AVSPARE.COM
parts catalog

SOCKET-GP-YM 3256211 - Caterpillar


3256211 SOCKET-GP-YM Caterpillar parts
Rating:
9
Alternative (cross code) number:
CA3256211
325-6211
3256211
Caterpillar 3256211 SOCKET-GP-YM
Weight: 3 pounds 1 kg.

Buy SOCKET-GP-YM 3256211 Caterpillar genuine, new aftermarket tractor parts with delivery

Related part:
1313736  SOCKET-GP-YM  3256211  CL

Compare Prices: .

As an associate, we earn commssions on qualifying purchases through the links below
$35.76
 

27 Dec 2023

US: Florida-Parts-Z
7D8913 - Socket 6G1780 1313736 3256211 fits Caterpillar (CAT)
FIRST PRICE PARTS
$35.76
 

05 Dec 2023

US: Florida-Parts-Z
6G1780 - Socket 1313736 3256211 7D8913 fits Caterpillar (CAT)
FIRST PRICE PARTS
$35.76
 

07 Apr 2023

US: Florida-Parts-Z
131-3736 - Socket 6G1780 3256211 7D8913 fits Caterpillar (CAT)
FIRST PRICE PARTS
  For full view, you need register

Information:


Table 1
Specifications
Regulation 0.25% from no load to full load.
Regulator temperature drift Less than 1% for any 40 °C (72 °F) change over the ambient operating temperature range.
Volts/Hz characteristic that can be configured Two slope ranges adjustable from 1 to 10 V/Hz. Refer to regulation characteristic Illustration 1.
Regulator response time Maximum of 10 milliseconds.
Regulator sensing True RMS 3-phase sensing is standard. Single phase sensing is available. Variable sense range: 90 to 600 V.
Regulator stability The regulator maintains stable output voltage within 0.25% for total harmonic distortion of the generator output voltage waveform up to 30%. The regulator maintains stable output voltage within 0.50% for total harmonic distortion of the generator output voltage waveform up to 40%. Thee values are based on a typical 6-SCR bridge.
Telephone influence factor (TIF) Less than 50. Complies with MIL STD 461C Part 9 and VDE 0875 level N.
Fine voltage adjust range 10% of regulator sensing voltage.
Regulator voltage gain (Line loss compensation) Adjustable from 0 to 10%.
Fault detection and identification Diagnostics identify operation outside of programmed limits. Specific fault information is available even after the unit has been powered down. CAN bus only.
Harmonic tolerance For total harmonic distortion of the generator output voltage waveform up to 30%, the regulator maintains stable output voltage within 0.25%. For total harmonic distortion of the generator output voltage waveform up to 40%, the regulator maintains stable output voltage within 0.50%. These values are based on a typical 6-SCR bridge.
Reactive droop adjustment Adjustable from 0 to 10%.
Over excitation protection Shuts off generator output when excitation current exceeds normal operating currents for 10 seconds or instantaneous shutoff if output current exceeds approximately 28 A.
Ambient operating temperature −40 °C (−40 °F) to +70 °C (+ 158 °F).
Storage temperature range −40 °C (−40 °F) to +85 °C (+ 185 °F).
Power dissipation 5 W at idle, 55 W at rated output.
Shock Withstands up to 20 g (g-force ) in three mutually perpendicular planes.
Vibration Withstands 4.5 g (g-force ) at frequencies between 18 and 2000 Hz in three mutually perpendicular planes.
Salt fog 5% salt spray for 48 hours at 38 °C (100.4 °F) at 115% of the nominal operating voltage.
Weight 1.47 kg (3.24 lb.).
Electromagnetic compatibility Meets 89/336/EEC Electromagnetic Compatibility Directive.
Power supply 24 6 VDC power supply required (0.5 amp).
Conformity UL Underwriters Laboratory (UL) recognized per "Standard 508, UL File No. E97035".
CSA Certified per "Standard CAN/CSA-C22.2 No. 14-95, CSA File No. LR 23131".
CE Conforms to the following standards:
Radiated Emissions EN50081-2
Radiated Immunity (electric field) EN61000-4-3 (10 V/m)
Radiated Immunity (conducted) EN61000-4-6 (10 VRMS)
Conducted Emissions EN50081-2 (EN55011, Class A)
ESD Immunity EN50082-2 (4 kV contact, 8 kV air)
EFT Immunity EN50082-2 (2 kV coupling clamp)
Magnetic Immunity EN50082-2 (30 ARMS, 50 Hz)
Safety EN61010-1
Illustration 1 g01040043
Regulation characteristic
Table 2
Summary of Operating Parameters
Parameter Specifications
Voltage Regulation Rating 120 to 15000 V
Generator Type PM
SE
Internal Excitation (IE)
Power Input Voltage(1) Frequency Burden (Continuous)
80 to 264 V (3Ø)
100 to 280 V (1Ø) 50 to 400 Hz 1150 VA (63 VDC applications) or 1900 VA (125 VDC applications)
Output Rating Maximum Continuous Maximum Forcing (10 Seconds)
Voltage Current Voltage


Parts socket Caterpillar catalog:

Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.