
SHUTOFF GP-ELECTRICAL
Cat SIS web machinery list:
Parts shutoff Caterpillar catalog:
1117760
SHUTOFF GP-ELECTRICAL
3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3408C, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B, C15, C18, C9, G3304, G3306, G3306B, G3406, G3408, G3408B, G3412, G3508, G3512, G351...
3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3408C, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B, C15, C18, C9, G3304, G3306, G3306B, G3406, G3408, G3408B, G3412, G3508, G3512, G351...
5N6051
SHUTOFF GP-CONTROL
3508, 3512, 3516
3508, 3512, 3516
1W1270
SHUTOFF GP-AIR
3508, 3516
3508, 3516
5N8561
SHUTOFF GP-ELECTRICAL
3508, 3516
3508, 3516
2W6123
SHUTOFF GP-ELECTRICAL
3512, 3516
3512, 3516
7W8911
SHUTOFF GP-ELECTRICAL
3512, 3516
3512, 3516
4W6977
SHUTOFF GP-HYDRAMECHANICAL
3508, 3508C
3508, 3508C
1720262
SHUTOFF GP-CONTROL
3508, 3512, 3516
3508, 3512, 3516
7W9359
SHUTOFF AR-ELECTRICAL
3126, 3508, 3508B, 3512
3126, 3508, 3508B, 3512
1123593
SHUTOFF GP-AIR
3508B, 3512B, 3516, 3516B
3508B, 3512B, 3516, 3516B
1186677
SHUTOFF GP-AIR
3512B, 3516, 3516B
3512B, 3516, 3516B
5N9557
SHUTOFF GP-ELECTRICAL
G3408, G3412
G3408, G3412
7C5274
SHUTOFF GP-ELECTRICAL
3508, 3512, 3516
3508, 3512, 3516
1117761
SHUTOFF GP-ELECTRICAL
3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3408C, 3412, 3412C, 3508, 3512, 3516, C15, C18, G3304, G3306, G3306B, G3406, G3408, G3408B, G3412, G3508, G3512, G3516, PM3412, SR4
3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3408C, 3412, 3412C, 3508, 3512, 3516, C15, C18, G3304, G3306, G3306B, G3406, G3408, G3408B, G3412, G3508, G3512, G3516, PM3412, SR4
5N6050
SHUTOFF GP-CONTROL
3508, 3512, 3516
3508, 3512, 3516
7C5238
SHUTOFF GP-ELECTRICAL
3508, 3512, 3516
3508, 3512, 3516
7E7395
SHUTOFF GP-AIR
3508, 3512
3508, 3512
1507891
SHUTOFF GP-AIR
3606, 3608, C280-6, C280-8, G3606, G3606B, G3608
3606, 3608, C280-6, C280-8, G3606, G3606B, G3608
7W3954
SHUTOFF GP-ELECTRICAL
3606, 3608, 3612, 3616
3606, 3608, 3612, 3616
7W6349
SHUTOFF GP-ELECTRICAL
3508, 3512, 3516
3508, 3512, 3516
2468477
SHUTOFF GP-AIR
3408C, C18
3408C, C18
2W8196
SHUTOFF GP-ELECTRICAL
3304, 3306, 3406B
3304, 3306, 3406B