Operation Description:The spare analog inputs are connected to resistive type sensors either on the engine, generator, or supporting systems. The EMCP 3 converts the resistive sensor values into levels, temperatures, and pressures depending on how the input is configured. Six programmable thresholds are provided. The thresholds include both high and low for each of the three supported data types. The appropriate thresholds are selected based on the spare analog input type configuration set points. The EMCP 3 will also detect sensor diagnostics for shorted high and shorted low conditions.An active spare analog input can be programmed to cause an alarm or a shutdown. Refer to System Operation, RENR7902, "Spare Analog Input Programming" for information for programming spare inputs.The analog input code is generated when the measured spare analog input value goes above or below the programmed threshold for a specified duration.Test Step 1. PERFORM THE INITIAL CHECK.
Use the Cat ET in order to check for active diagnostic codes on the engine ECM. If any codes are present, first, correct the problem that caused the codes.Expected Result:No other diagnostic codes or indicators are active on the engine ECM.Results:
OK - No other diagnostic codes or indicators are active. Proceed to Test Step 2.
NOT OK - Another engine ECM diagnostic code is active.Repair: Exit the procedure. Troubleshoot the active code or indicator. Refer to the engine troubleshooting manual for your particular generator set.STOPTest Step 2. CHECK THE SET POINTS.
View the spare analog Input set points. Make a note of the set points. See Testing and Adjusting, RENR7902, "Electronic Control Module (Generator Set) - Configure". Compare the set points against the default set points of the particular generator set.Expected Result:The set points are correct.Results:
OK - The set points are correct for your particular generator set. Proceed to Test Step 3.
NOT OK - The set points are NOT correct.Repair: Change the set points to the desired values. Reset the generator set. Resume normal operation and verify that the problem has been corrected.STOPTest Step 3. CHECK THE ANALOG INPUT DEVICE WIRING.
Check the wiring to the corresponding spare analog input for an unwanted short circuit. The short can be to the battery negative ("B-"). The short can be to the battery positive terminal ("B+"). Carefully check ALL wires that are connected to any analog input for abrasion or worn spots in the insulation. Any abrasion or worn spots could cause a short. Check the wires in the generator control panel. Check the wires in the engine harness. Refer to the appropriate wiring diagrams for the circuit that is being checked. Expected Result:The wiring is correct.Results:
OK - No problems can be found with the analog input wiring. Proceed to Test Step 4.
NOT OK - The analog input wiring is defective.Repair: Repair the wiring or replace the wiring. Proceed to Test Step 4.Test Step 4. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Reset the generator set.
Operate the generator set.
Check the status of the diagnostic code.Expected
Use the Cat ET in order to check for active diagnostic codes on the engine ECM. If any codes are present, first, correct the problem that caused the codes.Expected Result:No other diagnostic codes or indicators are active on the engine ECM.Results:
OK - No other diagnostic codes or indicators are active. Proceed to Test Step 2.
NOT OK - Another engine ECM diagnostic code is active.Repair: Exit the procedure. Troubleshoot the active code or indicator. Refer to the engine troubleshooting manual for your particular generator set.STOPTest Step 2. CHECK THE SET POINTS.
View the spare analog Input set points. Make a note of the set points. See Testing and Adjusting, RENR7902, "Electronic Control Module (Generator Set) - Configure". Compare the set points against the default set points of the particular generator set.Expected Result:The set points are correct.Results:
OK - The set points are correct for your particular generator set. Proceed to Test Step 3.
NOT OK - The set points are NOT correct.Repair: Change the set points to the desired values. Reset the generator set. Resume normal operation and verify that the problem has been corrected.STOPTest Step 3. CHECK THE ANALOG INPUT DEVICE WIRING.
Check the wiring to the corresponding spare analog input for an unwanted short circuit. The short can be to the battery negative ("B-"). The short can be to the battery positive terminal ("B+"). Carefully check ALL wires that are connected to any analog input for abrasion or worn spots in the insulation. Any abrasion or worn spots could cause a short. Check the wires in the generator control panel. Check the wires in the engine harness. Refer to the appropriate wiring diagrams for the circuit that is being checked. Expected Result:The wiring is correct.Results:
OK - No problems can be found with the analog input wiring. Proceed to Test Step 4.
NOT OK - The analog input wiring is defective.Repair: Repair the wiring or replace the wiring. Proceed to Test Step 4.Test Step 4. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Reset the generator set.
Operate the generator set.
Check the status of the diagnostic code.Expected
Caterpillar SIS machinery equipment:
Caterpillar SIS
3512 GENERATOR SET ENGINE 24Z01317-UP »
7C-2187
SHUTOFF GP-ELECTRICAL
3508 GENERATOR SET ENGINE 23Z01023-03488 »
7C-2187
SHUTOFF GP-ELECTRICAL
3516 Generator Set Engine 25Z00684-02188 »
7C-2187
SHUTOFF GP-ELECTRICAL
3508 GENERATOR SET ENGINE 1ZF00001-UP »
7C-2187
SHUTOFF GP-ELECTRICAL
3512 ENGINE GENERATOR SET 3YF00001-UP »
7C-2187
SHUTOFF GP-ELECTRICAL
3516 Generator Set Engine 4XF00001-UP »
7C-2187
SHUTOFF GP-ELECTRICAL
3516 Generator Set Engine 5SJ00001-UP »
7C-2187
SHUTOFF GP-ELECTRICAL
3508 Generator Set Engine 70Z00757-UP »
7C-2187
SHUTOFF GP-ELECTRICAL
3508 Generator Set Engine (High Speed) 23Z03489-UP »
7C-2187
SHUTOFF GP-ELECTRICAL
3512 Generator Set Engine 24Z04366-UP »
7C-2187
SHUTOFF GP-ELECTRICAL
3512 Generator Set Engine 67Z00772-UP »
7C-2187
SHUTOFF GP-ELECTRICAL
3516 Generator Set Engine 25Z02189-UP »
7C-2187
SHUTOFF GP-ELECTRICAL
3516 Generator Set Engine 73Z00808-UP »
7C-2187
SHUTOFF GP-ELECTRICAL
3508 Marine Generator Set Military 8TL00001-UP »
7C-2187
SHUTOFF GP-ELECTRICAL
3508 Generator Set CNF00001-UP »
7C-2187
SHUTOFF GP-ELECTRICAL
3512 Generator Set CMJ00001-UP »
7C-2187
SHUTOFF GP-ELECTRICAL
3516 Generator Set Oil Field Land Rig PTD00001-UP »
7C-2187
SHUTOFF GP-ELECTRICAL
3512 Generator Set Oil Field Land Rig PTG00001-UP »
7C-2187
SHUTOFF GP-ELECTRICAL
3512 Generator Set Oil Field Land Rig PTH00001-UP »
7C-2187
SHUTOFF GP-ELECTRICAL
3508 Generator Set Oil Field Land Rig PTK00001-UP »
7C-2187
SHUTOFF GP-ELECTRICAL
3516 Generator Set Oil Field Land Rig RKT00001-UP »
7C-2187
SHUTOFF GP-ELECTRICAL
Caterpillar parts catalog:
Parts shutoff Caterpillar catalog:
1117760
SHUTOFF GP-ELECTRICAL
3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3408C, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B, C15, C18, C9, G3304, G3306, G3306B, G3406, G3408, G3408B, G3412, G3508, G3512, G351...
3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3408C, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B, C15, C18, C9, G3304, G3306, G3306B, G3406, G3408, G3408B, G3412, G3508, G3512, G351...
7W8912
SHUTOFF GP-ELECTRICAL
3512, 3516
3512, 3516
4W6977
SHUTOFF GP-HYDRAMECHANICAL
3508, 3508C
3508, 3508C
1720262
SHUTOFF GP-CONTROL
3508, 3512, 3516
3508, 3512, 3516
1123593
SHUTOFF GP-AIR
3508B, 3512B, 3516, 3516B
3508B, 3512B, 3516, 3516B
7W3955
SHUTOFF GP-ELECTRICAL
3508, 3512, 3516, 3606, 3608, 3612, 3616
3508, 3512, 3516, 3606, 3608, 3612, 3616
5N5608
SHUTOFF GP-CONTROL
3508, 3512, 3516
3508, 3512, 3516
1W8578
SHUTOFF & OIL FILLER GP
3508, 3512, 3516
3508, 3512, 3516
3N8881
SHUTOFF GP-MECHANICAL
3304, 3306
3304, 3306
1632586
SHUTOFF GP-AIR
3176C, 3196, C-10, C-12
3176C, 3196, C-10, C-12
2727095
SHUTOFF GP-AIR
3508, 3508B, 3508C, 3512B, 3512C, 3516B
3508, 3508B, 3508C, 3512B, 3512C, 3516B
1934652
SHUTOFF GP-AIR
3612, 3616, C280-12, C280-16
3612, 3616, C280-12, C280-16
4N9314
SHUTOFF GP-ELECTRICAL
225, 225D, 227, 229, 231D, 3160, 3208, 613B, 613C, PR-1000, PS-500
225, 225D, 227, 229, 231D, 3160, 3208, 613B, 613C, PR-1000, PS-500
3209114
SHUTOFF GP-ELECTRICAL
C0.7, C1.1, C1.5, C1.6, C2.2
C0.7, C1.1, C1.5, C1.6, C2.2
1555261
SHUTOFF GP-AIR
3512B
3512B
1W8216
SHUTOFF GP-ELECTRICAL
3304, 3306, 3406B
3304, 3306, 3406B
2882762
SHUTOFF GP-AIR
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516B, 3516C, SPF343, SPT343
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516B, 3516C, SPF343, SPT343