4445061 SLEEVE Caterpillar parts
Rating:
Alternative (cross code) number:
CA4445061
444-5061
4445061
CA4445061
444-5061
4445061
Weight: 0.12 pounds 0 kg.
Information:
Flash File 342-2512
342-2512 Communication Software Gp has been released as a direct replacement for the existing 315-0627 Communication Software Gp. The 342-2512 Communication Software Gp provides the same functionality as the 315-0627 Communication Software Gp with several new features and enhancements.New Features
An Embedded Communications Adapter is used for J1939 Flashing and Servicing.
The PL1000E Webpage now includes a "RS-485 4/2 Wire configuration" selection.
J1939 Diagnostics to Webserver is now available.
The default configuration has changed to the values that are shown in Table 1.
Table 1
Parameter     Value    
"Modbus Ports"     "Enabled"    
"Internet Protocol Addressing"     "Static Addressing"    
"IP"     "192.161.1.1"    
"Mask"     255.255.255.0    
"Gateway"     0.0.0.0    Enhancements
The "Rolling Reset Security Condition" has been removed. This removes the ".pcl" file from use when five power cycles occur within a time period of 60 seconds or less.
The resetting of the PL1000E to "Defaults Security Condition" which occurred during power cycling has been removed.
The "Custom Webpage Lockup" which occurred over time has been corrected.
The "Active Events Sustained After Power Cycle" functionality has been corrected.
The "DHCP Gateway Address" which would increase by a value of 1 in the fourth octet has been corrected.
The PL1000E will only accept configurations of the baud rate that are valid.
The ".PCL File Extension" is no longer case sensitive.
342-2512 Communication Software Gp has been released as a direct replacement for the existing 315-0627 Communication Software Gp. The 342-2512 Communication Software Gp provides the same functionality as the 315-0627 Communication Software Gp with several new features and enhancements.New Features
An Embedded Communications Adapter is used for J1939 Flashing and Servicing.
The PL1000E Webpage now includes a "RS-485 4/2 Wire configuration" selection.
J1939 Diagnostics to Webserver is now available.
The default configuration has changed to the values that are shown in Table 1.
Table 1
Parameter     Value    
"Modbus Ports"     "Enabled"    
"Internet Protocol Addressing"     "Static Addressing"    
"IP"     "192.161.1.1"    
"Mask"     255.255.255.0    
"Gateway"     0.0.0.0    Enhancements
The "Rolling Reset Security Condition" has been removed. This removes the ".pcl" file from use when five power cycles occur within a time period of 60 seconds or less.
The resetting of the PL1000E to "Defaults Security Condition" which occurred during power cycling has been removed.
The "Custom Webpage Lockup" which occurred over time has been corrected.
The "Active Events Sustained After Power Cycle" functionality has been corrected.
The "DHCP Gateway Address" which would increase by a value of 1 in the fourth octet has been corrected.
The PL1000E will only accept configurations of the baud rate that are valid.
The ".PCL File Extension" is no longer case sensitive.
Caterpillar parts catalog:
Parts sleeve Caterpillar catalog:
1308713
SLEEVE
Caterpillar
Caterpillar
1308712
SLEEVE
Caterpillar
Caterpillar
1032552
SLEEVE
Caterpillar
Caterpillar
8Y8364
SLEEVE
Caterpillar
Caterpillar
5527953
SLEEVE
Caterpillar
Caterpillar
5433734
SLEEVE-GUIDE
Caterpillar
Caterpillar
5173217
SLEEVE
Caterpillar
Caterpillar
5173211
SLEEVE
Caterpillar
Caterpillar
5173208
SLEEVE
Caterpillar
Caterpillar
4634050
SLEEVE
Caterpillar
Caterpillar
4540277
SLEEVE
Caterpillar
Caterpillar
4503479
SLEEVE
Caterpillar
Caterpillar